United States / Build / VG148 (8"x14"), VG1412 (14"x12"), VG1418 (14"x18"), and VG1424 (14"x24") Gable Vent
VG148 (8"x14"), VG1412 (14"x12"), VG1418 (14"x18"), and VG1424 (14"x24") Gable Vent This is a listed vent assembly. Listing 8165-2192:0503. This site cites ASTM E2886. Match the model and orientation.
Listed · multiple independent channels. Active CAL FIRE BML listing 8165-2192:0503, expires 2027-06-30 (verified against the live BML 2026-08-25). Multiple independent channels agree; each is shown below. This status is computed from the cited evidence by the published rule, never hand-assigned.
▲ CAL FIRE BML 8165-2192:0503 · active ▲ documented attributes match 1 requirement
Vulcan documents these gable vents as G90 hot-dipped galvanized-steel assemblies with stainless-steel ember mesh and a heat-activated intumescent closure. CAL FIRE OSFM listing 8165-2192:0503 covers the four VG base models under ASTM E2886.
Kind: listed-assembly.
Brand: Vulcan Vents . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-23. JSON (CC BY 4.0)
Can you use it here?
Enter your ZIP to see which local requirement this meets.
Documented attributes Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Published requirement matches These links are generated from the cited attributes above. They do not decide installation or a project result.
Models named on the listing Model Application VG148 (8"x14") VG1412 (14"x12") VG1418 (14"x18") VG1424 (14"x24")
Specification notes Listing is not a substitute for the adopted code or the building official. Deschutes County states it will accept products from the OSFM WUI handbook when they are shown on the drawings. Can I use this here How this product meets each requirement (8)
Requirement constraints (8)
Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
ORSC R327 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening 0.0625 in–0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
IWUIC vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
Colorado CWRC vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2018 IWUIC Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2021 IWUIC Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 3 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
VG148 (8"x14"), VG1412 (14"x12"), VG1418 (14"x18"), and VG1424 (14"x24") Gable Vent. FireApproved. https://fireapproved.com/materials/vulcan-gable-vent/. Last verified 2026-08-23. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.