California / Vents
Vents in California Statewide California requires CWUIC 2025.
The rule Adopted “WUI vents, tested in accordance with ASTM E2886”
California ASTM E2886 vent. The 2025 California Wildland-Urban Interface Code includes a path for WUI vents tested to ASTM E2886 and meeting the Section 504.10.1 ember, flame, and temperature criteria.
Tick for my house Products matching California’s adopted requirements Adopted Product matches below are limited to vents and trace to the named requirement.
No sourced photo yet Able Multi-Guard intumescent soffit vents Able Sheet Metal Matches California ASTM E2886 vent Listed 8165-2363:0002 expires 2027-06-30 A listing is not a permit — your building official decides.
Save to my house No sourced photo yet Multi-Guard Fire Resistant Gable Louver Vent (13.75" x 12") Able Sheet Metal Matches California ASTM E2886 vent Listed 8165-2363:0001 expires 2027-06-30 Save to my house No sourced photo yet CF 75-V-425/17 (4.25"x17"), 75-V-425/8 (4.25"x96"), 75-V-425/10 (4.25"x120") Brand X Metals Inc. Matches California ASTM E2886 vent Listed 8165-2394:0001 expires 2027-06-30 Save to my house No sourced photo yet FP2011 Fire Plug Vent BrandGuard Vents Matches California ASTM E2886 vent Listed 8165-2232:0501 expires 2027-06-30 Save to my house No sourced photo yet UE2011 (22"x3.5"), UE2021 (14"x3.5"), UE2031 (14"x5"), UE2041 (22"x3") Brandguard Vents Matches California ASTM E2886 vent Listed 8165-2232:0502 expires 2027-06-30 Save to my house No sourced photo yet UE3011 (22”x3.5”), UE3021 (14”x3.5”), UE3031 (14”x5”), UE3041 (22”x3”) Brandguard Vents Matches California ASTM E2886 vent Listed 8165-2232:0500 expires 2027-06-30 Save to my house No sourced photo yet Wildfire Defense Vent Screen — WDM 98 OSFM BML configuration Bushfire Mitigation Solutions (Wildfire Defense Mesh) Matches California ASTM E2886 vent Listed 8165-2397:0001 expires 2027-06-30 Save to my house No sourced photo yet EOSF1220N9-1S (12"x2"), EOSF1350N32-1S (13.5"x5"), EOSF1355N35-1S (13.5"x5.5") Embers Out LLC Matches California ASTM E2886 vent Listed 8165-2214:0500 expires 2027-06-30 Save to my house No sourced photo yet FireStorm® V2™ listed vent families New Cal Metals, Inc. dba FireStorm Building Products Matches California ASTM E2886 vent Listed 8165-2426:0001 expires 2027-06-30 Save to my house No sourced photo yet F&IV01000 (4"x19"), F&IV02000 (5"x19"), F&IV03000 (6"x19"), F&IV04000 (7"x19"), F&IV05000 O'Hagin Matches California ASTM E2886 vent Listed 8165-2353:0001 expires 2027-06-30 Save to my house No sourced photo yet VG148 (8"x14"), VG1412 (14"x12"), VG1418 (14"x18"), and VG1424 (14"x24") Gable Vent Vulcan Vents Matches California ASTM E2886 vent Listed 8165-2192:0503 expires 2027-06-30 Save to my house No sourced photo yet VER2, VER2M, VER3, VER3M, VER4, VER4M, and VER6M Vulcan Eave Round Vents Vulcan Vents Matches California ASTM E2886 vent Listed 8165-2192:0500 expires 2027-06-30 Save to my house No sourced photo yet VFS414 (3.5"x14"), VFS614 (5.5"x14"), VFS814 (7.5"x14"), VFS422 (3.5"x22") Vulcan Vents Matches California ASTM E2886 vent Listed 8165-2192:0502 expires 2027-06-30 Save to my house No sourced photo yet VSC75120 (0.75"x120"), VSC15120 (1.5"x120"), VSC1120 (1"x120"), VSC2120 (2"x120") Vulcan Vents Matches California ASTM E2886 vent Listed 8165-2192:0501 expires 2027-06-30 Save to my house Additional products matching sourced guidance Guidance Product matches below are limited to vents and trace to the named requirement.
Additional products matching the model-code floor Model code Product matches below are limited to vents and trace to the named requirement.
No sourced vents product in this directory yet matches the model-code floor.
Additional products matching the voluntary program Voluntary program Product matches below are limited to vents and trace to the named requirement.
Every sourced row for this part of the house
Every sourced row for this part of the house Adopted California ASTM E2886 vent
— The 2025 California Wildland-Urban Interface Code includes a path for WUI vents tested to ASTM E2886 and meeting the Section 504.10.1 ember, flame, and temperature criteria. Tick for my house Guidance CAL FIRE vent mesh
— CAL FIRE guidance specifies a one-sixteenth- to one-eighth-inch band for noncombustible, corrosion-resistant metal mesh over vents. Tick for my house Model code 2018 IWUIC Class 1–2 vent mesh
— The unamended 2018 IWUIC specifies noncombustible corrosion-resistant mesh with openings no larger than one-quarter inch for Class 1 and Class 2 vents. Tick for my house Model code 2021 IWUIC Class 1–2 vent mesh
— The unamended 2021 IWUIC specifies noncombustible corrosion-resistant mesh with openings no larger than one-quarter inch for Class 1 and Class 2 vents. Tick for my house Model code IWUIC vent mesh
— The unamended 2024 IWUIC model code specifies noncombustible corrosion-resistant vent mesh with openings no larger than one-eighth inch as a prescriptive path. Tick for my house Voluntary program IBHS Base forced-air vent closure
— The current IBHS Base standard calls for a functional louver or flap on forced-air vents such as dryer and central-vacuum exhausts. Tick for my house Voluntary program IBHS Base vent mesh
— The 2025 IBHS Base standard permits a prescriptive vent-covering path using documented noncombustible, corrosion-resistant mesh with openings no larger than one-eighth inch. Tick for my house Voluntary program IBHS Plus metal forced-air vent closure
— The current IBHS Plus standard adds noncombustible construction to the Base functional-closure requirement for forced-air vents. Tick for my house