United States / Build / Fire-resistant fencing

Fire-resistant fencing

Program and model No adopted WUI code we can source here. IBHS Wildfire Prepared asks for the inspection measures, and the 2024 IWUIC model says the same floor.

National floor. A ZIP opens the same question at a place where a sourced instrument exists.

The answer

Fire-resistant fencing is about where the fence meets the house. IBHS Wildfire Prepared removes combustible fence, gate, post and retaining-wall material within five feet of the structure or replaces it with noncombustible material; CAL FIRE tells homeowners to replace combustible fencing or gates attached to the house with a noncombustible alternative for the first eight feet; Oregon's State Fire Marshal advises metal gates for fence sections within five feet. The documented metal panels and gates below carry the material fact; distance, posts, attachments and the rest of the parcel are separate facts.

What the sourced rules ask for

For national fencing, the national fencing requirement is IBHS 0–5 foot fence and gate. On national fencing, it is shown as voluntary program. Read the national fencing rule, then compare 25 matched national fencing products.

Review 1 national fencing place answers before choosing among national fencing records. The national fencing links keep the rule, products, and place differences together.

Find what applies near you

Enter a ZIP before browsing the complete evidence. Matching, inherited, and place-neutral records will move first; other places and unmapped application rows will fold into expandable groups. Nothing is removed. All 3 state rule sections remain available.

The rule

Voluntary program “replace with noncombustible material”

IBHS 0–5 foot fence and gate. The 2025 IBHS Base standard removes combustible fence, gate, post, and retaining-wall material within five feet or replaces it with noncombustible material.

Products matching the voluntary program

Voluntary program Product matches below are limited to fencing and trace to the named requirement.

Questions

What fences are fireproof?

None. The rules are about the transition: a noncombustible section, a metal panel, a metal gate or masonry, where the fence approaches the house, so a burning fence does not carry flame into the wall.

What are some non-flammable fence materials?

Metal panels and gates, masonry and other noncombustible materials, which is what IBHS asks for within five feet of the house and CAL FIRE within eight. Those lines apply to the section next to the house.

Does a metal gate make an entire fence safer?

It can interrupt a combustible fence where the fence approaches the house, but the panel, posts, attachments, nearby debris, and the rest of the first five feet remain separate facts. Review the complete transition.

Is a product page enough for a permit or designation?

No. This directory uses public manufacturer documents for product attributes and links those attributes to published requirements. The authority having jurisdiction, program evaluator, or architectural review committee decides the project result.

Does the five-foot distance apply everywhere?

It is an IBHS program line and a common near-home mitigation distance. California public guidance can use different details, and adopted local rules may differ. Identify the document governing the property before selecting a detail.

Where this answer differs