Colorado / Eaves
Eaves in Colorado Local option Not adopted here that we can source. Your county could adopt CWRC 2025.
The rule Available for local adoption “Eaves and soffits shall be protected on the exposed underside by noncombustible material”
Colorado CWRC noncombustible eave. The 2025 Colorado Wildfire Resiliency Code includes noncombustible material as one exposed underside protection path for Class 2 eaves and soffits.
Tick for my house Products matching the published local-adoption option Available for local adoption Product matches below are limited to eaves and trace to the named requirement.
Additional products matching the model-code floor Model code Product matches below are limited to eaves and trace to the named requirement.
No sourced eaves product in this directory yet matches the model-code floor.
Additional products matching the voluntary program Voluntary program Product matches below are limited to eaves and trace to the named requirement.
No sourced eaves product in this directory yet matches the voluntary program.
Every sourced row for this part of the house
Every sourced row for this part of the house Available for local adoption Colorado CWRC noncombustible eave
— The 2025 Colorado Wildfire Resiliency Code includes noncombustible material as one exposed underside protection path for Class 2 eaves and soffits. Tick for my house Model code 2018 IWUIC Class 1 noncombustible eave
— The unamended 2018 IWUIC permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; Section 503.2 includes noncombustible material in that class. Tick for my house Model code 2018 IWUIC Class 2 solid eave enclosure
— The unamended 2018 IWUIC specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction. Tick for my house Model code 2021 IWUIC Class 1 noncombustible eave
— The unamended 2021 IWUIC permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; its ignition-resistant-material definition includes noncombustible material. Tick for my house Model code 2021 IWUIC Class 2 solid eave enclosure
— The unamended 2021 IWUIC specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction. Tick for my house Model code IWUIC Class 1 noncombustible eave
— The unamended 2024 IWUIC model code permits ignition-resistant material on the exposed underside of Class 1 eaves and soffits; Section 503.2 includes noncombustible material in that class. Tick for my house Model code IWUIC Class 2 solid eave enclosure
— The unamended 2024 IWUIC model code specifies solid material at least three-quarter inch thick around combustible eaves, fascias, and soffits in Class 2 construction. Tick for my house Voluntary program IBHS Base six-inch wall-base protection
— The current IBHS Base standard specifies at least six vertical inches of noncombustible material at the base of exterior walls. Tick for my house