Home / Materials / Hardie® Soffit non-vented fiber-cement panels
Hardie® Soffit non-vented fiber-cement panels This is a listed eaves assembly. Listing 8160-2026:0007. This site cites cal-fire-bml. Match the model and orientation. A listing is not a permit.
Listed · multiple independent channels. Active CAL FIRE BML listing 8160-2026:0007, expires 2027-06-30 (verified against the live BML 2026-08-25). Multiple independent channels agree; each is shown below.
▲ CAL FIRE BML 8160-2026:0007 · active ▲ ICC-ES ESR-2273 · active ▲ documented attributes match 8 requirements
Status derived from the cited listings by a published rule, never hand-assigned. Each chip
above is one evidence channel and its direction. A listing is not a permit — the authority
having jurisdiction decides.
James Hardie documents non-vented Smooth and Cedarmill fiber-cement soffit panels and states that Hardie Soffit panels are noncombustible. CAL FIRE OSFM listing 8160-2026:0007 covers non-vented HardieSoffit under-eave material in 3/16-inch and 1/4-inch thicknesses.
Kind: listed-assembly.
Brand: James Hardie Building Products, Inc. . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-25. JSON (CC BY 4.0)
Documented attributes Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Published requirement matches These links are generated from the cited attributes above. They do not decide installation or a project result.
Program ID / source Evidence date Expires Status CAL FIRE BML 8160-2026:0007 · Search BML for 8160-2026:0007 2026-08-25 2027-06-30 listed ICC-ES ESR-2273 · Record 2026-08-24 listed
Models named on the listing Model Application Hardie Soffit Non-Vented Smooth enclosed eave or soffit Hardie Soffit Non-Vented Cedarmill enclosed eave or soffit
Match the non-vented profile, panel thickness, texture, fasteners, framing, joints, and installation details to OSFM listing 8160-2026:0007 and the manufacturer instructions. OSFM listing is not a permit. The authority having jurisdiction decides. Can I use this here
This trace joins product evidence to a sourced code application, then keeps every boundary,
map, date, project check, documented constraint match, and still-undocumented field visible.
It is not a permit result.
Full explorer: Can I use this here .
Set a location for the local trace Without a place, no local application is inferred. The collapsed jurisdiction index below keeps every sourced static trace available.
Set a ZIP to read the local force for this product. Every static jurisdiction trace stays below.
In this place , this meets the model code 2018 IWUIC Class 1 noncombustible eave rule.
In this place , this meets the adopted IWUIC Class 1 noncombustible eave rule.
In this place , this meets the adopted California noncombustible eave rule.
In this place , this meets the available for local adoption Colorado CWRC noncombustible eave rule.
In this place , this meets the adopted 2018 IWUIC Class 1 noncombustible eave rule.
In this place , this meets the available for local adoption ORSC R327 noncombustible underside rule.
In this place , this meets the adopted ORSC R327 noncombustible underside rule.
In this place , this meets the adopted 2021 IWUIC Class 1 noncombustible eave rule.
In this place , this meets the adopted Austin Zone A noncombustible eave rule.
The rule and every matching product for the United States
Save to my house How this product meets each requirement (16)
Requirement constraints (16)
Each table below compares this product's documented attributes against one published
requirement. That comparison is a fact about the product and the requirement, and does not
change from place to place, so it is printed once.
Requirement constraints (16)
Each table compares this product's documented attributes with one published
requirement. That comparison does not change from place to place, so it is printed
once here and linked from every jurisdiction below.
Austin Zones B–C solid eave enclosure undocumented Field Required Documented value State Solid surface Solid surface = Yes Yes matched Thickness Thickness ≥ 0.75 in Not documented undocumented
IWUIC Class 2 solid eave enclosure undocumented Field Required Documented value State Solid surface Solid surface = Yes Yes matched Thickness Thickness ≥ 0.75 in Not documented undocumented
Where this applies
A product is a national record; where it applies is a fact about a place. The rule that
binds a given address — and every product matching it — is published on that place's own
answer page, linked above and re-linked by the location lens. The complete per-place
claim graph for this record, including every open official check, is in its
JSON twin .
Hardie® Soffit non-vented fiber-cement panels. FireApproved. https://fireapproved.com/materials/james-hardie-building-products-inc-hardiesoffit-un-vented-fiber-cement/. Last verified 2026-08-25. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.