Current native
32
exact source areas
Home / Plants / Grow / American beech
Fagus grandifolia
Your local evidence lens
A genus split is not a placement verdict. Set a ZIP to read the local documented split.
The status above is computed from the cited rows below: independent recommendations can support a fire-resistant result, an avoid row can produce keep-away, and disagreement stays visible as conflict. Placement notes preserve each source’s own scheme rather than translating unlike rules into one scale. This is evidence about a plant, not permission to plant it in every part of the defensible space; Zone 0 remains noncombustible.
These are exact U.S. botanical-area records from the cited range source. Native and introduced describe biogeographic relationship, not fire performance or planting approval. Doubtful and extinct rows stay visible but do not count as current presence.
Current native
exact source areas
Current introduced
exact source areas
Qualified
doubtful or extinct source rows
Eastern United States Fire Performance Plant Selector
Source prints 5 · single-value meaning unresolved
USDA PLANTS Database — Plant Characteristics
Minimum 2b · no upper limit documented
Eastern United States Fire Performance Plant Selector
“Firewise (1)”
Firewise Landscaping Plants (Maryland, New Jersey, and West Virginia editions)
“relatively resistant to fire”
Listed as Fagus grandifolia (American Beech). The source says listed species exhibit stronger resistance to ignition by wildfires. Source comments: Roots easily damaged by construction, needs good soil
Firewise Landscaping in North Carolina (E05-44596)
“Medium flammability rating”
Firewise Landscaping (OSU Extension Bulletin 921)
“M flammability”
Construction intolerant; climax forest tree.
Virginia Firescapes — Firewise Landscaping for Woodland Homes (430-300)
“M flammability”
Root system is easily damaged by construction. Needs good soils.
Fire-Resistant Landscaping in North Carolina (AG-874)
“medium flammability”
North Carolina Extension Gardener Plant Toolbox — plant profiles and flammability ratings
“medium flammability”
NC Toolbox facet capture lists "Fagus grandifolia" under the medium flammability tag.
FLAMITS: FLAMmability plant traiTS database
“energy flux (kW/m²): 865”
FLAMITS record 5052; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“energy flux (kW/m²): 624”
FLAMITS record 5055; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“energy flux (kW/m²): 194”
FLAMITS record 5058; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“energy flux (kW/m²): 64”
FLAMITS record 5061; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“energy flux (kW/m²): 49”
FLAMITS record 5064; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“energy flux (kW/m²): 29”
FLAMITS record 5067; Combustibility measurement; plant part wood; fuel dead; predrying no; device calorimeter; site Jaskolowski2014-1; sampling ND. Primary study Jaskolowski2014: Jaskólowski, W., Ogrodnik, P., & Lukaszek-Chmielewska, A. (2014). The study of time to ignition of woods under external heat flux by piloted ignition and autoignition. Annals of Warsaw University of Life SciencesSGGW, Forestry and Wood Technology, 86, 133-137.
“flame height (cm): 5.56”
FLAMITS record 9224; Combustibility measurement; plant part litter; fuel all; predrying no; device burning bench; site Mola2014-1; sampling may and june. Primary study Mola2014: Mola, J. M., Varner, J. M., Jules, E. S., & Spector, T. (2014). Altered Community Flammability in Florida's Apalachicola Ravines and Implications for the Persistence of the Endangered Conifer Torreya taxifolia. Plos One, 9, 8.
“flaming duration (s): 40.8”
FLAMITS record 9241; Sustainability measurement; plant part litter; fuel all; predrying no; device burning bench; site Mola2014-1; sampling may and june. Primary study Mola2014: Mola, J. M., Varner, J. M., Jules, E. S., & Spector, T. (2014). Altered Community Flammability in Florida's Apalachicola Ravines and Implications for the Persistence of the Endangered Conifer Torreya taxifolia. Plos One, 9, 8.
“burnt biomass (%): 99.14”
FLAMITS record 9258; Consumability measurement; plant part litter; fuel all; predrying no; device burning bench; site Mola2014-1; sampling may and june. Primary study Mola2014: Mola, J. M., Varner, J. M., Jules, E. S., & Spector, T. (2014). Altered Community Flammability in Florida's Apalachicola Ravines and Implications for the Persistence of the Endangered Conifer Torreya taxifolia. Plos One, 9, 8.
“time to smouldering (s): 177.6”
FLAMITS record 9275; Ignitability measurement; plant part litter; fuel all; predrying no; device burning bench; site Mola2014-1; sampling may and june. Primary study Mola2014: Mola, J. M., Varner, J. M., Jules, E. S., & Spector, T. (2014). Altered Community Flammability in Florida's Apalachicola Ravines and Implications for the Persistence of the Endangered Conifer Torreya taxifolia. Plos One, 9, 8.
“time to flaming (s): 46”
FLAMITS record 12635; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“time to flaming (s): 46”
FLAMITS record 12641; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“time to flaming (s): 39”
FLAMITS record 12647; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“time to flaming (s): 20”
FLAMITS record 12653; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“time to flaming (s): 13”
FLAMITS record 12659; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“time to flaming (s): 18”
FLAMITS record 12665; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 370.6”
FLAMITS record 12671; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 503.8”
FLAMITS record 12677; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 370.6”
FLAMITS record 12683; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 338”
FLAMITS record 12689; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 270.4”
FLAMITS record 12695; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.
“temperature at flaming (°C): 378.9”
FLAMITS record 12701; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Shi2013-1; sampling ND. Primary study Shi2013: Shi, L., & Chew, M. Y. L. (2013). Experimental study of woods under external heat flux by autoignition. Journal of thermal analysis and calorimetry, 111, 1399-1407.