Fire-resistant windows

Program and model No adopted WUI code we can source here. IBHS Wildfire Prepared asks for the inspection measures, and the 2024 IWUIC model says the same floor.

National floor. A ZIP opens the same question at a place where a sourced instrument exists.

The answer

Fire-resistant windows in the wildfire codes are about the glass. Where Oregon R327 is adopted, R327.3.6 allows tempered glass, multilayered glazed panels, glass block or 20-minute rated glazing, so dual-pane energy-code windows qualify. California CWUIC wants multilayered panels with at least one tempered pane, glass block, a 20-minute rating, or a product tested to SFM 12-7A-2 (OSFM category 8120). IBHS Wildfire Prepared Enhanced specifies dual-pane with both panes tempered, 20-minute glass or glass block. Dual-pane is not the same as tempered.

What the sourced rules ask for

For national windows, the national windows requirement is 2018 IWUIC Class 1–2 multilayered glazing. On national windows, it is shown as model code. Read the national windows rule, then compare 26 matched national windows products.

Review 18 national windows place answers before choosing among national windows records. The national windows links keep the rule, products, and place differences together.

Find what applies near you

Enter a ZIP before browsing the complete evidence. Matching, inherited, and place-neutral records will move first; other places and unmapped application rows will fold into expandable groups. Nothing is removed. All 3 state rule sections remain available.

The rule

Model code “shall be tempered glass, multilayered glazed panels, glass block or have a fire protection rating”

2018 IWUIC Class 1–2 multilayered glazing. The unamended 2018 IWUIC includes multilayered glazed panels as one exterior glazing path in Class 1 and Class 2 construction.

Products matching the model-code floor

Model code Product matches below are limited to windows and trace to the named requirement.

Additional products matching the voluntary program

Voluntary program Product matches below are limited to windows and trace to the named requirement.

No sourced windows product in this directory yet matches the voluntary program.

Questions

What is a 30-minute fire rated window?

A duration rating from the fire-window tests used for rated walls. The wildfire books on this site name 20-minute rated glazing as one path beside tempered and multilayered glass; the question they ask is about the glass, not the minutes.

Do wildfire codes require tempered glass?

California CWUIC requires at least one tempered pane unless another named path is used. Oregon R327 does not: multilayered glazing is enough where it is adopted. IBHS Enhanced asks for both panes tempered.

Do dual-pane energy-code windows satisfy Oregon R327?

Where R327 is adopted, yes as multilayered glazed panels. R327.3.6 allows tempered glass, multilayered glazed panels, glass block, or 20-minute rated glazing. Dual-pane energy-code windows are multilayered. Deschutes County names double-pane windows as a commonly used fire-hardening material. Confirm with the building official. That is not California practice.

Do they satisfy California Chapter 7A or CWUIC?

No. The live California book is CWUIC. Exterior glazing needs multilayered panels with at least one tempered pane, glass block, a 20-minute rating, or a product tested to SFM 12-7A-2 (OSFM category 8120). Dual-pane annealed energy-code glass is not that path.

Is dual-pane the same as tempered?

No. Dual-pane means two or more layers of glass. Tempered means heat-treated glass that resists breaking. You can have dual-pane annealed, dual-pane with one tempered pane, or dual-pane with both panes tempered. Oregon, California, and IBHS Enhanced are not the same combination.

Do I need an OSFM listed window in Oregon?

No. OSFM listing is voluntary for most WUI products. Where R327 is adopted, multilayered or tempered glass is a prescriptive path. Deschutes County will accept OSFM handbook products when those products are shown on the drawings. That is local practice.

Does IBHS Essential require tempered windows?

IBHS Enhanced (Plus) specifies dual-pane glass with tempered panes in both, or 20-minute glass, or glass block. Essential is the ember package (roof, vents, Zone 0). A carrier can still add a window line. Ask the carrier.

Where this answer differs

4 sourced rows