Arclin Firepoint 2500 exterior wall sheathing assembly

This is a listed siding assembly. Listing 1080-2422:0001. This site cites astm-e84. Match the model and orientation. A listing is not a permit.

CAL FIRE OSFM listing 1080-2422:0001 covers a one-hour exterior-wall assembly using 15/32-inch Douglas-fir CDX plywood with Firepoint 2500 laminated to the exterior face, 2×4 Douglas-fir studs at 16 inches on center, R13 kraft-faced fiberglass insulation, and 5/8-inch Type X gypsum on the interior. Arclin documents Firepoint 2500 exterior-wall use and ASTM E84 performance.

Kind: listed-assembly. Brand: Arclin Surfaces. Listing evidence: OSFM WUI handbook 2026-08-25. Page reviewed 2026-08-25. JSON (CC BY 4.0)

Documented attributes

Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.

AttributeValueEvidence source
Material wood Firepoint wall assembly brochure (manufacturer)
Fire resistance 60 min Firepoint wall assembly brochure (manufacturer)

Published requirement matches

These links are generated from the cited attributes above. They do not decide installation or a project result.

ProgramID / sourceEvidence dateExpiresStatus
CAL FIRE BML 1080-2422:0001 · Search BML for 1080-2422:0001 2026-08-25 2027-06-30 listed

Tests and programs cited

Models named on the listing

ModelApplication
Firepoint 2500 15/32-inch exterior sheathing in the listed one-hour wall assembly