{"id":"pouteria-ramiflora","license":"CC-BY-4.0","data":{"scientificName":"Pouteria ramiflora","commonNames":["Pouteria ramiflora"],"taxonRank":"species","acceptedName":"Pouteria ramiflora","family":"Sapotaceae","ids":{"gbifKey":2884228},"regions":["Brazil"],"plantForm":"tree","evidence":[{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 73","score":{"value":73,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 10400; Combustibility measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 7.3","score":{"value":7.3,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 10401; Ignitability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 42.4","score":{"value":42.4,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 10402; Sustainability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"smouldering duration (s): 224.5","score":{"value":224.5,"scale":"FLAMITS — smouldering duration (s)"},"claims":"FLAMITS record 10403; Sustainability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 95.38","score":{"value":95.38,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 10404; Consumability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 372.8","score":{"value":372.8,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 10405; Combustibility measurement; plant part litter; fuel all; predrying yes; device burning bench; site Parsons2015-1; sampling august. Primary study Parsons2015: Parsons, A. L., Balch, J. K., de Andrade, R. B., & Brando, P. M. (2015). The role of leaf traits in determining litter flammability of south-eastern Amazon tree species. International journal of wildland fire, 24, 1143-1153.","plantPart":"litter","original":"Parsons2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"mixed-evidence","ratingReason":"limited-evidence","recommendation":"candidate","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z","reviewNotes":"FLAMITS measurements are retained as non-voting evidence; the database publishes no cross-variable directional threshold."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"mixed-evidence","recommendation":"candidate","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}