Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
ORSC R327 vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh, soffit vent | retrofit mesh | matched |
| Mesh opening | Mesh opening 0.0625 in–0.125 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
IWUIC vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh, soffit vent | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.125 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
Colorado CWRC vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh, soffit vent | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.125 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
2018 IWUIC Class 1–2 vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.25 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
2021 IWUIC Class 1–2 vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.25 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
2006 Utah UWUI Class 1–2 vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.25 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |
2006 Utah UWUI Class 3 vent mesh undocumented | Field | Required | Documented value | State |
| Assembly role | Assembly role is one of foundation vent, retrofit mesh, soffit vent | retrofit mesh | matched |
| Mesh opening | Mesh opening ≤ 0.25 in | 0.0657 in | matched |
| Corrosion resistant | Corrosion resistant = Yes | Yes | matched |
| Noncombustible | Noncombustible = Yes | Not documented | undocumented |