Home / Materials / FTX, Thermex, and FSR pressure-treated western red cedar roofing
FTX, Thermex, and FSR pressure-treated western red cedar roofing
This is a listed roofing assembly. Listing 4150-1735:0101. This site cites astm-e108-ul-790. Match the model and orientation. A listing is not a permit.
CAL FIRE OSFM listing 4150-1735:0101 names FTX, Thermex, and FSR pressure-treated No. 1 western red cedar shakes or shingles. QAI CERus-1032 evaluates the FTX and FSR treatment lines in ASTM E108 Class A, B, and C roof assemblies after weathering; the current QAI report does not name Thermex, so no QAI performance claim is extended to that model here.
FTX Class B or Class C treated shakes and shingles
FSR Class B or Class C treated shakes and shingles
Thermex treated shakes and shingles
Named by OSFM listing 4150-1735:0101; not named in current QAI CERus-1032
QAI CERus-1032 names FTX and FSR, not Thermex. Do not apply the QAI classifications or assembly details to a Thermex-labeled bundle without the current product-specific evaluation and listing data sheet.
Class A applies only to the complete QAI assembly using Class B treated FTX or FSR shakes or shingles with the specified noncombustible covering or ASTM D3909 cap sheet. Match the treatment, deck, underlayment, starter course, fasteners, and every installation condition.
QAI CERus-1032 requires removal of existing roof coverings for reroofing and limits treated cedar species, sheathing, underlayment, and fasteners as stated in the report.
OSFM listing is not a permit. The authority having jurisdiction decides.
FTX, Thermex, and FSR pressure-treated western red cedar roofing. FireApproved. https://fireapproved.com/materials/fsr-treatment-inc-model-ftx-and-thermex-and-fsr-pressure-treated-no-1/. Last verified 2026-08-25.