Taylorsville, Utah / Decking
Decking in Taylorsville Local adoption Taylorsville adopted 2006 Utah UWUI. This is the rule.
The rule Adopted “constructed of approved noncombustible materials”
2006 Utah UWUI Class 1–2 noncombustible deck. The 2006 Utah UWUI includes approved noncombustible materials as a Class 1 and Class 2 path for attached unenclosed accessory structures and projections such as decks.
Tick for my house Products matching Taylorsville’s adopted requirements Adopted Product matches below are limited to decking and trace to the named requirement.
Additional products matching the model-code floor Model code Product matches below are limited to decking and trace to the named requirement.
No sourced decking product in this directory yet matches the model-code floor.
Additional products matching the voluntary program Voluntary program Product matches below are limited to decking and trace to the named requirement.
Every sourced row for this part of the house
Every sourced row for this part of the house Adopted 2006 Utah UWUI Class 1–2 noncombustible deck
— The 2006 Utah UWUI includes approved noncombustible materials as a Class 1 and Class 2 path for attached unenclosed accessory structures and projections such as decks. Tick for my house Adopted 2006 Utah UWUI Class 1–2 one-hour deck
— The 2006 Utah UWUI includes one-hour fire-resistance-rated construction as a Class 1 and Class 2 path for attached unenclosed accessory structures and projections such as decks. Tick for my house Model code 2018 IWUIC Class 1–2 noncombustible deck
— The unamended 2018 IWUIC includes approved noncombustible materials as one path for attached unenclosed accessory structures and projections such as decks. Tick for my house Model code 2021 IWUIC Class 1–2 noncombustible deck
— The unamended 2021 IWUIC includes approved noncombustible materials as one path for attached unenclosed accessory structures and projections such as decks. Tick for my house Model code IWUIC Class 1–2 noncombustible deck
— The unamended 2024 IWUIC model code includes approved noncombustible materials as one path for attached unenclosed accessory structures and projections such as decks. Tick for my house Voluntary program IBHS Base under-deck mesh
— The 2025 IBHS Base standard specifies perimeter enclosure mesh for decks whose walking surface is four feet or less above ground. Tick for my house Voluntary program IBHS Plus solid deck surface
— The current IBHS Plus retrofit path specifies a solid noncombustible deck walking surface with no gaps. Tick for my house