United States / Build / EOSF1220N9-1S (12"x2"), EOSF1350N32-1S (13.5"x5"), EOSF1355N35-1S (13.5"x5.5")
EOSF1220N9-1S (12"x2"), EOSF1350N32-1S (13.5"x5"), EOSF1355N35-1S (13.5"x5.5") This is a listed vent assembly. Listing 8165-2214:0500. This site cites ASTM E2886. Match the model and orientation.
Listed. Derived from the cited listings by a published rule, never hand-assigned.
▲ CAL FIRE BML 8165-2214:0500 · active
Kind: listed-assembly.
Brand: Embers Out LLC . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-23. JSON (CC BY 4.0)
Can you use it here?
Enter your ZIP to see which local requirement this meets.
The September 2025 handbook's Embers Out description lists EOSF1220N9-1S at 12 by 2 inches, EOSF1350N32-1S at 13.5 by 5 inches and EOSF1355N35-1S at 13.5 by 5.5 inches in its Elite Soffit/Foundation group. Its separate EORV Retro-Fit group includes EORV1350N31-1S at 13 by 4.75 inches. Use the stated dimensions with the exact model designation; the digits in a model code are not a substitute for its listed size.
The vents use 22-gauge galvanized 1018 cold-rolled steel with 1/8-inch square openings on the exterior surface. Inside the vent body are two layers of Textech Belcotex silica-fiber mat. OSFM gives the density as 12.6/15.4 ounces per square yard without explaining the slash. That notation does not identify a separate value for each layer.
These are perforated-steel vents with internal mats, rather than a specification for woven replacement screen. ASTM E2886 is the cited test protocol for the assembled product. For a soffit, foundation or retrofit selection, identify the listed model and follow the manufacturer's installation instructions and product data sheets referenced by OSFM. Confirm the exact GOVmotus entry with the complete vent construction retained.
On this page
Documented attributes Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Published requirement matches These links are generated from the cited attributes above. They do not decide installation or a project result.
Models named on the listing Model Application EOSF1220N9-1S (12"x2") EOSF1350N32-1S (13.5"x5") EOSF1355N35-1S (13.5"x5.5") EOSF1435N20-1S (14"x3.5") EOSF1440N25-1S (14"x4") EOSF1450N32-1S (14"x5") EOSF1460N40-1S (14"x6") EOSF1480N55-1S (14"x8") EOSF1550N36-1S (15"x5") EOSF1560N44-1S (15"x6") EOSF1590N64-1S (15"x9") EOSF2230N28-1S (22"x3") EOSF2235N37-1S (22"x3.5") EOSF2255N57-1S (22"x5.5") EOSF2275N84-1S (22"x7.5") EOSF4820N40-1S (48"x2") EORV1350N31-1S (13"x4.75") EORV1435N20-1S (13.75"x3.25") EORV1450N32-1S (13.75"x4.75") EORV1460N40-1S (13.75"x5.75") EORV1480N55-1S (13.75"x7.75") EORV1550N35-1S (14.75"x4.75") EORV1560N43-1S (14.75"x5.75") EORV2255N57-1S (21.75"x5.25") EORV2290N101-1S (21.75"x8.75")
Specification notes Listing is from the OSFM WUI handbook. Confirm the live GOVmotus record and the exact model before specification. Can I use this here How this product meets each requirement (8)
Requirement constraints (8)
Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
ORSC R327 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening 0.0625 in–0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
IWUIC vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
Colorado CWRC vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.125 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2018 IWUIC Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2021 IWUIC Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 3 vent mesh undocumented Field Required Documented value State Assembly role Assembly role is one of foundation vent, retrofit mesh, soffit vent Not documented undocumented Mesh opening Mesh opening ≤ 0.25 in Not documented undocumented Corrosion resistant Corrosion resistant = Yes Not documented undocumented Noncombustible Noncombustible = Yes Not documented undocumented
EOSF1220N9-1S (12"x2"), EOSF1350N32-1S (13.5"x5"), EOSF1355N35-1S (13.5"x5.5"). FireApproved. https://fireapproved.com/materials/embers-out-llc-eosf1220n9-1s-eosf1350n32-1s-eosf1355n35-1s/. Last verified 2026-08-23. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.