Salt Lake City, Utah / Siding

Siding in Salt Lake City

Local adoption Salt Lake City adopted 2006 Utah UWUI. This is the rule.

For Salt Lake City siding, the requirement for Salt Lake City siding is 2006 Utah UWUI Class 1–2 noncombustible wall. On Salt Lake City siding, it is shown as adopted. Read the Salt Lake City siding rule, then compare 12 matched Salt Lake City siding products.

Before Salt Lake City siding work begins, review Salt Lake City siding project checks. Those Salt Lake City siding checks flag scope still to confirm. The Salt Lake City siding links keep the rule and product list together.

The rule

Adopted “constructed with approved noncombustible materials”

2006 Utah UWUI Class 1–2 noncombustible wall. The 2006 Utah UWUI includes approved noncombustible material as an exterior-wall path in Class 1 and Class 2 construction.

Products matching Salt Lake City’s adopted requirements

Adopted Product matches below are limited to siding and trace to the named requirement.

Additional products matching the model-code floor

Model code Product matches below are limited to siding and trace to the named requirement.

No sourced siding product in this directory yet matches the model-code floor.

Additional products matching the voluntary program

Voluntary program Product matches below are limited to siding and trace to the named requirement.

No sourced siding product in this directory yet matches the voluntary program.

Open checks for this answer

These checks stay open because the sourced instrument leaves them to the official record, not because this page skipped them:

  • Whether the instrument is in force for this project's date.
  • The official boundary that would put a parcel inside the application.
  • Confirmation from the building official for this project.
  • The official hazard class for the lot.
  • The official hazard or WUI map for the lot.
  • Whether this project type is in scope of the instrument.
1 requirement row has no matched product in the directory
  • siding: utah-uwui-2006-table-503-nc-exterior-wall

Every sourced row for this part of the house

  • Adopted 2006 Utah UWUI Class 1–2 noncombustible wall — The 2006 Utah UWUI includes approved noncombustible material as an exterior-wall path in Class 1 and Class 2 construction.
  • Adopted 2006 Utah UWUI Class 1–2 one-hour wall — The 2006 Utah UWUI includes materials approved for at least one-hour fire-resistance-rated construction on the exterior side as a Class 1 and Class 2 exterior-wall path.
  • Adopted 2006 Utah UWUI Table 503.1 N.C. wall — When Table 503.1 returns an N.C. result, the 2006 Utah UWUI adds both a one-hour exterior-wall rating and a noncombustible exterior surface.
  • Model code 2018 IWUIC Class 1–2 noncombustible wall — The unamended 2018 IWUIC includes approved noncombustible material as an exterior-wall path in Class 1 and Class 2 construction.
  • Model code 2021 IWUIC Class 1–2 noncombustible wall — The unamended 2021 IWUIC includes approved noncombustible material as an exterior-wall path in Class 1 and Class 2 construction.
  • Model code IWUIC Class 1–2 noncombustible wall — The unamended 2024 IWUIC model code includes approved noncombustible material as an exterior-wall path in Class 1 and Class 2 construction.
  • Model code IWUIC Class 1 wall-base protection — The unamended 2024 IWUIC model code specifies a six-inch vertical metal or noncombustible wall-base detail at ground, deck, and roof intersections for Class 1 construction.
  • Voluntary program IBHS Base six-inch wall-base protection — The current IBHS Base standard specifies at least six vertical inches of noncombustible material at the base of exterior walls.