United States / Build / FLAMEFixx treated radiata pine lumber
FLAMEFixx treated radiata pine lumber This is a listed decking assembly. Listing 2520-2400:0001. This site cites OSFM BML. Match the model and orientation.
Listed · limited evidence. Active CAL FIRE BML listing 2520-2400:0001, expires 2027-06-30 (verified against the live BML 2026-08-25). Limited evidence: a single positive channel so far — more programs or documentation may still move this record. This status is computed from the cited evidence by the published rule, never hand-assigned.
▲ CAL FIRE BML 2520-2400:0001 · active
CAL FIRE OSFM listing 2520-2400:0001 covers pressure-impregnated FLAMEFixx radiata pine planks nominally 2 by 6 inches and up to 24 feet long. The product owner documents exterior above- ground structural and deck use, H3 preservative treatment, and testing for Australian bushfire exposures.
Kind: listed-assembly.
Brand: Wood Modification Technologies . Listing evidence: OSFM WUI handbook 2026-08-25.
Page reviewed 2026-08-25. JSON (CC BY 4.0)
Can you use it here?
Enter your ZIP to see which local requirement this meets.
Documents for this product Each link opens the publisher's own copy, so you read the revision they are shipping today.
Documented attributes Each value below points to its field-level manufacturer, official-listing, test-report, or standard-body evidence.
Models named on the listing Model Application FLAMEFixx treated radiata pine plank nominal 2 × 6 inches; lengths up to 24 feet under the BML listing
Specification notes The Australian BAL and AS test evidence is preserved as manufacturer context, not translated into a U.S. test-standard or code-compliance claim. The CAL FIRE BML row is the U.S. listing evidence. Use only above ground and above the flood hazard level; match grade, dimensions, treatment, preservative hazard class, fasteners, oil maintenance, installation instructions, and listing details. Can I use this here How this product meets each requirement (11)
Requirement constraints (11)
Each table compares this product's documented attributes with one published requirement.
The comparison does not change from place to place, so it is printed once.
Austin Zone A noncombustible appendage undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
Colorado CWRC noncombustible deck structure undocumented Field Required Documented value State Assembly role Assembly role = deck structure deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
2018 IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
Kittitas IR1–IR2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
Kittitas IR1–IR2 one-hour deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Fire resistance Fire resistance ≥ 60 min Not documented undocumented
2021 IWUIC Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 noncombustible deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Noncombustible Noncombustible = Yes Not documented undocumented
2006 Utah UWUI Class 1–2 one-hour deck undocumented Field Required Documented value State Assembly role Assembly role is one of deck structure, deck surface deck structure matched Fire resistance Fire resistance ≥ 60 min Not documented undocumented
FLAMEFixx treated radiata pine lumber. FireApproved. https://fireapproved.com/materials/flamefixx-treated-radiata-pine-lumber/. Last verified 2026-08-25. Verify at the source. Every listing number and claim here links to its origin — listings change and local amendments govern, so check the current record before you specify.