United States / Build / Canyon Lumber Company (8160-2380:0003)

Canyon Lumber Company (8160-2380:0003): eave assembly section, drawn from this record's sourced dimensions. No dimension is drawn that its source did not publish.
Canyon Lumber Company (8160-2380:0003) — eave assembly section. Drawn from this record's own sourced values; every dimension on it is one a published document states, and a parameter the source did not publish is named on the drawing rather than estimated. CC BY 4.0.

Canyon Lumber Company (8160-2380:0003)

This is a listed eave assembly. Listing 8160-2380:0003. This site cites SFM 12-7A-3. Match the model and orientation.

Kind: listed-assembly. Brand: Canyon Lumber Company. Listing evidence: OSFM WUI handbook 2026-08-25. Page reviewed 2026-08-23. JSON (CC BY 4.0)

View Saved

Can you use it here?

Enter your ZIP to see which local requirement this meets.

Canyon Lumber Company listing 8160-2380:0003 is listed by CAL FIRE for wildfire-area use.

The official listing covers a specific assembly: nominal 1-inch-by-6-inch Micro V Western Red Cedar siding panels installed directly on nominal 2-inch-by-4-inch SPF studs spaced 16 inches on center. It appears in OSFM category 8160 for eaves and identifies SFM 12-7A-3 as the test protocol.

The product appeared in the September 2025 OSFM WUI Listed Products Handbook. CAL FIRE's live record was checked on August 25, 2026; it listed June 30, 2027 as the expiration date. That status applies to the exact model and assembly described, not to Canyon Lumber Company products or cedar siding generally. Before specifying it, confirm the live CAL FIRE record, match listing number 8160-2380:0003, and follow the manufacturer’s installation instructions and product data sheets.

Documents for this product

Each link opens the publisher's own copy, so you read the revision they are shipping today.

CAD drawings

  • 1x6 Engineered CAD drawings — The Micro V and The Fine Line, dimensioned end sections with a product data block — Canyon Lumber Company · dated 2024-01-11 · PDF
    Two pages, NO TEXT LAYER AT ALL — rendered at 150 dpi and read as images. PAGE 1 IS THIS RECORD'S PRODUCT: it is titled 1x6 THE MICRO V and this listing is the Micro V one of Canyon's two, which is what lets the drawing bind here rather than to 8160-2380:0002. Page 2, THE FINE LINE, is a different pattern — a 1/8" square-shouldered gap in place of the 1/16" micro-V — and is not this record's. The census scored this record a MISS because its listing states only a nominal size; the manufacturer's drawing is what recovers it.

Documented attributes

Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.

AttributeValueEvidence source
Fire
Test standard sfm 12 7a 3 OSFM Building Materials Listing — 8160-2380:0003 (official-listing · Listing 8160-2380:0003, TEST PROTOCOL)TEST PROTOCOL: SFM 12-7A-3

Published requirement matches

These links are generated from the cited attributes above. They do not decide installation or a project result.

ProgramID / sourceEvidence dateExpiresStatus
CAL FIRE BML 8160-2380:0003 · Search BML for 8160-2380:0003 2026-08-25 2027-06-30 listed

Tests and programs cited

Specification notes

Sources

Canyon Lumber Company (8160-2380:0003). FireApproved. https://fireapproved.com/materials/canyon-lumber-company-8160-2380-0003/. Last verified 2026-08-23.