United States / Build / Pli-Dek Standard waterproof walking-deck system
Pli-Dek Standard waterproof walking-deck system This is a listed decking assembly. Listing 8110-2327:0500. This site cites SFM 12-7A-4. Match the model and orientation.
Listed · multiple independent channels. Active CAL FIRE BML listing 8110-2327:0500, expires 2027-06-30 (verified against the live BML 2026-08-25). Multiple independent channels agree; each is shown below. This status is computed from the cited evidence by the published rule, never hand-assigned.
▲ CAL FIRE BML 8110-2327:0500 · active ▲ ICC-ES ESR-2097 · active ▲ documented attributes match 3 requirements
Pli-Dek documents its Standard System as a one-hour, Class A waterproof deck coating for plywood substrates, using galvanized metal lath and polymer-cement coats. CAL FIRE OSFM listing 8110-2327:0500 covers the Pli-Dek ESR-2097 system over minimum 5/8-inch plywood, while ICC-ES ESR-2097 evaluates the broader Pli-Dek and Con-Dek system families under report-specific conditions.
Kind: listed-assembly.
Brand: Pli-Dek Systems . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-25. JSON (CC BY 4.0)
Can you use it here?
Enter your ZIP to see which local requirement this meets.
Documents for this product Each link opens the publisher's own copy, so you read the revision they are shipping today.
Documented attributes Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Published requirement matches These links are generated from the cited attributes above. They do not decide installation or a project result.
Program ID / source Evidence date Expires Status CAL FIRE BML 8110-2327:0500 · Search BML for 8110-2327:0500 2026-08-25 2027-06-30 listed ICC-ES ESR-2097 · Record 2026-08-25 listed
Models named on the listing Model Application Pli-Dek Standard System waterproof pedestrian balconies, roof decks, walkways, and stairs over plywood
Specification notes OSFM listing 8110-2327:0500 covers a specific Pli-Dek plywood assembly. ESR-2097 also evaluates Con-Dek and multiple walking-deck and roof-covering configurations; match every layer, substrate, fastening, coating, and fire-classification condition to the proposed assembly. Pli-Dek separately publishes an Inclement Weather system with changed details and flashings. Do not substitute it for the Standard configuration without verifying the current OSFM and ESR-2097 scope for the proposed project. Can I use this here Local force Without a place, no local application is inferred.
The Place chip fills the local force for this product.
In this place , this meets the available for local adoption Colorado CWRC Class A deck surface rule.
In this place , this meets the adopted 2006 Utah UWUI Class 1–2 one-hour deck rule.
In this place , this meets the adopted Kittitas IR1–IR2 one-hour deck rule.
The rule and every matching product for the United States
How this product meets each requirement (13)
Requirement constraints (13)
Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
ORSC R327 noncombustible deck surface undocumented Field Required Documented value State Assembly role Assembly role = deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
Austin Zone A noncombustible appendage undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
Colorado CWRC Class A deck surface matched Field Required Documented value State Assembly role Assembly role = deck surface deck surface matched Fire rating Fire rating = class a class a matched
Colorado CWRC noncombustible deck surface undocumented Field Required Documented value State Assembly role Assembly role = deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
2018 IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
Kittitas IR1–IR2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
Kittitas IR1–IR2 one-hour deck matched Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Fire resistance Fire resistance ≥ 60 min 60 min matched
2021 IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 one-hour deck matched Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck surface matched Fire resistance Fire resistance ≥ 60 min 60 min matched
Pli-Dek Standard waterproof walking-deck system. FireApproved. https://fireapproved.com/materials/icp-construction/. Last verified 2026-08-25. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.