QAI Class A is a covering result on a complete assembly that uses Class B treated FSR shakes or shingles with a specified noncombustible covering or ASTM D3909 cap sheet. ASTM E108 is the test standard on attributes.
This record has 2 listings: OSFM 4150-1735:0100 and ICC-ES ESR-1410 (ESR-1410). Warnings spell the Class A / Class B / cap-sheet trap. A shake standing alone is not that QAI covering result.
Lot comparison is where those two listing rows meet a place. Class A here is the QAI stack with the ASTM D3909 cap sheet or the specified noncombustible covering, not a treatment label on the cedar.
Documented attributes
Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Class A applies only to the complete QAI assembly using Class B treated FSR shakes or shingles with the specified noncombustible covering or ASTM D3909 cap sheet. Match the treatment class, deck, underlayment, starter course, fasteners, and every installation condition.
QAI CERus-1032 requires removal of existing roof coverings for reroofing and limits treated cedar species, sheathing, underlayment, and fasteners as stated in the report.
FSR pressure-treated western red cedar shakes and shingles. FireApproved. https://fireapproved.com/materials/fsr-treatment-inc-model-fsr-pressure-treated-no-1-grade-western-red/. Last verified 2026-08-25.