Oregon / Vents
Vents in Oregon Local option Not adopted here that we can source. Your county could adopt ORSC R327.
The rule Available for local adoption “noncombustible corrosion-resistant metal wire mesh ... minimum of 1/16-inch ... maximum of 1/8-inch”
ORSC R327 vent mesh. Oregon R327 provides a prescriptive mesh path for covered ventilation openings where a local municipality has adopted the section.
Tick for my house Products matching the published local-adoption option Available for local adoption Product matches below are limited to vents and trace to the named requirement.
Additional products matching the model-code floor Model code Product matches below are limited to vents and trace to the named requirement.
No sourced vents product in this directory yet matches the model-code floor.
Additional products matching the voluntary program Voluntary program Product matches below are limited to vents and trace to the named requirement.
Every sourced row for this part of the house
Every sourced row for this part of the house Available for local adoption ORSC R327 vent mesh
— Oregon R327 provides a prescriptive mesh path for covered ventilation openings where a local municipality has adopted the section. Tick for my house Model code 2018 IWUIC Class 1–2 vent mesh
— The unamended 2018 IWUIC specifies noncombustible corrosion-resistant mesh with openings no larger than one-quarter inch for Class 1 and Class 2 vents. Tick for my house Model code 2021 IWUIC Class 1–2 vent mesh
— The unamended 2021 IWUIC specifies noncombustible corrosion-resistant mesh with openings no larger than one-quarter inch for Class 1 and Class 2 vents. Tick for my house Model code IWUIC vent mesh
— The unamended 2024 IWUIC model code specifies noncombustible corrosion-resistant vent mesh with openings no larger than one-eighth inch as a prescriptive path. Tick for my house Voluntary program IBHS Base forced-air vent closure
— The current IBHS Base standard calls for a functional louver or flap on forced-air vents such as dryer and central-vacuum exhausts. Tick for my house Voluntary program IBHS Base vent mesh
— The 2025 IBHS Base standard permits a prescriptive vent-covering path using documented noncombustible, corrosion-resistant mesh with openings no larger than one-eighth inch. Tick for my house Voluntary program IBHS Plus metal forced-air vent closure
— The current IBHS Plus standard adds noncombustible construction to the Base functional-closure requirement for forced-air vents. Tick for my house