United States / Build / Shakertown (8140-2032:0003)

Shakertown (8140-2032:0003): type figure and course assembly, drawn from this record's sourced dimensions. No dimension is drawn that its source did not publish.
Shakertown (8140-2032:0003) — type figure and course assembly. Drawn from this record's own sourced values; every dimension on it is one a published document states, and a parameter the source did not publish is named on the drawing rather than estimated. The profile is traced from the manufacturer's own dimensioned drawing, reviewed and signed. CC BY 4.0.

Shakertown (8140-2032:0003)

This is a listed siding assembly. Listing 8140-2032:0003. This site cites SFM 12-7A-1. Match the model and orientation.

Shakertown® Dolly Varden Tongue & Grooved, Exterior Cedar Wall Siding, 4" and 6" nominal width, 8’, 10', 12' lengths, 1” nominal thickness (11/16" true thickness) exposure siding product, Western Red Cedar and fir bonded into 7 ply panel. For horizontal or *vertical installation only. Refer to the manufacturer's installation instructions and product data sheets.

Kind: listed-assembly. Brand: Shakertown. Listing evidence: OSFM WUI handbook 2026-08-25. Page reviewed 2026-08-23. JSON (CC BY 4.0)

View Saved

Can you use it here?

Enter your ZIP to see which local requirement this meets.

Documents for this product

Each link opens the publisher's own copy, so you read the revision they are shipping today.

Spec sheets

  • Dolly Varden® Reinforced T&G Paneling flyer, 2026 — Shakertown Corporation · dated 2026-07-01 · PDF
    Page 2 carries a dimensioned section (5-1/4" / 3-1/4" face top and bottom, 11/16" thickness, 1/8" reveal) beside a specification block that publishes the face widths, the actual thickness and both profile names. The face widths are the rhythm dimension and there are two of them.

Documented attributes

Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.

AttributeValueEvidence source
Fire
Test standard sfm 12 7a 1 OSFM Building Materials Listing — 8140-2032:0003 (official-listing · Listing 8140-2032:0003, TEST PROTOCOL)TEST PROTOCOL: SFM 12-7A-1

Published requirement matches

These links are generated from the cited attributes above. They do not decide installation or a project result.

ProgramID / sourceEvidence dateExpiresStatus
CAL FIRE BML 8140-2032:0003 · Search BML for 8140-2032:0003 2026-08-25 2027-06-30 listed

Tests and programs cited

Specification notes

Sources

Shakertown (8140-2032:0003). FireApproved. https://fireapproved.com/materials/shakertown-8140-2032-0003/. Last verified 2026-08-23.