Taylorsville, Utah / Roofing

Roofing in Taylorsville

Local adoption Taylorsville adopted 2006 Utah UWUI. This is the rule.

For Taylorsville roofing, the requirement for Taylorsville roofing is 2006 Utah UWUI Class 1 Class A roof. On Taylorsville roofing, it is shown as adopted. Read the Taylorsville roofing rule, then compare 23 matched Taylorsville roofing products.

Before Taylorsville roofing work begins, review Taylorsville roofing project checks. Those Taylorsville roofing checks flag scope still to confirm. The Taylorsville roofing links keep the rule and product list together.

The rule

Adopted “Roofs shall have a Class A roof covering or a Class A roof assembly.”

2006 Utah UWUI Class 1 Class A roof. The 2006 Utah UWUI names a Class A roof assembly as one Class 1 ignition-resistant construction path.

Products matching Taylorsville’s adopted requirements

Adopted Product matches below are limited to roofing and trace to the named requirement.

Additional products matching the model-code floor

Model code Product matches below are limited to roofing and trace to the named requirement.

Additional products matching the voluntary program

Voluntary program Product matches below are limited to roofing and trace to the named requirement.

No sourced roofing product in this directory yet matches the voluntary program.

Open checks for this answer

These checks stay open because the sourced instrument leaves them to the official record, not because this page skipped them:

  • The official boundary that would put a parcel inside the application.
  • Confirmation from the building official for this project.
  • The official hazard class for the lot.
  • The official hazard or WUI map for the lot.
  • Whether this project type is in scope of the instrument.
1 requirement row has no matched product in the directory
  • roofing: utah-uwui-2006-class-2-3-noncombustible-roof-covering

Every sourced row for this part of the house

  • Adopted 2006 Utah UWUI Class 1 Class A roof — The 2006 Utah UWUI names a Class A roof assembly as one Class 1 ignition-resistant construction path.
  • Adopted 2006 Utah UWUI noncombustible roof covering — The 2006 Utah UWUI names an approved noncombustible roof covering as one Class 2 and Class 3 path.
  • Adopted 2006 Utah UWUI Class 2 Class B roof — The 2006 Utah UWUI names a Class B-or-better roof assembly as one Class 2 ignition-resistant construction path.
  • Adopted 2006 Utah UWUI Class 3 Class C roof — The 2006 Utah UWUI names a Class C-or-better roof assembly as one Class 3 ignition-resistant construction path.
  • Adopted 2006 Utah UWUI Class A roof covering — The 2006 Utah UWUI names a Class A roof covering in Class 1, Class 2, and Class 3 ignition-resistant construction.
  • Adopted 2006 Utah UWUI roof-profile eave closure — The 2006 Utah UWUI requires roof-profile spaces at eave ends to be firestopped against flame or ember entry in all three classes.
  • Model code 2018 IWUIC Class 1 Class A roof — The unamended 2018 IWUIC specifies a Class A tested roof assembly for Class 1 ignition-resistant construction.
  • Model code 2018 IWUIC Class 2 Class B roof — The unamended 2018 IWUIC specifies a Class B-or-better tested roof assembly for Class 2 ignition-resistant construction.
  • Model code 2018 IWUIC Class 3 Class C roof — The unamended 2018 IWUIC specifies a Class C-or-better tested roof assembly for Class 3 ignition-resistant construction.
  • Model code 2018 IWUIC roof-profile eave closure — The unamended 2018 IWUIC requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path.
  • Model code 2018 IWUIC valley flashing — The unamended 2018 IWUIC specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail.
  • Model code 2021 IWUIC Class 1–2 Class A roof — The unamended 2021 IWUIC specifies a Class A tested roof assembly for Class 1 and Class 2 ignition-resistant construction.
  • Model code 2021 IWUIC Class 3 Class B roof — The unamended 2021 IWUIC specifies a Class B-or-better tested roof assembly for Class 3 ignition-resistant construction.
  • Model code 2021 IWUIC roof-profile eave closure — The unamended 2021 IWUIC requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path.
  • Model code 2021 IWUIC valley flashing — The unamended 2021 IWUIC specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail.
  • Model code IWUIC Class 1–2 Class A roof — The unamended 2024 IWUIC model code specifies a Class A tested roof assembly for Class 1 and Class 2 ignition-resistant construction.
  • Model code IWUIC Class 3 Class B roof — The unamended 2024 IWUIC model code specifies a Class B-or-better tested roof assembly for Class 3 ignition-resistant construction.
  • Model code IWUIC roof-profile eave closure — The unamended 2024 IWUIC model code requires profile spaces at roof eave ends to block flame and ember entry or use the named cap-sheet path.
  • Model code IWUIC valley flashing — The unamended 2024 IWUIC model code specifies No. 26 galvanized corrosion-resistant metal valley flashing over a named full-width cap-sheet detail.
  • Voluntary program IBHS Base Class A roof covering — The current IBHS Base standard specifies a Class A roof covering tested to ASTM E108 or UL 790.