Home / Requirements / 2021 IWUIC Class 1–2 vent mesh

2021 IWUIC Class 1 and 2 quarter-inch vent-mesh path

The unamended 2021 IWUIC specifies noncombustible corrosion-resistant mesh with openings no larger than one-quarter inch for Class 1 and Class 2 vents.

This record covers documented mesh size, material, and vent role only. The 144-square-inch opening limit, free area, installation, prohibited soffit and eave locations, alternative approval, official map, assigned class, project scope, and local amendments remain checks.

code · Jurisdictions adopting unamended 2021 IWUIC Sections 504.10 and 505.10 · Last verified 2026-08-27 · JSON (CC BY 4.0)

Published requirement text

“noncombustible corrosion-resistant mesh with openings not to exceed 1/4 inch (6.4 mm)”

2021 International Wildland-Urban Interface Code, Sections 504.10 and 505.10 — International Code Council

Where this instrument is documented

Instrument iwuic-2021.

Set a location to read how this instrument lands where you are.

PlaceForceReachDatedChecks openSource
Pennsylvania active application documented statewide effective 2026-01-01 4 34 Pa. Code § 403.21 Uniform Construction Code

Each place page carries that place's boundary, project scope and open official checks in full; this page's JSON twin carries them per application.

Machine-readable constraints

AttributeOperatorValueUnit
assemblyRole in foundation-vent–retrofit-mesh
meshSizeInch lte 0.25 inch
corrosionResistant eq true
noncombustible eq true

Products with documented matching attributes

Open the Build rules that quote this requirement

Sources

2021 IWUIC Class 1 and 2 quarter-inch vent-mesh path. FireApproved. https://fireapproved.com/requirements/iwuic-2021-class-1-2-quarter-inch-vent-mesh/. Last verified 2026-08-27.