{"id":"viburnum-odoratissimum","license":"CC-BY-4.0","data":{"scientificName":"Viburnum odoratissimum","commonNames":["Sweet viburnum"],"taxonRank":"species","acceptedName":"Viburnum odoratissimum","family":"Viburnaceae","ids":{"usdaSymbol":"VIOD3","gbifKey":2888626,"itisTsn":505678,"wikidataQid":"Q12600081","inatTaxonId":357524},"usdaZoneMin":"6a","zoneSource":"fps-2016","states":["DC","DE","MD","NJ","OH","PA","WV"],"hardinessAssertions":[{"minimum":"6","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"viburnum-odoratissimum","sourceTaxon":"Viburnum odoratissimum","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z"}],"plantForm":"tree","matureHeightFt":25,"photo":{"file":"/images/plants/viburnum-odoratissimum.jpg","sourceUrl":"https://www.inaturalist.org/photos/247482212","observationUrl":"https://www.inaturalist.org/observations/144219292","license":"cc-by-sa","attribution":"(c) Greg Tasney, some rights reserved (CC BY-SA)","fetchedOn":"2026-08-23T00:00:00.000Z"},"evidence":[{"source":"fps-eastern-us","verdict":"mixed","verdictRaw":"MODERATELY Firewise (2)","claims":"Pungent foliage. Red fruit. Use as a small tree.","sourcePlacement":{"value":"LZ2","scheme":"fps-landscape-zone"},"edition":"2016-wayback","accessedOn":"2026-08-23T00:00:00.000Z"},{"source":"batista-2013-green-barriers-gtr245","verdict":"mixed","verdictRaw":"Moderately flammable (FV 2)","score":{"value":2,"scale":"valette-0-5-live-shoot"},"claims":"Mean time to ignition 18.2 s; mean flame length 10.64 cm.","plantPart":"shoot","condition":"green","edition":"2013","url":"https://research.fs.usda.gov/download/treesearch/44525.pdf","documentDate":"2013-01-01T00:00:00.000Z","accessedOn":"2026-08-24T00:00:00.000Z"},{"source":"tadaki-kira-fire-classification","verdict":"recommend","verdictRaw":"大","score":{"value":3,"scale":"tadaki-kira-fire-protection-power-0-3"},"claims":"Table 10-2 prints サンゴジュ in the large fire-protection-power class. The Kagoshima reproduction says highly fire-protective trees can slow spread, promote upward dispersal of heat and smoke, and intercept flying embers.","plantPart":"whole-plant","sourcePlacement":{"value":"サンゴジュ — Table 10-2","scheme":"tadaki-kira-1982-fire-protection-power"},"edition":"Hito to Shinrin (1982), Table 10-2; Kagoshima web reproduction","url":"https://www.pref.kagoshima.jp/ah12/kurashi-kankyo/sumai/kankyo/hoshin3/theme10/273.html","documentDate":"1982-11-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 18.2","score":{"value":18.2,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 438; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Batista2012-1; sampling ND. Primary study Batista2012: Batista, C., Biondi, D., França, A., de Assunção, R., Tres, A., Costa, R., ... Kovalsyki, B. (2012). Evaluación de la Inflamabilidad de Árboles y Arbustos Utilizados en la Implementación de Barreras Verdes en el Sur del Brasil. Cuarto Simposio Internacional Sobre Políticas, Planificación y Economía de los Incendios Forestales: Cambio Climático e Incendios Forestales, Ciudad de México, México.","plantPart":"shoot","original":"Batista2012","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 4.74","score":{"value":4.74,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 443; Sustainability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Batista2012-1; sampling ND. Primary study Batista2012: Batista, C., Biondi, D., França, A., de Assunção, R., Tres, A., Costa, R., ... Kovalsyki, B. (2012). Evaluación de la Inflamabilidad de Árboles y Arbustos Utilizados en la Implementación de Barreras Verdes en el Sur del Brasil. Cuarto Simposio Internacional Sobre Políticas, Planificación y Economía de los Incendios Forestales: Cambio Climático e Incendios Forestales, Ciudad de México, México.","plantPart":"shoot","original":"Batista2012","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 2","score":{"value":2,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 448; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Batista2012-1; sampling ND. Primary study Batista2012: Batista, C., Biondi, D., França, A., de Assunção, R., Tres, A., Costa, R., ... Kovalsyki, B. (2012). Evaluación de la Inflamabilidad de Árboles y Arbustos Utilizados en la Implementación de Barreras Verdes en el Sur del Brasil. Cuarto Simposio Internacional Sobre Políticas, Planificación y Economía de los Incendios Forestales: Cambio Climático e Incendios Forestales, Ciudad de México, México.","plantPart":"shoot","original":"Batista2012","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 10.64","score":{"value":10.64,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 453; Combustibility measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Batista2012-1; sampling ND. Primary study Batista2012: Batista, C., Biondi, D., França, A., de Assunção, R., Tres, A., Costa, R., ... Kovalsyki, B. (2012). Evaluación de la Inflamabilidad de Árboles y Arbustos Utilizados en la Implementación de Barreras Verdes en el Sur del Brasil. Cuarto Simposio Internacional Sobre Políticas, Planificación y Economía de los Incendios Forestales: Cambio Climático e Incendios Forestales, Ciudad de México, México.","plantPart":"shoot","original":"Batista2012","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 23.29","score":{"value":23.29,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 492; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Batista2020-1; sampling ND. Primary study Batista2020: Batista, A.C., Biondi, D., & Martini, A. (2020). Flammability of ornamental species for fire management in wildland-urban interface in Paraná state. Floresta, 51, 192-200.","plantPart":"leaf","original":"Batista2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 5.38","score":{"value":5.38,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 493; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Batista2020-1; sampling ND. Primary study Batista2020: Batista, A.C., Biondi, D., & Martini, A. (2020). Flammability of ornamental species for fire management in wildland-urban interface in Paraná state. Floresta, 51, 192-200.","plantPart":"leaf","original":"Batista2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 11.9","score":{"value":11.9,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 494; Combustibility measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Batista2020-1; sampling ND. Primary study Batista2020: Batista, A.C., Biondi, D., & Martini, A. (2020). Flammability of ornamental species for fire management in wildland-urban interface in Paraná state. Floresta, 51, 192-200.","plantPart":"leaf","original":"Batista2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 44","score":{"value":44,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 519; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Batista2020-1; sampling ND. Primary study Batista2020: Batista, A.C., Biondi, D., & Martini, A. (2020). Flammability of ornamental species for fire management in wildland-urban interface in Paraná state. Floresta, 51, 192-200.","plantPart":"leaf","original":"Batista2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 3","score":{"value":3,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 520; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Batista2020-1; sampling ND. Primary study Batista2020: Batista, A.C., Biondi, D., & Martini, A. (2020). Flammability of ornamental species for fire management in wildland-urban interface in Paraná state. Floresta, 51, 192-200.","plantPart":"leaf","original":"Batista2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 23.3","score":{"value":23.3,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 11927; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 5.04","score":{"value":5.04,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 11936; Combustibility measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1","score":{"value":1,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 11945; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 5.4","score":{"value":5.4,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 11954; Sustainability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 32.1","score":{"value":32.1,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 11963; Combustibility measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 48.8","score":{"value":48.8,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 11972; Sustainability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 3877.9","score":{"value":3877.9,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 11981; Combustibility measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Santos2018a-1; sampling ND. Primary study Santos2018a: Santos, J. F. L., Batista, A. C., Tres, A., Tetto, A. F., & Kovalsyki, B. (2018a). Flammability and combustibility of potential species for use as fuel breaks. In: D. X. Viegas, Advances in Forest Fire Research 2018 (pp. 788-793), Portugal, University of Coimbra.","plantPart":"shoot","original":"Santos2018a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 4","score":{"value":4,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 19461; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 2","score":{"value":2,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 19462; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 312.22","score":{"value":312.22,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 19463; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 2.33","score":{"value":2.33,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 19464; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"fire-resistant","ratingReason":"limited-evidence","recommendation":"on-list","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-23T00:00:00.000Z","reviewNotes":"Photo auto-selected (top-voted iNat); human review pending."},"localAssessmentInputs":{"stateDistribution":["DC","DE","MD","NJ","OH","PA","WV"],"nativeStates":[],"rangeAssertions":[{"relation":"documented-occurrence","geography":{"grain":"state","stateCodes":["DC","DE","MD","NJ","OH","PA","WV"]},"provenance":"legacy-field"}],"usdaZoneMin":"6a","usdaZoneMax":null,"hardinessAssertions":[{"minimum":"6","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"viburnum-odoratissimum","sourceTaxon":"Viburnum odoratissimum","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z","provenance":"cited"}],"hardinessSelection":{"status":"unresolved-applicability","assertions":[{"minimum":"6","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"viburnum-odoratissimum","sourceTaxon":"Viburnum odoratissimum","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z","provenance":"cited"}]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"fire-resistant","recommendation":"on-list","fireSourceScopes":[],"firePerformanceConditions":[{"condition":"green","evidence":[{"source":"batista-2013-green-barriers-gtr245","verdict":"mixed","url":"https://research.fs.usda.gov/download/treesearch/44525.pdf","claims":"Mean time to ignition 18.2 s; mean flame length 10.64 cm.","evidenceIndex":1}]}],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}