United States / Build / Ecostar LLC
Ecostar LLC This is a listed roofing assembly. Listing 8180-2369:0001. This site cites ASTM E108 / UL 790. Match the model and orientation.
Listing lapsed. A listing this record relied on is no longer in the live OSFM BML as of 2026-08-25. It may have expired, been withdrawn, or been renumbered — confirm on GOVmotus before specifying. This status is computed from the cited evidence by the published rule, never hand-assigned.
◆ CAL FIRE BML 8180-2369:0001 · lapsed
Ecostar LLC listing 8180-2369:0001 in OSFM category 8180. Molded plastic shingles, Empire Beveled Edge Slate, Empire Beaver Tail Slate, Empire Traditional Slate, Empire Chisel Point Slate, Empire Shake, Empire Plus Shake, Empire Niagara Slate, Empire Niagara Shake, and Victorian Fish-Scale. Refer to listee's data sheet for additional detailed product description and operational considerations.
Kind: listed-assembly.
Brand: Ecostar LLC . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-23. JSON (CC BY 4.0)
Can you use it here?
Enter your ZIP to see which local requirement this meets.
Specification notes Not present in the live OSFM BML as of 2026-08-25, though it appeared in the 2025-09-02 WUI handbook. The listing may have expired, been withdrawn, or been renumbered. Do not specify against the OSFM listing without confirming on GOVmotus. Listing is from the OSFM WUI handbook. Confirm the live GOVmotus record and the exact model before specification. Can I use this here How this product meets each requirement (33)
Requirement constraints (33)
Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
ORSC R327 Class B roof floor undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented
ORSC R327 roof-profile closure undocumented Field Required Documented value State Assembly role Assembly role = roof profile closure Not documented undocumented
ORSC R327 valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of galvanized steel Not documented undocumented
Austin Zone C Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
IWUIC Class 1–2 Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
IWUIC roof-profile eave closure undocumented Field Required Documented value State Assembly role Assembly role = roof profile closure Not documented undocumented
IWUIC valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of galvanized steel Not documented undocumented
California Class A roof test path undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
California roof-valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of aluminum, copper, galvanized steel, stainless steel, steel, zinc Not documented undocumented
IWUIC Class 3 Class B roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
Colorado CWRC Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
Colorado CWRC valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of galvanized steel Not documented undocumented
2018 IWUIC Class 1 Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2018 IWUIC Class 2 Class B roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2018 IWUIC Class 3 Class C roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b, class c Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2018 IWUIC valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of galvanized steel Not documented undocumented
Kittitas high/extreme Class A roof covering undocumented Field Required Documented value State Assembly role Assembly role = roof covering Not documented undocumented Fire rating Fire rating = class a Not documented undocumented
Kittitas low/general Class C roof floor undocumented Field Required Documented value State Assembly role Assembly role = roof covering Not documented undocumented Fire rating Fire rating is one of class a, class b, class c Not documented undocumented
Kittitas moderate Class B roof floor undocumented Field Required Documented value State Assembly role Assembly role = roof covering Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented
2021 IWUIC Class 1–2 Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2021 IWUIC Class 3 Class B roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2021 IWUIC valley flashing undocumented Field Required Documented value State Assembly role Assembly role = valley flashing Not documented undocumented Sheet gauge Sheet gauge ≤ 26 Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Material Material is one of galvanized steel Not documented undocumented
Prescott Class 3 Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented Test standard Test standard is one of astm e108, ul 790 Not documented undocumented
2006 Utah UWUI Class 1 Class A roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating = class a Not documented undocumented
2006 Utah UWUI noncombustible roof covering undocumented Field Required Documented value State Assembly role Assembly role = roof covering Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 2 Class B roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b Not documented undocumented
2006 Utah UWUI Class 3 Class C roof undocumented Field Required Documented value State Assembly role Assembly role = roof assembly Not documented undocumented Fire rating Fire rating is one of class a, class b, class c Not documented undocumented
2006 Utah UWUI Class A roof covering undocumented Field Required Documented value State Assembly role Assembly role = roof covering Not documented undocumented Fire rating Fire rating = class a Not documented undocumented
Ecostar LLC. FireApproved. https://fireapproved.com/materials/ecostar-llc/. Last verified 2026-08-23. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.