Current native
0
exact source areas
Home / Plants / Grow / Tabebuia rosea
Tabebuia rosea
Your local evidence lens
A genus split is not a placement verdict. Set a ZIP to read the local documented split.
The status above is computed from the cited rows below: independent recommendations can support a fire-resistant result, an avoid row can produce keep-away, and disagreement stays visible as conflict. Placement notes preserve each source’s own scheme rather than translating unlike rules into one scale. This is evidence about a plant, not permission to plant it in every part of the defensible space; Zone 0 remains noncombustible.
These are exact U.S. botanical-area records from the cited range source. Native and introduced describe biogeographic relationship, not fire performance or planting approval. Doubtful and extinct rows stay visible but do not count as current presence.
Current native
exact source areas
Current introduced
exact source area
Qualified
doubtful or extinct source rows
FLAMITS: FLAMmability plant traiTS database
“time to flaming (s): 24”
FLAMITS record 4813; Ignitability measurement; plant part wood; fuel dead; predrying yes; device burning bench; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“flaming duration (s): 29”
FLAMITS record 4820; Sustainability measurement; plant part wood; fuel dead; predrying yes; device burning bench; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“time to flaming (s): 56”
FLAMITS record 4827; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“calorific value (kcal/kg): 2340.68”
FLAMITS record 4834; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“maximum sample temperature (°C): 362”
FLAMITS record 4841; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“maximum sample temperature (°C): 70”
FLAMITS record 4848; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“maximum energy flux (kW/m²): 240”
FLAMITS record 4855; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“maximum energy flux (kW/m²): 125”
FLAMITS record 4862; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Haurie2019-1; sampling ND. Primary study Haurie2019: Haurie, L., Giraldo, M. P., Lacasta, A. M., Montón, J., & Sonnier, R. (2019). Influence of different parameters in the fire behaviour of seven hardwood species. Fire safety journal, 107, 193-201.
“time to flaming (s): 8.03”
FLAMITS record 12954; Ignitability measurement; plant part wood; fuel dead; predrying yes; device burning bench; site Sotomayor2017-1; sampling ND. Primary study Sotomayor2017: Sotomayor-Castellanos, J., & Carrillo-Gómez, M. (2017). Comportamiento al fuego de cinco especies mexicanas. Estudio comparativo. Investigación e Ingeniería de la Madera, 13, 4-38.
“burnt biomass (%): 94.71”
FLAMITS record 12959; Consumability measurement; plant part wood; fuel dead; predrying yes; device burning bench; site Sotomayor2017-1; sampling ND. Primary study Sotomayor2017: Sotomayor-Castellanos, J., & Carrillo-Gómez, M. (2017). Comportamiento al fuego de cinco especies mexicanas. Estudio comparativo. Investigación e Ingeniería de la Madera, 13, 4-38.