How an intumescent vent closes

Last verified 2026-08-25.

An intumescent vent is a listed assembly that includes a strip or coated matrix that swells when heated. That core is not Oregon’s 1/16 to 1/8 inch mesh path, even when the same unit also contains 1/16 inch wire. ICC-ES ESL-1689 describes 26-gauge G90 galvanized steel, an intumescent strip, and 1/16 inch wire mesh as construction inside BrandGuard’s ASTM E2886 listing. Vulcan’s OSFM row 8165-2192:0500 names a hexagonal aluminum matrix with an intumescent coating under the louver cap.

You are holding a vent that looks like a louver. Inside is a strip or a honeycomb. The listing is the model, not the chemistry brand.

The swell-sequence drawing (MECH-007) is not published yet. How to walk ESL-1689 lives on how to read an ICC-ES report. Do not use a house-level hub graphic as this mechanism.

Why it matters

Embers and flame at a vent are a hole problem. Mesh is a size. A baffle turns the path. An intumescent core is supposed to swell and choke that path when it gets hot. Those are different objects. Painting a coating on wood siding is a different object again, and it is not an R327.3.3 wall path. See the coatings finding.

How it works

In normal weather the unit is a ventilation opening. The listing tests ember intrusion and flame intrusion on that specimen, in the orientations Table 1 or the handbook row names. This page does not invent a swell temperature, a close time, or an airflow curve. Those numbers, if they exist, live in the listing or the manufacturer’s instructions.

ESL-1689 still contains 1/16 inch wire. That mesh is part of the listed construction. It is not a reason to skip the listing and call the unit Oregon’s prescriptive mesh path.

The paths

PathWhat you specWhat it is not
Prescriptive mesh1/16–1/8 inch noncombustible corrosion-resistant metal mesh, tight to the frameAn intumescent strip
Listed assembly with intumescent coreThe model on ESL-1689 Table 1 or on the 8165 row“Intumescent vents” as a brand
Listed assembly with a baffle, no swell stripThe model the listing actually describesThis page’s chemistry
Coatings on siding or a field-applied vent paintNot an R327 wall path. Not an 8165 ventThis product

See mesh versus listed vents. Put the model on the drawings. See show the product on the drawings.

What people mix up

  • Treating the 1/16 inch mesh inside ESL-1689 as Oregon’s mesh-only path.
  • Painting intumescent coating on an ordinary louver.
  • Specifying “BrandGuard” from the ESL header instead of a Table 1 model.
  • Assuming every 8165 row is intumescent.
  • Inventing a close time this page did not open.

How to check

  1. Open the listing PDF or handbook row. Find the word intumescent, or a baffle, or mesh only.
  2. Match the model string and the orientation (gable, soffit, eave, foundation).
  3. Do not use a ridge or off-ridge hole as an E2886 specimen. See ridge vents versus ASTM E2886.
  4. If someone proposes a field-applied coating, that is a different conversation. See spray-FRT special inspection.

Limits

This page does not reprint ESL-1689 Table 1. It does not rate airflow. MECH-007 is not published. FireApproved is not the AHJ. A listing is not a permit.

Questions

Is the intumescent strip the same as 1/8 inch mesh?

No. Mesh size is a prescriptive path. An intumescent core is part of a listed assembly tested, for these products, to ASTM E2886. ESL-1689 describes 26-gauge G90 galvanized steel, an intumescent strip, and 1/16 inch wire mesh as construction inside that listed vent. The mesh in the box is not Oregon’s standalone mesh path.

Does it stay open for attic airflow until a fire?

The product is a ventilation opening in normal use. The listing is about ember intrusion and flame intrusion in the lab. This page does not invent a swell temperature or a close time. Read the listing and the manufacturer’s instructions.

Can I paint intumescent coating on an ordinary louver and call it listed?

No. Coatings are not an R327.3.3 wall path, and they are not an 8165 vent. A listed vent is a model. See the coatings finding and spray-FRT special inspection.

Is every 8165 vent intumescent?

No. Some listed vents use baffles, mesh, or a coated matrix. Vulcan’s 8165-2192:0500 handbook row names a hexagonal aluminum matrix with an intumescent coating. BrandGuard’s ESL-1689 names an intumescent strip. Read the row you spec.