{"id":"pinus-pinea","license":"CC-BY-4.0","data":{"scientificName":"Pinus pinea","commonNames":["Stone pine"],"taxonRank":"species","acceptedName":"Pinus pinea","family":"Pinaceae","ids":{"usdaSymbol":"PIPI7","gbifKey":5285165,"itisTsn":506604,"wikidataQid":"Q106094","inatTaxonId":63621},"states":["CA"],"invasiveIn":[{"state":"L48","status":"invasive-reported","source":"us-riis"}],"statusAssertions":[{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae9839","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Pinus pinea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dra), https://plants.usda.gov/home/plantProfile?symbol=PIPI7"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"}}],"plantForm":"tree","uses":["ornamental"],"photo":{"file":"/images/plants/pinus-pinea.jpg","sourceUrl":"https://www.inaturalist.org/photos/556082448","observationUrl":"https://www.inaturalist.org/observations/308239777","license":"cc-by","attribution":"(c) zebedeugalinha, some rights reserved (CC BY)","fetchedOn":"2026-08-23T00:00:00.000Z"},"evidence":[{"source":"fenz-low-flammability","verdict":"mixed","verdictRaw":"Moderate flammability","claims":"Moderate flammability classification.","plantPart":"shoot","edition":"2026","url":"https://www.checkitsalright.nz/reduce-your-risk/low-flammability-plants","accessedOn":"2026-08-23T00:00:00.000Z"},{"source":"molina-2017-ignition-index","verdict":"avoid","verdictRaw":"Very flammable (Valette 4)","score":{"value":4,"scale":"valette-0-5-live-leaf"},"claims":"Table 2 reports 137.74% foliar moisture, 13.82 s mean time to ignition, and 15.92 s mean flame duration across 200 live-leaf samples.","plantPart":"leaf","condition":"green","edition":"2017","url":"https://helvia.uco.es/xmlui/bitstream/10396/27022/3/","documentDate":"2017-01-01T00:00:00.000Z","accessedOn":"2026-08-24T00:00:00.000Z"},{"source":"girona-pirojardineria-2020","verdict":"avoid","verdictRaw":"MUY DESACONSEJADA","claims":"Pinus pinea is rated “MUY DESACONSEJADA” by the guide's qualitative IUF garden-suitability method. The method assumes species-specific care and integrates fire evidence with fuel structure, maintenance, origin, invasiveness, and expert fire-service experience.","sourcePlacement":{"value":"not suitable inside or outside the 25-metre maximum-risk zone","scheme":"girona-2020-iuf-25m-suitability"},"edition":"2020 Spanish edition","url":"https://interior.gencat.cat/web/.content/home/030_arees_dactuacio/bombers/foc_forestal/publicacions_tecniques_i_normativa/guies_tecniques/prevencio_i_extincio/2020_Guia_de_pirojardineria_es.pdf","documentDate":"2020-01-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"macalister-2025-sajb-cape-town","verdict":"avoid","verdictRaw":"wildfire hazard","claims":"Official-workbook means across 50 leaf trials: fresh ignition 6.689 s, fresh sustainability 33.54 s, dry ignition 1.845 s, dry sustainability 14.001 s, and combustibility 8.312 mg DW s-1. Published Table 1 observation for the 2021 fire: Partially burned. The discussion explicitly calls the species a wildfire hazard because abundant leaf litter is highly consumable despite low individual-leaf combustibility.","plantPart":"leaf","sourcePlacement":{"value":"Urban zone; Table 1 and deposited raw workbook","scheme":"macalister-2025-leaf-flammability"},"edition":"South African Journal of Botany 184:1163-1173","url":"https://www.sciencedirect.com/science/article/pii/S0254629925004168","documentDate":"2025-09-30T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 1460; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 495","score":{"value":495,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 1654; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 28","score":{"value":28,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 1848; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 15","score":{"value":15,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 2042; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 33.97","score":{"value":33.97,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 2984; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Dimitrakopoulos2011-1; sampling summer. Primary study Dimitrakopoulos2011: Dimitrakopoulos, A. P., Mitsopoulos, I. D., & Kaliva, A. (2011). Short communication. Comparing flammability traits among fire-stricken (low elevation) and non fire- stricken (high elevation) conifer forest species of Europe: a test of the Mutch hypothesis. Forest Systems, 22, 134-137.","plantPart":"leaf","original":"Dimitrakopoulos2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4021.27","score":{"value":4021.27,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 2994; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Dimitrakopoulos2011-1; sampling summer. Primary study Dimitrakopoulos2011: Dimitrakopoulos, A. P., Mitsopoulos, I. D., & Kaliva, A. (2011). Short communication. Comparing flammability traits among fire-stricken (low elevation) and non fire- stricken (high elevation) conifer forest species of Europe: a test of the Mutch hypothesis. Forest Systems, 22, 134-137.","plantPart":"leaf","original":"Dimitrakopoulos2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 247.25","score":{"value":247.25,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 3004; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Dimitrakopoulos2011-1; sampling summer. Primary study Dimitrakopoulos2011: Dimitrakopoulos, A. P., Mitsopoulos, I. D., & Kaliva, A. (2011). Short communication. Comparing flammability traits among fire-stricken (low elevation) and non fire- stricken (high elevation) conifer forest species of Europe: a test of the Mutch hypothesis. Forest Systems, 22, 134-137.","plantPart":"leaf","original":"Dimitrakopoulos2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 8.45","score":{"value":8.45,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 3312; Ignitability measurement; plant part twigs; fuel all; predrying no; device epiradiator; site Essaghi2017-1; sampling january. Primary study Essaghi2017: Essaghi, S., Hachmi, M. H., Yessef, M., Dehhaoui, M., & El Amarty, F. (2017). Assessment of Flammability of Moroccan Forest Fuels: New Approach to Estimate the Flammability Index. Forests, 8, 443.","plantPart":"shoot","original":"Essaghi2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 14.82","score":{"value":14.82,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 3325; Ignitability measurement; plant part twigs; fuel all; predrying no; device epiradiator; site Essaghi2017-1; sampling january. Primary study Essaghi2017: Essaghi, S., Hachmi, M. H., Yessef, M., Dehhaoui, M., & El Amarty, F. (2017). Assessment of Flammability of Moroccan Forest Fuels: New Approach to Estimate the Flammability Index. Forests, 8, 443.","plantPart":"shoot","original":"Essaghi2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4891.56","score":{"value":4891.56,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 3927; Combustibility measurement; plant part twigs; fuel live; predrying yes; device calorimeter; site Gillon1997-1; sampling june to september. Primary study Gillon1997: Gillon, D., Hernando, C., Valette, J.-C., & Joffre, R. (1997). Fast estimation of the calorific values of forest fuels by near infrared-reflectance spectroscopy. Canadian Journal of Forest Research, 27, 760-765.","plantPart":"shoot","original":"Gillon1997","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 5.51","score":{"value":5.51,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 4650; Ignitability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 43","score":{"value":43,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 4656; Combustibility measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 0.26","score":{"value":0.26,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 4663; Sustainability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 50","score":{"value":50,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 4673; Ignitability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 5.51","score":{"value":5.51,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 4681; Ignitability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 0.26","score":{"value":0.26,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 4689; Sustainability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 93","score":{"value":93,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 4695; Consumability measurement; plant part litter; fuel all; predrying no; device burning bench; site Guijarro2002-1; sampling ND. Primary study Guijarro2002: Guijarro, M., Hernando, C., Díez, C., Martínez, E., Madrigal, J., Lampin-Cabaret, C., ... Vega, J. (2002). Flammability of some fuel beds common in the South-European ecosystems.  IV International Conference Forest Fire Research. Coimbra, Portugal.","plantPart":"litter","original":"Guijarro2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 375","score":{"value":375,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 7292; Combustibility measurement; plant part litter; fuel dead; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"litter","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"total heat release (MJ/m²): 19.65","score":{"value":19.65,"scale":"FLAMITS — total heat release (MJ/m²)"},"claims":"FLAMITS record 7298; Combustibility measurement; plant part litter; fuel dead; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"litter","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 6","score":{"value":6,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7304; Ignitability measurement; plant part litter; fuel dead; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"litter","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 68","score":{"value":68,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 7310; Sustainability measurement; plant part litter; fuel dead; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"litter","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 0.06","score":{"value":0.06,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 7316; Combustibility measurement; plant part litter; fuel dead; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"litter","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 81","score":{"value":81,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 7337; Sustainability measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 331","score":{"value":331,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 7357; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9","score":{"value":9,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7377; Ignitability measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 0.06","score":{"value":0.06,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 7397; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"total heat release (MJ/m²): 12.81","score":{"value":12.81,"scale":"FLAMITS — total heat release (MJ/m²)"},"claims":"FLAMITS record 7417; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 23","score":{"value":23,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7748; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 60","score":{"value":60,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7749; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 38","score":{"value":38,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7750; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling november. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22","score":{"value":22,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7751; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling april. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 21","score":{"value":21,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7752; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling june. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 20","score":{"value":20,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7753; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 50","score":{"value":50,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7754; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4805","score":{"value":4805,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 7906; Combustibility measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4878","score":{"value":4878,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 7907; Combustibility measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1","score":{"value":1,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7956; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 3","score":{"value":3,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7957; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 96","score":{"value":96,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8147; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 68","score":{"value":68,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8148; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 8","score":{"value":8,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8149; Ignitability measurement; plant part cones; fuel dead; predrying yes; device epiradiator; site Martin1989-5; sampling november. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8150; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling april. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8151; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling june. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8152; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 95","score":{"value":95,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8153; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-5; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 13.82","score":{"value":13.82,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9304; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 15.93","score":{"value":15.93,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 9322; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 4","score":{"value":4,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 9340; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 17.11","score":{"value":17.11,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9362; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 9.91","score":{"value":9.91,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 9376; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 10.75","score":{"value":10.75,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 9390; Combustibility measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1.49","score":{"value":1.49,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 9404; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 3.16","score":{"value":3.16,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9894; Ignitability measurement; plant part litter; fuel all; predrying yes; device epiradiator; site Ormeno2009-5; sampling june. Primary study Ormeno2009: Ormeno, E., Cespedes, B., Sanchez, I.A., Velasco-Garcia, A., Moreno, J.M., Fernandez, C., & Baldy, V. (2009). The relationship between terpenes and flammability of leaf litter. Forest Ecology and Management, 257, 471-482.","plantPart":"litter","original":"Ormeno2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 14.63","score":{"value":14.63,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 9900; Sustainability measurement; plant part litter; fuel all; predrying yes; device epiradiator; site Ormeno2009-5; sampling june. Primary study Ormeno2009: Ormeno, E., Cespedes, B., Sanchez, I.A., Velasco-Garcia, A., Moreno, J.M., Fernandez, C., & Baldy, V. (2009). The relationship between terpenes and flammability of leaf litter. Forest Ecology and Management, 257, 471-482.","plantPart":"litter","original":"Ormeno2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 329.6","score":{"value":329.6,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 16625; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 27.6","score":{"value":27.6,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 16626; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 52","score":{"value":52,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 16627; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 14.4","score":{"value":14.4,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 16628; Sustainability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 4.7","score":{"value":4.7,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 16629; Consumability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 97","score":{"value":97,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 19839; Ignitability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Ganteaume2009-2; sampling ND. Primary study Ganteaume2009: Ganteaume, A., Lampin-Maillet, C., Guijarro, M., Hernando, C., Jappiot, M., Fonturbel, T., ... Vega, J.A. (2009). Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire, 18, 951-969.","plantPart":"litter","original":"Ganteaume2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 5.51","score":{"value":5.51,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 19840; Ignitability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Ganteaume2009-2; sampling ND. Primary study Ganteaume2009: Ganteaume, A., Lampin-Maillet, C., Guijarro, M., Hernando, C., Jappiot, M., Fonturbel, T., ... Vega, J.A. (2009). Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire, 18, 951-969.","plantPart":"litter","original":"Ganteaume2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 0.26","score":{"value":0.26,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 19841; Sustainability measurement; plant part litter; fuel all; predrying yes; device burning bench; site Ganteaume2009-2; sampling ND. Primary study Ganteaume2009: Ganteaume, A., Lampin-Maillet, C., Guijarro, M., Hernando, C., Jappiot, M., Fonturbel, T., ... Vega, J.A. (2009). Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire, 18, 951-969.","plantPart":"litter","original":"Ganteaume2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 1.23","score":{"value":1.23,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 19842; Combustibility measurement; plant part litter; fuel all; predrying yes; device burning bench; site Ganteaume2009-2; sampling ND. Primary study Ganteaume2009: Ganteaume, A., Lampin-Maillet, C., Guijarro, M., Hernando, C., Jappiot, M., Fonturbel, T., ... Vega, J.A. (2009). Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire, 18, 951-969.","plantPart":"litter","original":"Ganteaume2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 58","score":{"value":58,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 19843; Combustibility measurement; plant part litter; fuel all; predrying yes; device burning bench; site Ganteaume2009-2; sampling ND. Primary study Ganteaume2009: Ganteaume, A., Lampin-Maillet, C., Guijarro, M., Hernando, C., Jappiot, M., Fonturbel, T., ... Vega, J.A. (2009). Spot fires: fuel bed flammability and capability of firebrands to ignite fuel beds. International Journal of Wildland Fire, 18, 951-969.","plantPart":"litter","original":"Ganteaume2009","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"greece-property-fire-regulation-2023","verdict":"avoid","verdictRaw":"ΙΔΙΑΙΤΕΡΑ ΕΥΦΛΕΚΤΑ ΕΝΔΗΜΙΚΑ ΦΥΤΑ — Pinus pinea","claims":"The regulation prints this taxon in its table of particularly flammable endemic trees and shrubs.","plantPart":"whole-plant","sourcePlacement":{"value":"section 5.4.2, Table 2δi","scheme":"greece-2023-particularly-flammable"},"edition":"FEK B 3475/2023","url":"https://www.elinyae.gr/ethniki-nomothesia/ya-oik-ypendaoka5590420192023-fek-3475b-2452023","documentDate":"2023-05-24T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"ogm-yardop-circulars","verdict":"recommend","verdictRaw":"yangına dirençli olduğu tecrübe edilmiş fıstıkçamı","claims":"The YARDOP circular directs managers to preserve, encourage, or use this named taxon in fire-resistant or slow-burning forest and fire-prevention plantings.","plantPart":"whole-plant","sourcePlacement":{"value":"Temel prensipler; Yangın önleyici tesisler","scheme":"yardop-6976-operational-fire-resistant-planting"},"edition":"Circular 6976","url":"https://www.lexpera.com.tr/resmi-gazete/metin/yanan-orman-alanlarinin-rehabilitasyonu-ve-yangina-direncli-ormanlar-tesisi-projesi-20140915-2","documentDate":"2014-09-15T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"highly-flammable","ratingReason":"consensus","recommendation":"avoid","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-23T00:00:00.000Z","reviewNotes":"Photo auto-selected (top-voted iNat); human review pending."},"localAssessmentInputs":{"stateDistribution":["CA"],"nativeStates":[],"rangeAssertions":[{"relation":"documented-occurrence","geography":{"grain":"state","stateCodes":["CA"]},"provenance":"legacy-field"}],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[{"state":"L48","status":"invasive-reported","source":"us-riis"}],"statusAssertions":[{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae9839","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Pinus pinea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dra), https://plants.usda.gov/home/plantProfile?symbol=PIPI7"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"},"provenance":"cited"}],"fireEvidenceClass":"highly-flammable","recommendation":"avoid","fireSourceScopes":[],"firePerformanceConditions":[{"condition":"green","evidence":[{"source":"molina-2017-ignition-index","verdict":"avoid","url":"https://helvia.uco.es/xmlui/bitstream/10396/27022/3/","claims":"Table 2 reports 137.74% foliar moisture, 13.82 s mean time to ignition, and 15.92 s mean flame duration across 200 live-leaf samples.","evidenceIndex":1}]}],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[{"state":"L48","status":"invasive-reported","source":"us-riis-v2"}]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}