Teton County, Wyoming / Eaves

Eaves in Teton County

Local adoption Teton County adopted 2024 IWUIC. This is the rule.

For Teton County eaves, the requirement for Teton County eaves is IWUIC Class 1 noncombustible eave. On Teton County eaves, it is shown as adopted. Read the Teton County eaves rule, then compare 1 matched Teton County eaves product.

Before Teton County eaves work begins, review Teton County eaves project checks. Those Teton County eaves checks flag scope still to confirm. The Teton County eaves links keep the rule and product list together.

The rule

Adopted “Eaves and soffits shall be protected on the exposed underside by ignition-resistant materials”

IWUIC Class 1 noncombustible eave. The unamended 2024 IWUIC model code permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; Section 503.2 includes noncombustible material in that class.

Products matching Teton County’s adopted requirements

Adopted Product matches below are limited to eaves and trace to the named requirement.

Additional products matching the model-code floor

Model code Product matches below are limited to eaves and trace to the named requirement.

No sourced eaves product in this directory yet matches the model-code floor.

Additional products matching the voluntary program

Voluntary program Product matches below are limited to eaves and trace to the named requirement.

No sourced eaves product in this directory yet matches the voluntary program.

Open checks for this answer

These checks stay open because the sourced instrument leaves them to the official record, not because this page skipped them:

  • Whether the instrument is in force for this project's date.
  • The official boundary that would put a parcel inside the application.
  • Confirmation from the building official for this project.
  • The official hazard class for the lot.
  • The official hazard or WUI map for the lot.
  • Whether this project type is in scope of the instrument.
1 requirement row has no matched product in the directory
  • eaves: iwuic-2024-class-2-solid-eave-enclosure

Every sourced row for this part of the house

  • Adopted IWUIC Class 1 noncombustible eave — The unamended 2024 IWUIC model code permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; Section 503.2 includes noncombustible material in that class.
  • Adopted IWUIC Class 2 solid eave enclosure — The unamended 2024 IWUIC model code specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction.
  • Model code 2018 IWUIC Class 1 noncombustible eave — The unamended 2018 IWUIC permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; Section 503.2 includes noncombustible material in that class.
  • Model code 2018 IWUIC Class 2 solid eave enclosure — The unamended 2018 IWUIC specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction.
  • Model code 2021 IWUIC Class 1 noncombustible eave — The unamended 2021 IWUIC permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; its ignition-resistant-material definition includes noncombustible material.
  • Model code 2021 IWUIC Class 2 solid eave enclosure — The unamended 2021 IWUIC specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction.
  • Voluntary program IBHS Base six-inch wall-base protection — The current IBHS Base standard specifies at least six vertical inches of noncombustible material at the base of exterior walls.