Glossary / Class A

Class A fire rating

The most severe roof-assembly class under ASTM E108 or UL 790. Oregon R327’s floor is Class B. IBHS Essential asks for Class A.

Class A is the highest of three classes, A, B and C, that ASTM E108 and UL 790 assign to a roof covering tested as installed on a deck, with the underlayment the test used. The methods are titled fire tests of roof coverings; the class attaches to that covering-on-the-tested-deck, never to shingles in a bag. Change the deck or skip the named underlayment and the class does not follow.

Who requires it. California's CWUIC 504.2 requires a Class A fire classification tested to ASTM E108 or UL 790 in mapped fire hazard areas (requirement). The 2024 IWUIC model code specifies a Class A tested roof assembly for Class 1 and 2 construction (requirement). Colorado's 2025 CWRC specifies a Class A covering or assembly (requirement). IBHS Wildfire Prepared Home specifies a Class A roof covering (requirement). Oregon R327, where adopted, is the one people trip on: its floor is a Class B-rated assembly equivalent, with wood shakes and shingles not permitted. Class A is not an Oregon mandate.

Reading a listing. California's OSFM handbook category 8180 lists non-wood roof covering assemblies by ID, each naming the covering, deck and underlayment tested; how to read a Class A roof listing walks one row. Metal roofs are not automatically Class A: two Metal Sales Image II rows on this site name different decks for the same covering family. IBHS also treats a debris-covered Class A roof as failing its checklist; the class is a test result, and the roof still has to be kept clear. The roofing hub holds the listed products and the places where the rule differs.

Questions

What fire rating is Class A?

The most severe exposure class under ASTM E108 and UL 790: the covering on its tested deck resisted the intermittent-flame, spread-of-flame and burning-brand tests at the Class A level. B and C are the lower exposures.

Is Class A fire rating 1 hour?

No. A one-hour rating comes from ASTM E119 or UL 263, interior fire-resistance tests of walls and floors. Class A is a roof-covering exposure test with no hour figure attached.

What is better, Class A or Class C fire rating?

Class A is the more severe exposure and the higher protection; C is the least. Kittitas County, for one, requires no less than Class A in high and extreme hazard areas and Class C in low and general ones.

What shingles are Class A?

None by themselves. The class belongs to the covering installed on the deck and underlayment tested, so an asphalt, tile or metal covering can be Class A in one listed system and not in another. The OSFM 8180 listing, or the manufacturer's E108 or UL 790 report for the whole system, is the answer.

Last verified 2026-08-23. JSON (CC BY 4.0)