Findings

Solid-core wood is a named compliant exterior door in Colorado's wildfire code

code-permits-unexpected

CWRC Section 404.8 gives three exterior-door paths - approved noncombustible construction, solid core wood not less than 1 3/4 inches thick, or a fire protection rating of not less than 20 minutes. Wood is not a fallback or an exception there; it is one of the three named paths. Vehicle access doors are excepted from this section and are instead caught by the perimeter-gap rule in 404.9. This is the mirror image of Oregon barring wood shingle and shake roofs, and the pair is the point - "no wood in the WUI" is wrong in both directions, and what matters is which assembly, at which thickness, in which code.

As of 2026-08-29. JSON (CC BY 4.0)

Sources

Solid-core wood is a named compliant exterior door in Colorado's wildfire code. FireApproved. https://fireapproved.com/findings/colorado-cwrc-solid-core-wood-door/. As of 2026-08-29.