{"id":"cwrc-2025-class-2-solid-core-exterior-door","license":"CC-BY-4.0","data":{"title":"Colorado CWRC Class 2 solid-core exterior-door path","shortName":"Colorado CWRC solid-core door","summary":"The 2025 Colorado Wildfire Resiliency Code includes a solid-core wood exterior-door path with a minimum thickness of 1.75 inches for Class 2 hardening.","framing":"This record covers the door leaf attributes only. Glazing, frame, jamb, gaps, hardware, installation, mapped class, and local adoption remain separate checks.","kind":"code","instrumentId":"cwrc-2025","jurisdiction":"Colorado jurisdictions adopting CWRC in moderate or high mapped wildfire hazard areas","placeIds":["us-co"],"appliesToCategories":["doors"],"quotedText":"solid core wood not less than 1 3/4-inches thick","source":{"title":"2025 Colorado Wildfire Resiliency Code, Section 404.8","url":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","publisher":"Colorado Division of Fire Prevention and Control","sourceType":"official","accessedOn":"2026-08-25T00:00:00.000Z","documentDate":"2025-07-01T00:00:00.000Z"},"constraints":[{"attribute":"assemblyRole","op":"eq","value":"exterior-door"},{"attribute":"solidCore","op":"eq","value":true},{"attribute":"thicknessIn","op":"gte","value":1.75,"unit":"inch"}],"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z"},"applications":[{"id":"cwrc-2025-colorado","title":"Colorado 2025 CWRC local-adoption path","instrumentId":"cwrc-2025","placeId":"us-co","status":"available-for-local-adoption","geographicScope":"mapped-area","scopeSummary":"Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","requirementIds":["cwrc-2025-class-2-20-minute-exterior-door","cwrc-2025-class-2-class-a-deck-surface","cwrc-2025-class-2-multilayered-glazing","cwrc-2025-class-2-noncombustible-deck-structure","cwrc-2025-class-2-noncombustible-deck-surface","cwrc-2025-class-2-noncombustible-eave","cwrc-2025-class-2-noncombustible-exterior-door","cwrc-2025-class-2-noncombustible-exterior-wall","cwrc-2025-class-2-solid-core-exterior-door","cwrc-2025-class-2-wall-base-protection","cwrc-2025-class-a-roof-assembly","cwrc-2025-immediate-zone-hardscape","cwrc-2025-near-structure-fence","cwrc-2025-noncombustible-gutters","cwrc-2025-roof-profile-closure","cwrc-2025-roof-valley-flashing","cwrc-2025-vent-mesh"],"requirementCoverage":"partial","unresolvedPredicates":["local-adoption","official-hazard-map","project-type","official-confirmation"],"source":{"title":"2025 Colorado Wildfire Resiliency Code","url":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","publisher":"Colorado Division of Fire Prevention and Control","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2025-07-01T00:00:00.000Z"},"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z"}],"products":[],"matchContract":"Products appear only when their cited fields satisfy this requirement's normalized constraints. Application scope and unresolved predicates remain separate; an attribute match is not a permit decision."}