Roofing Program and model No adopted WUI code we can source here. IBHS Wildfire Prepared asks for the inspection measures, and the 2024 IWUIC model says the same floor.
National floor. A ZIP opens the same question at a place where a sourced instrument exists.
Find what applies near you
Enter a ZIP before browsing the complete evidence. Matching, inherited, and place-neutral records will move first; other places and unmapped application rows will fold into expandable groups. Nothing is removed. All 3 state rule sections remain available.
Evidence prioritized for
Matching, inherited, and national evidence is open. Other locations and records not yet joined to a place are collapsed below and remain available.
The rule Model code “a roof assembly that complies with a Class A rating when tested in accordance with ASTM E 108 or UL 790”
2018 IWUIC Class 1 Class A roof. The unamended 2018 IWUIC specifies a Class A tested roof assembly for Class 1 ignition-resistant construction.
Tick for my house Products matching the model-code floor Model code Product matches below are limited to roofing and trace to the named requirement.
Additional products matching the voluntary program Voluntary program Product matches below are limited to roofing and trace to the named requirement.
Where this answer differs 14 sourced rows
14 sourced rows Model code 2018 IWUIC Class 1 Class A roof
— The unamended 2018 IWUIC specifies a Class A tested roof assembly for Class 1 ignition-resistant construction. Model code 2018 IWUIC Class 2 Class B roof
— The unamended 2018 IWUIC specifies a Class B-or-better tested roof assembly for Class 2 ignition-resistant construction. Model code 2018 IWUIC Class 3 Class C roof
— The unamended 2018 IWUIC specifies a Class C-or-better tested roof assembly for Class 3 ignition-resistant construction. Model code 2018 IWUIC roof-profile eave closure
— The unamended 2018 IWUIC requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path. Model code 2018 IWUIC valley flashing
— The unamended 2018 IWUIC specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail. Model code 2021 IWUIC Class 1–2 Class A roof
— The unamended 2021 IWUIC specifies a Class A tested roof assembly for Class 1 and Class 2 ignition-resistant construction. Model code 2021 IWUIC Class 3 Class B roof
— The unamended 2021 IWUIC specifies a Class B-or-better tested roof assembly for Class 3 ignition-resistant construction. Model code 2021 IWUIC roof-profile eave closure
— The unamended 2021 IWUIC requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path. Model code 2021 IWUIC valley flashing
— The unamended 2021 IWUIC specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail. Model code IWUIC Class 1–2 Class A roof
— The unamended 2024 IWUIC model code specifies a Class A tested roof assembly for Class 1 and Class 2 ignition-resistant construction. Model code IWUIC Class 3 Class B roof
— The unamended 2024 IWUIC model code specifies a Class B-or-better tested roof assembly for Class 3 ignition-resistant construction. Model code IWUIC roof-profile eave closure
— The unamended 2024 IWUIC model code requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path. Model code IWUIC valley flashing
— The unamended 2024 IWUIC model code specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail. Voluntary program IBHS Base Class A roof covering
— The current IBHS Base standard specifies a Class A roof covering tested to ASTM E108 or UL 790.