{"id":"ecostar-llc","license":"CC-BY-4.0","data":{"name":"Ecostar LLC","summary":"Ecostar LLC listing 8180-2369:0001 in OSFM category 8180. Molded plastic shingles, Empire Beveled Edge Slate, Empire Beaver Tail Slate, Empire Traditional Slate, Empire Chisel Point Slate, Empire Shake, Empire Plus Shake, Empire Niagara Slate, Empire Niagara Shake, and Victorian Fish-Scale. Refer to listee's data sheet for additional detailed product description and operational considerations.","productKind":"listed-assembly","brand":"ecostar-llc","categories":["roofing"],"listings":[{"program":"CAL FIRE BML","listingId":"8180-2369:0001","status":"expired","url":"https://calfire.govmotus.org/BMLSearch/Index","dated":"2026-08-25T00:00:00.000Z","notes":"From 2025 OSFM WUI Listed Products Handbook (2025-09-02). Category 8180. UL 790; Class A Roof Covering"}],"complianceStatus":"lapsed","complianceAsOf":"2026-08-25T00:00:00.000Z","standards":["astm-e108-ul-790","cal-fire-bml"],"warnings":["Not present in the live OSFM BML as of 2026-08-25, though it appeared in the 2025-09-02 WUI handbook. The listing may have expired, been withdrawn, or been renumbered. Do not specify against the OSFM listing without confirming on GOVmotus.","Listing is from the OSFM WUI handbook. Confirm the live GOVmotus record and the exact model before specification.","OSFM listing is not a permit. The authority having jurisdiction decides."],"sources":[{"title":"2025 OSFM WUI Listed Products Handbook (2 September 2025)","url":"https://osfm.fire.ca.gov/what-we-do/fire-engineering-and-investigations/building-materials-listing","publisher":"CAL FIRE OSFM","sourceType":"official","accessedOn":"2026-08-23T00:00:00.000Z","documentDate":"2025-09-02T00:00:00.000Z"},{"title":"OSFM Building Materials Listing search","url":"https://calfire.govmotus.org/BMLSearch/Index","publisher":"CAL FIRE OSFM","sourceType":"listing-body","accessedOn":"2026-08-23T00:00:00.000Z"}],"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-23T00:00:00.000Z","featured":false,"sponsored":false},"resolveAt":{"us-ak":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-al":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ar":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-flagstaff":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-prescott":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-prescott","title":"Prescott 2024 IWUIC application","placeId":"us-az-prescott","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","sourceUrl":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-05-12","map":{"status":"official-map-required-not-located","summary":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for Prescott Class 3 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-prescott-class-3-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Prescott 2024 IWUIC application: Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application"},{"kind":"info","text":"Local scope: This Class A roof path applies only after the City assigns IR1 or IR2 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Local scope: This roof-profile closure applies after the City assigns IR1, IR2, or IR3 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Local scope: This valley-flashing path applies after the City assigns IR1, IR2, or IR3 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Local scope: Prescott's local Class A replacement applies only after the City assigns IR3 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-prescott-class-3-class-a-roof-assembly","shortName":"Prescott Class 3 Class A roof","href":"/requirements/iwuic-2024-prescott-class-3-class-a-roof-assembly/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-az-sedona":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ca":{"verdict":"unknown","application":{"applicationId":"cwuic-2025-california","title":"California 2025 CWUIC mapped-area application","placeId":"us-ca","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","sourceUrl":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","unresolvedPredicates":["official-hazard-map","project-type","official-confirmation"],"effectiveOn":"2026-01-01","map":{"status":"linked-official-tool","summary":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","url":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for California Class A roof test path: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/cwuic-2025-class-a-roof-test-path/"},{"kind":"check","text":"Still undocumented for California roof-profile closures: Assembly role = roof profile closure.","href":"/requirements/cwuic-2025-roof-profile-closures/"},{"kind":"check","text":"Still undocumented for California roof-valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of aluminum, copper, galvanized steel, stainless steel, steel, zinc.","href":"/requirements/cwuic-2025-roof-valley-flashing/"},{"kind":"application","text":"California 2025 CWUIC mapped-area application: California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application"},{"kind":"info","text":"Local scope: This tested roof-assembly path applies only after the official map, permit facts, local amendments, and enforcing agency place the new building within Chapter 5.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland"},{"kind":"info","text":"Local scope: This roof-profile closure applies only after the official map, permit facts, roof profile and deck, local amendments, and enforcing agency place the new building within Chapter 5.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland"},{"kind":"info","text":"Local scope: This roof-valley metal path applies only after the official map, permit facts, full underlayment detail, local amendments, and enforcing agency place the new building within Chapter 5.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland"},{"kind":"info","text":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","href":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"cwuic-2025-class-a-roof-test-path","shortName":"California Class A roof test path","href":"/requirements/cwuic-2025-class-a-roof-test-path/","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"cwuic-2025-roof-profile-closures","shortName":"California roof-profile closures","href":"/requirements/cwuic-2025-roof-profile-closures/","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"cwuic-2025-roof-valley-flashing","shortName":"California roof-valley flashing","href":"/requirements/cwuic-2025-roof-valley-flashing/","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["aluminum","copper","galvanized-steel","stainless-steel","steel","zinc"],"state":"undocumented"}]}]},"us-co":{"verdict":"unknown","application":{"applicationId":"cwrc-2025-colorado","title":"Colorado 2025 CWRC local-adoption path","placeId":"us-co","geographicScope":"mapped-area","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","sourceUrl":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","unresolvedPredicates":["local-adoption","official-hazard-map","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for Colorado CWRC Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/cwrc-2025-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for Colorado CWRC roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/cwrc-2025-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for Colorado CWRC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/cwrc-2025-roof-valley-flashing/"},{"kind":"application","text":"Colorado 2025 CWRC local-adoption path: Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","href":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"cwrc-2025-class-a-roof-assembly","shortName":"Colorado CWRC Class A roof","href":"/requirements/cwrc-2025-class-a-roof-assembly/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"cwrc-2025-roof-profile-closure","shortName":"Colorado CWRC roof-profile closure","href":"/requirements/cwrc-2025-roof-profile-closure/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"cwrc-2025-roof-valley-flashing","shortName":"Colorado CWRC valley flashing","href":"/requirements/cwrc-2025-roof-valley-flashing/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-ct":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-dc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-de":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-fl":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ga":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-hi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ia":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-boise":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-eagle":{"verdict":"unknown","application":{"applicationId":"iwuic-2018-eagle","title":"Eagle 2018 IWUIC overlay application","placeId":"us-id-eagle","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","sourceUrl":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"linked-official-tool","summary":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","url":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for 2018 IWUIC Class 1 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2018-class-1-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2018 IWUIC Class 2 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2018-class-2-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2018 IWUIC Class 3 Class C roof: Assembly role = roof assembly; Fire rating is one of class a, class b, class c; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2018-class-3-class-c-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2018 IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2018-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for 2018 IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2018-roof-valley-flashing/"},{"kind":"application","text":"Eagle 2018 IWUIC overlay application: Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application"},{"kind":"info","text":"Local scope: The Class A roof path applies only when the official 2018 IWUIC Table 503.1 outcome includes IR1 construction.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Local scope: The Class B-or-better roof path applies only when the official 2018 IWUIC Table 503.1 outcome includes IR2 construction.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Local scope: The Class C-or-better roof path applies only when the official 2018 IWUIC Table 503.1 outcome includes IR3 construction.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Local scope: The roof-profile closure path applies when the official Table 503.1 outcome includes IR1, IR2, or IR3 construction; this row does not project the table's other outcomes.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Local scope: The valley-flashing path applies when the official Table 503.1 outcome includes IR1, IR2, or IR3 construction; this row does not project the table's other outcomes.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","href":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2018-class-1-class-a-roof-assembly","shortName":"2018 IWUIC Class 1 Class A roof","href":"/requirements/iwuic-2018-class-1-class-a-roof-assembly/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2018-class-2-class-b-roof-assembly","shortName":"2018 IWUIC Class 2 Class B roof","href":"/requirements/iwuic-2018-class-2-class-b-roof-assembly/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2018-class-3-class-c-roof-assembly","shortName":"2018 IWUIC Class 3 Class C roof","href":"/requirements/iwuic-2018-class-3-class-c-roof-assembly/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b","class-c"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2018-roof-profile-closure","shortName":"2018 IWUIC roof-profile eave closure","href":"/requirements/iwuic-2018-roof-profile-closure/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2018-roof-valley-flashing","shortName":"2018 IWUIC valley flashing","href":"/requirements/iwuic-2018-roof-valley-flashing/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-il":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-in":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ks":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ky":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-la":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ma":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-md":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-me":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mo":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ms":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ne":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nj":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm-santa-fe":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv-clark":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-clark-county","title":"Clark County 2024 IWUIC application","placeId":"us-nv-clark","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","sourceUrl":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-12-02","effectiveOn":"2026-01-01","map":{"status":"official-map-required-not-located","summary":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC Class 3 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Clark County 2024 IWUIC application: Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This Class A roof path applies only when the County assigns IR1 or IR2 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Local scope: This Class B roof path applies only when the County assigns IR3 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Local scope: This roof-profile closure applies after the County assigns IR1, IR2, or IR3 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Local scope: This valley-flashing path applies after the County assigns IR1, IR2, or IR3 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-class-3-class-b-roof-assembly","shortName":"IWUIC Class 3 Class B roof","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-nv-washoe":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-washoe-county","title":"Washoe County 2024 IWUIC Chapter 5 application","placeId":"us-nv-washoe","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","sourceUrl":"https://www.washoecounty.gov/building/getting_started/building_codes.php","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-06-10","effectiveOn":"2025-07-01","map":{"status":"linked-official-tool","summary":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","url":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC Class 3 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Washoe County 2024 IWUIC Chapter 5 application: Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application"},{"kind":"info","text":"Local scope: This Class A roof path applies only after the County and fire district inputs route the project to IR1 or IR2 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Local scope: This Class B roof path applies only after the County and fire district inputs route the project to IR3 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Local scope: This roof-profile closure applies after the County and fire district inputs route the project to IR1, IR2, or IR3 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Local scope: This valley-flashing path applies after the County and fire district inputs route the project to IR1, IR2, or IR3 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","href":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-class-3-class-b-roof-assembly","shortName":"IWUIC Class 3 Class B roof","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-ny":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-oh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ok":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-or":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-ashland":{"verdict":"unknown","application":{"applicationId":"orsc-r327-ashland","title":"Ashland ORSC R327 adoption","placeId":"us-or-ashland","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","sourceUrl":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","unresolvedPredicates":["project-type","official-confirmation"],"adoptedOn":"2021-06-01","effectiveOn":"2021-10-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Ashland ORSC R327 adoption: Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","href":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption"},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-bend":{"verdict":"unknown","application":{"applicationId":"orsc-r327-bend","title":"Bend ORSC R327 application","placeId":"us-or-bend","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","sourceUrl":"https://bend.municipal.codes/BC/9.10.010","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-04-15"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Bend ORSC R327 application: Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","href":"https://bend.municipal.codes/BC/9.10.010","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-deschutes":{"verdict":"unknown","application":{"applicationId":"orsc-r327-deschutes","title":"Deschutes County ORSC R327 application","placeId":"us-or-deschutes","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","sourceUrl":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2026-01-28","effectiveOn":"2026-04-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Deschutes County ORSC R327 application: Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","href":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-grants-pass":{"verdict":"unknown","application":{"applicationId":"orsc-r327-grants-pass","title":"Grants Pass ORSC R327 adoption","placeId":"us-or-grants-pass","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","sourceUrl":"https://www.grantspassoregon.gov/DocumentCenter/View/42","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-06-02"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Grants Pass ORSC R327 adoption: Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","href":"https://www.grantspassoregon.gov/DocumentCenter/View/42","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-lincoln":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-marion":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-medford":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-portland":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-redmond":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-sisters":{"verdict":"unknown","application":{"applicationId":"orsc-r327-sisters","title":"Sisters ORSC R327 application","placeId":"us-or-sisters","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","sourceUrl":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2025-11-19","effectiveOn":"2026-04-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Sisters ORSC R327 application: Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","href":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-or-yamhill":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for ORSC R327 Class B roof floor: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/orsc-r327-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for ORSC R327 roof-profile closure: Assembly role = roof profile closure.","href":"/requirements/orsc-r327-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for ORSC R327 valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/orsc-r327-roof-valley-flashing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-class-b-roof-assembly","shortName":"ORSC R327 Class B roof floor","href":"/requirements/orsc-r327-class-b-roof-assembly/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"orsc-r327-roof-profile-closure","shortName":"ORSC R327 roof-profile closure","href":"/requirements/orsc-r327-roof-profile-closure/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"orsc-r327-roof-valley-flashing","shortName":"ORSC R327 valley flashing","href":"/requirements/orsc-r327-roof-valley-flashing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-pa":{"verdict":"unknown","application":{"applicationId":"iwuic-2021-pennsylvania","title":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","placeId":"us-pa","geographicScope":"statewide","status":"active","requirementCoverage":"partial","scopeSummary":"34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","sourceUrl":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","unresolvedPredicates":["official-hazard-map","official-hazard-class","project-type","official-confirmation"],"effectiveOn":"2026-01-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for 2021 IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2021-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2021 IWUIC Class 3 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2021-class-3-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2021 IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2021-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for 2021 IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2021-roof-valley-flashing/"},{"kind":"application","text":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021: 34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021"},{"kind":"info","text":"Local scope: This Class A roof path applies only after official review assigns Class 1 or Class 2 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"info","text":"Local scope: This Class B-or-better roof path applies only after official review assigns Class 3 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"info","text":"Local scope: This roof-profile path applies after official review assigns Class 1, Class 2, or Class 3 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"info","text":"Local scope: This valley-flashing path applies after official review assigns Class 1, Class 2, or Class 3 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2021-class-1-2-class-a-roof-assembly","shortName":"2021 IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2021-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2021-class-3-class-b-roof-assembly","shortName":"2021 IWUIC Class 3 Class B roof","href":"/requirements/iwuic-2021-class-3-class-b-roof-assembly/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2021-roof-profile-closure","shortName":"2021 IWUIC roof-profile eave closure","href":"/requirements/iwuic-2021-roof-profile-closure/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2021-roof-valley-flashing","shortName":"2021 IWUIC valley flashing","href":"/requirements/iwuic-2021-roof-valley-flashing/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-ri":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx-austin":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-austin","title":"Austin 2024 IWUIC proximity-zone application","placeId":"us-tx-austin","geographicScope":"authority-area","status":"active","requirementCoverage":"complete","scopeSummary":"Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","sourceUrl":"https://services.austintexas.gov/edims/document.cfm?id=451971","unresolvedPredicates":["official-boundary","official-hazard-map","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-04-10","effectiveOn":"2025-07-10","map":{"status":"linked-official-tool","summary":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","url":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for Austin Zone C Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-austin-zone-c-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Austin 2024 IWUIC proximity-zone application: Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application"},{"kind":"info","text":"Local scope: The unchanged Class A roof atom is joined only for Austin Proximity Zones A and B.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Local scope: The roof-profile closure atom is retained across Austin Proximity Zones A, B, and C.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Local scope: The metal valley-flashing atom is retained across all zones, with local woven-valley alternatives remaining separate.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Local scope: Austin replaces the model Class 3 Class B minimum with a Class A roof assembly in Zone C.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","href":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-austin-zone-c-class-a-roof-assembly","shortName":"Austin Zone C Class A roof","href":"/requirements/iwuic-2024-austin-zone-c-class-a-roof-assembly/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-ut":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ut-salt-lake-city":{"verdict":"unknown","application":{"applicationId":"utah-uwui-2006-salt-lake-city","title":"Salt Lake City 2006 Utah UWUI application","placeId":"us-ut-salt-lake-city","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","sourceUrl":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"official-map-required-not-located","summary":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1 Class A roof: Assembly role = roof assembly; Fire rating = class a.","href":"/requirements/utah-uwui-2006-class-1-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI noncombustible roof covering: Assembly role = roof covering; Noncombustible = Yes.","href":"/requirements/utah-uwui-2006-class-2-3-noncombustible-roof-covering/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 2 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/utah-uwui-2006-class-2-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 3 Class C roof: Assembly role = roof assembly; Fire rating is one of class a, class b, class c.","href":"/requirements/utah-uwui-2006-class-3-class-c-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class A roof covering: Assembly role = roof covering; Fire rating = class a.","href":"/requirements/utah-uwui-2006-class-a-roof-covering/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/utah-uwui-2006-roof-profile-closure/"},{"kind":"application","text":"Salt Lake City 2006 Utah UWUI application: Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: The Class A roof-covering path appears in IR1, IR2, and IR3; the official Table 503.1 outcome still decides which class applies.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The Class A roof-assembly path applies only when the official Table 503.1 outcome includes IR1 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The Class B-or-better roof-assembly path applies only when the official Table 503.1 outcome includes IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The Class C-or-better roof-assembly path applies only when the official Table 503.1 outcome includes IR3 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The approved noncombustible roof-covering alternative appears in IR2 and IR3, subject to official approval.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The eave-end roof-profile firestopping path appears in IR1, IR2, and IR3.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-class-a-roof-assembly","shortName":"2006 Utah UWUI Class 1 Class A roof","href":"/requirements/utah-uwui-2006-class-1-class-a-roof-assembly/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-2-3-noncombustible-roof-covering","shortName":"2006 Utah UWUI noncombustible roof covering","href":"/requirements/utah-uwui-2006-class-2-3-noncombustible-roof-covering/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-2-class-b-roof-assembly","shortName":"2006 Utah UWUI Class 2 Class B roof","href":"/requirements/utah-uwui-2006-class-2-class-b-roof-assembly/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-3-class-c-roof-assembly","shortName":"2006 Utah UWUI Class 3 Class C roof","href":"/requirements/utah-uwui-2006-class-3-class-c-roof-assembly/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b","class-c"],"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-a-roof-covering","shortName":"2006 Utah UWUI Class A roof covering","href":"/requirements/utah-uwui-2006-class-a-roof-covering/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"utah-uwui-2006-roof-profile-closure","shortName":"2006 Utah UWUI roof-profile eave closure","href":"/requirements/utah-uwui-2006-roof-profile-closure/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]}]},"us-ut-taylorsville":{"verdict":"unknown","application":{"applicationId":"utah-uwui-2006-taylorsville","title":"Taylorsville 2006 Utah UWUI application","placeId":"us-ut-taylorsville","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","sourceUrl":"https://www.utah.gov/pmn/files/1368799.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","official-confirmation"],"adoptedOn":"2025-12-17","effectiveOn":"2025-12-18","map":{"status":"linked-official-tool","summary":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","url":"https://www.utah.gov/pmn/files/1368799.pdf"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1 Class A roof: Assembly role = roof assembly; Fire rating = class a.","href":"/requirements/utah-uwui-2006-class-1-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI noncombustible roof covering: Assembly role = roof covering; Noncombustible = Yes.","href":"/requirements/utah-uwui-2006-class-2-3-noncombustible-roof-covering/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 2 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b.","href":"/requirements/utah-uwui-2006-class-2-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 3 Class C roof: Assembly role = roof assembly; Fire rating is one of class a, class b, class c.","href":"/requirements/utah-uwui-2006-class-3-class-c-roof-assembly/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class A roof covering: Assembly role = roof covering; Fire rating = class a.","href":"/requirements/utah-uwui-2006-class-a-roof-covering/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/utah-uwui-2006-roof-profile-closure/"},{"kind":"application","text":"Taylorsville 2006 Utah UWUI application: Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","href":"https://www.utah.gov/pmn/files/1368799.pdf","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: The Class A roof-covering path appears in IR1, IR2, and IR3; the official Table 503.1 outcome still decides which class applies.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The Class A roof-assembly path applies only when the official Table 503.1 outcome includes IR1 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The Class B-or-better roof-assembly path applies only when the official Table 503.1 outcome includes IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The Class C-or-better roof-assembly path applies only when the official Table 503.1 outcome includes IR3 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The approved noncombustible roof-covering alternative appears in IR2 and IR3, subject to official approval.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The eave-end roof-profile firestopping path appears in IR1, IR2, and IR3.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-class-a-roof-assembly","shortName":"2006 Utah UWUI Class 1 Class A roof","href":"/requirements/utah-uwui-2006-class-1-class-a-roof-assembly/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-2-3-noncombustible-roof-covering","shortName":"2006 Utah UWUI noncombustible roof covering","href":"/requirements/utah-uwui-2006-class-2-3-noncombustible-roof-covering/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-2-class-b-roof-assembly","shortName":"2006 Utah UWUI Class 2 Class B roof","href":"/requirements/utah-uwui-2006-class-2-class-b-roof-assembly/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-3-class-c-roof-assembly","shortName":"2006 Utah UWUI Class 3 Class C roof","href":"/requirements/utah-uwui-2006-class-3-class-c-roof-assembly/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b","class-c"],"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-a-roof-covering","shortName":"2006 Utah UWUI Class A roof covering","href":"/requirements/utah-uwui-2006-class-a-roof-covering/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"utah-uwui-2006-roof-profile-closure","shortName":"2006 Utah UWUI roof-profile eave closure","href":"/requirements/utah-uwui-2006-roof-profile-closure/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]}]},"us-va":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-vt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa-kittitas":{"verdict":"unknown","application":{"applicationId":"kcc-wui-roof-kittitas-county","title":"Kittitas County WUI and locally printed construction application","placeId":"us-wa-kittitas","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","sourceUrl":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","unresolvedPredicates":["official-boundary","fire-department-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-03-02","map":{"status":"declared-authority-wide","summary":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for Kittitas high/extreme Class A roof covering: Assembly role = roof covering; Fire rating = class a.","href":"/requirements/kcc-14-12-high-extreme-class-a-roof-covering/"},{"kind":"check","text":"Still undocumented for Kittitas low/general Class C roof floor: Assembly role = roof covering; Fire rating is one of class a, class b, class c.","href":"/requirements/kcc-14-12-low-general-class-c-roof-covering/"},{"kind":"check","text":"Still undocumented for Kittitas moderate Class B roof floor: Assembly role = roof covering; Fire rating is one of class a, class b.","href":"/requirements/kcc-14-12-moderate-class-b-roof-covering/"},{"kind":"application","text":"Kittitas County WUI and locally printed construction application: Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application"},{"kind":"info","text":"Local scope: The Class A floor applies only after the County assigns high or extreme hazard, only in an area outside a fire department; a written Fire Marshal alternative may control a specific project.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"info","text":"Local scope: The Class B-or-better floor applies only after the County assigns moderate hazard, only in an area outside a fire department; a written Fire Marshal alternative may control a specific project.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"info","text":"Local scope: Class C is the general unincorporated-County floor and the stated low-hazard floor; the Class B and Class A rows replace it where the official hazard class is higher.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"info","text":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm whether the site is outside a fire department boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"kcc-14-12-high-extreme-class-a-roof-covering","shortName":"Kittitas high/extreme Class A roof covering","href":"/requirements/kcc-14-12-high-extreme-class-a-roof-covering/","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"kcc-14-12-low-general-class-c-roof-covering","shortName":"Kittitas low/general Class C roof floor","href":"/requirements/kcc-14-12-low-general-class-c-roof-covering/","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b","class-c"],"state":"undocumented"}]},{"requirementId":"kcc-14-12-moderate-class-b-roof-covering","shortName":"Kittitas moderate Class B roof floor","href":"/requirements/kcc-14-12-moderate-class-b-roof-covering/","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-covering","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"}]}]},"us-wi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy-jackson":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-town-of-jackson","title":"Town of Jackson 2024 IWUIC application","placeId":"us-wy-jackson","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","unresolvedPredicates":["official-boundary","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2024-12-16","effectiveOn":"2025-01-01","map":{"status":"declared-authority-wide","summary":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC Class 3 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Town of Jackson 2024 IWUIC application: The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application"},{"kind":"info","text":"Local scope: This Class A roof path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Local scope: This Class B roof path applies only when Fire/EMS assigns IR3 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Local scope: This roof-profile closure applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Local scope: This valley-flashing path applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-class-3-class-b-roof-assembly","shortName":"IWUIC Class 3 Class B roof","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]},"us-wy-teton":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-teton-county","title":"Unincorporated Teton County 2024 IWUIC application","placeId":"us-wy-teton","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-01-07","effectiveOn":"2025-02-01","map":{"status":"linked-official-tool","summary":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","url":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 Class A roof: Assembly role = roof assembly; Fire rating = class a; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC Class 3 Class B roof: Assembly role = roof assembly; Fire rating is one of class a, class b; Test standard is one of astm e108, ul 790.","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/"},{"kind":"check","text":"Still undocumented for IWUIC roof-profile eave closure: Assembly role = roof profile closure.","href":"/requirements/iwuic-2024-roof-profile-closure/"},{"kind":"check","text":"Still undocumented for IWUIC valley flashing: Assembly role = valley flashing; Sheet gauge ≤ 26; Corrosion resistant = Yes; Material is one of galvanized steel.","href":"/requirements/iwuic-2024-roof-valley-flashing/"},{"kind":"application","text":"Unincorporated Teton County 2024 IWUIC application: Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This Class A roof path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Local scope: This Class B roof path applies only when Fire/EMS assigns IR3 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Local scope: This roof-profile closure applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Local scope: This valley-flashing path applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","href":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","shortName":"IWUIC Class 1–2 Class A roof","href":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-class-3-class-b-roof-assembly","shortName":"IWUIC Class 3 Class B roof","href":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-assembly","state":"undocumented"},{"attribute":"fireRating","op":"in","value":["class-a","class-b"],"state":"undocumented"},{"attribute":"testStandard","op":"in","value":["astm-e108","ul-790"],"state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-profile-closure","shortName":"IWUIC roof-profile eave closure","href":"/requirements/iwuic-2024-roof-profile-closure/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"roof-profile-closure","state":"undocumented"}]},{"requirementId":"iwuic-2024-roof-valley-flashing","shortName":"IWUIC valley flashing","href":"/requirements/iwuic-2024-roof-valley-flashing/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"valley-flashing","state":"undocumented"},{"attribute":"sheetGauge","op":"lte","value":26,"unit":"sheet-gauge","state":"undocumented"},{"attribute":"corrosionResistant","op":"eq","value":true,"state":"undocumented"},{"attribute":"material","op":"in","value":["galvanized-steel"],"state":"undocumented"}]}]}}}