{"id":"olea-europaea","license":"CC-BY-4.0","data":{"scientificName":"Olea europaea","commonNames":["Olive"],"taxonRank":"species","acceptedName":"Olea europaea","family":"Oleaceae","ids":{"usdaSymbol":"OLEU","gbifKey":5415040,"itisTsn":32990,"wikidataQid":"Q37083","inatTaxonId":57140},"usdaZoneMin":"8a","zoneSource":"fps-2016","states":["CA","DC","DE","HI","MD","NJ","OH","PA","WV"],"rangeAssertions":[{"relation":"introduced","geography":{"grain":"state","stateCodes":["HI"],"regions":["TDWG level 1 6 — PACIFIC","TDWG level 2 63 — North-Central Pacific","TDWG level 3 HAW — Hawaii"]},"occurrenceStatus":"present","presenceStatus":"extant","source":"wcvp-v16","sourceVersion":"16","asOf":"2026-06-04T00:00:00.000Z"}],"invasiveIn":[{"state":"HI","status":"invasive-reported","source":"us-riis"},{"state":"L48","status":"invasive-reported","source":"us-riis"}],"statusAssertions":[{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["HI"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-HI-Plantae9475","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Olea europaea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dfg), https://plants.usda.gov/home/plantProfile?symbol=OLEU"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"}},{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae9476","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Olea europaea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dfg), https://plants.usda.gov/home/plantProfile?symbol=OLEU"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"}}],"hardinessAssertions":[{"minimum":"8","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"olea-europaea","sourceTaxon":"Olea europaea","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z"}],"plantForm":"tree","matureHeightFt":25,"sun":"full","photo":{"file":"/images/plants/olea-europaea.jpg","sourceUrl":"https://www.inaturalist.org/photos/712174255","observationUrl":"https://www.inaturalist.org/observations/388825391","license":"cc-by","attribution":"(c) zebedeugalinha, some rights reserved (CC BY)","fetchedOn":"2026-08-23T00:00:00.000Z"},"evidence":[{"source":"fps-eastern-us","verdict":"mixed","verdictRaw":"AT RISK Firewise (3)","claims":"Imported small tree in tropical parts of U.S. producing edible fruit after harvesting and processing.","sourcePlacement":{"value":"LZ3","scheme":"fps-landscape-zone"},"edition":"2016-wayback","accessedOn":"2026-08-23T00:00:00.000Z"},{"source":"wyse-2016-nz-60-species","verdict":"mixed","verdictRaw":"Moderate/high flammability category (Fig. 2)","claims":"Shoot category from the paper's cluster analysis; samples were air-dried for 24 hours before testing.","plantPart":"shoot","edition":"2016","url":"https://researcharchive.lincoln.ac.nz/bitstreams/f71e918c-7752-443a-a5ed-8307c07ae635/download","documentDate":"2016-02-25T00:00:00.000Z","accessedOn":"2026-08-24T00:00:00.000Z"},{"source":"molina-2017-ignition-index","verdict":"avoid","verdictRaw":"Very flammable (Valette 4)","score":{"value":4,"scale":"valette-0-5-live-leaf"},"claims":"Table 2 reports 100% foliar moisture, 13.18 s mean time to ignition, and 9.84 s mean flame duration across 200 live-leaf samples.","plantPart":"leaf","condition":"green","edition":"2017","url":"https://helvia.uco.es/xmlui/bitstream/10396/27022/3/","documentDate":"2017-01-01T00:00:00.000Z","accessedOn":"2026-08-24T00:00:00.000Z"},{"source":"henaoui-cistus-tlemcen","verdict":"avoid","verdictRaw":"High flammability — note 3","score":{"value":3,"scale":"henaoui-2013-flammability-note-1-3"},"claims":"Table 1 classifies Olea europaea at flammability note 3; the paper prints its stratum as Tree.","condition":"green","sourcePlacement":{"value":"Table 1","scheme":"henaoui-2013-fresh-material-flammability"},"edition":"European Scientific Journal 9(29)","url":"https://eujournal.org/index.php/esj/article/download/1917/1917/0","documentDate":"2013-10-30T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"lubin-shelly-1997-ucfpl-compilation","verdict":"mixed","verdictRaw":"Conflicting information on fire performance.","claims":"1997 Landscape Vegetation Database row: Olea europea (Arbequina, Olive). Preserved UCFPL transcription marker: C2.","plantPart":"whole-plant","sourcePlacement":{"value":"Chapter 4, Landscape Vegetation Database","scheme":"ucfpl-1997"},"edition":"Internal Report 36.01.137 (July 1997)","url":"https://www.firesafemonterey.org/uploads/1/0/6/5/10653434/uc_forestproductslabdefensiblespaceplantlist_ocr.pdf","documentDate":"1997-07-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 597.85","score":{"value":597.85,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 1065; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Burger2015-1; sampling september. Primary study Burger2015: Burger, N., & Bond, W. J. (2015). Flammability traits of Cape shrubland species with different post-fire recruitment strategies. South African Journal of Botany, 101, 40-48.","plantPart":"shoot","original":"Burger2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 19.84","score":{"value":19.84,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 1094; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Burger2015-1; sampling september. Primary study Burger2015: Burger, N., & Bond, W. J. (2015). Flammability traits of Cape shrubland species with different post-fire recruitment strategies. South African Journal of Botany, 101, 40-48.","plantPart":"shoot","original":"Burger2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 1443; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 456.8","score":{"value":456.8,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 1637; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 12.6","score":{"value":12.6,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 1831; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 13.1","score":{"value":13.1,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 2025; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020a-1; sampling ND. Primary study Cui2020a: Cui, X., Paterson, A. M., Wyse, S. V., Alam, M. A., Maurin, K. J. L., Pieper, R., ... Curran, T. J. (2020a). Shoot flammability of vascular plants is phylogenetically conserved and related to habitat fire-proneness and growth form. Nature Plants, 6, 355-359.","plantPart":"shoot","original":"Cui2020a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4650.33","score":{"value":4650.33,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 3916; Combustibility measurement; plant part twigs; fuel live; predrying yes; device calorimeter; site Gillon1997-1; sampling june to september. Primary study Gillon1997: Gillon, D., Hernando, C., Valette, J.-C., & Joffre, R. (1997). Fast estimation of the calorific values of forest fuels by near infrared-reflectance spectroscopy. Canadian Journal of Forest Research, 27, 760-765.","plantPart":"shoot","original":"Gillon1997","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9.3","score":{"value":9.3,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 4713; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Hachmi2011-1; sampling ND. Primary study Hachmi2011: Hachmi, M. H., Sesbou, A., Benjelloun, H., El Handouz, N., & Bouanane, F. (2011). A Simple Technique to Estimate the Flammability Index of Moroccan Forest Fuels. Journal of Combustion, 2011, 1-11.","plantPart":"shoot","original":"Hachmi2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 13","score":{"value":13,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 4761; Combustibility measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Hachmi2011-1; sampling ND. Primary study Hachmi2011: Hachmi, M. H., Sesbou, A., Benjelloun, H., El Handouz, N., & Bouanane, F. (2011). A Simple Technique to Estimate the Flammability Index of Moroccan Forest Fuels. Journal of Combustion, 2011, 1-11.","plantPart":"shoot","original":"Hachmi2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 10.8","score":{"value":10.8,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 4762; Sustainability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Hachmi2011-1; sampling ND. Primary study Hachmi2011: Hachmi, M. H., Sesbou, A., Benjelloun, H., El Handouz, N., & Bouanane, F. (2011). A Simple Technique to Estimate the Flammability Index of Moroccan Forest Fuels. Journal of Combustion, 2011, 1-11.","plantPart":"shoot","original":"Hachmi2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1.69","score":{"value":1.69,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 4805; Ignitability measurement; plant part twigs; fuel live; predrying no; device epiradiator; site Hachmi2011-1; sampling ND. Primary study Hachmi2011: Hachmi, M. H., Sesbou, A., Benjelloun, H., El Handouz, N., & Bouanane, F. (2011). A Simple Technique to Estimate the Flammability Index of Moroccan Forest Fuels. Journal of Combustion, 2011, 1-11.","plantPart":"shoot","original":"Hachmi2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 40.33","score":{"value":40.33,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 4889; Combustibility measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 59.23","score":{"value":59.23,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 4927; Ignitability measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 99.45","score":{"value":99.45,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 4965; Sustainability measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 10.89","score":{"value":10.89,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 5558; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2014-1; sampling may. Primary study Kauf2014: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2014). Testing Vegetation Flammability: The Problem of Extremely Low Ignition Frequency and Overall Flammability Score. Journal of Combustion, 2014, 1-10.","plantPart":"litter","original":"Kauf2014","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 557.4","score":{"value":557.4,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 5566; Combustibility measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2014-1; sampling may. Primary study Kauf2014: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2014). Testing Vegetation Flammability: The Problem of Extremely Low Ignition Frequency and Overall Flammability Score. Journal of Combustion, 2014, 1-10.","plantPart":"litter","original":"Kauf2014","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 397.4","score":{"value":397.4,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 5574; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2014-1; sampling may. Primary study Kauf2014: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2014). Testing Vegetation Flammability: The Problem of Extremely Low Ignition Frequency and Overall Flammability Score. Journal of Combustion, 2014, 1-10.","plantPart":"litter","original":"Kauf2014","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 38.72","score":{"value":38.72,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 5582; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2014-1; sampling may. Primary study Kauf2014: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2014). Testing Vegetation Flammability: The Problem of Extremely Low Ignition Frequency and Overall Flammability Score. Journal of Combustion, 2014, 1-10.","plantPart":"litter","original":"Kauf2014","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 49.62","score":{"value":49.62,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 5590; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2014-1; sampling may. Primary study Kauf2014: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2014). Testing Vegetation Flammability: The Problem of Extremely Low Ignition Frequency and Overall Flammability Score. Journal of Combustion, 2014, 1-10.","plantPart":"litter","original":"Kauf2014","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 553.47","score":{"value":553.47,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 5597; Combustibility measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-1; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 398.52","score":{"value":398.52,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 5603; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-1; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 12.5","score":{"value":12.5,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 5612; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-1; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 12.18","score":{"value":12.18,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 5613; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-2; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 11.32","score":{"value":11.32,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 5614; Ignitability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-3; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 35.61","score":{"value":35.61,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 5628; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-1; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 38.89","score":{"value":38.89,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 5629; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-2; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 40.1","score":{"value":40.1,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 5630; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-3; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 47.72","score":{"value":47.72,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 5644; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-1; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 50.19","score":{"value":50.19,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 5645; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-2; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 51.32","score":{"value":51.32,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 5646; Sustainability measurement; plant part litter; fuel all; predrying no; device epiradiator; site Kauf2015-3; sampling may, july, september and october. Primary study Kauf2015: Kauf, Z., Fangmeier, A., Rosavec, R., & panjol, . (2015). Seasonal and local differences in leaf litter flammability of six Mediterranean tree species. environmental management, 55, 687-701.","plantPart":"litter","original":"Kauf2015","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5108.26","score":{"value":5108.26,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 6554; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 57","score":{"value":57,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6603; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 56","score":{"value":56,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6604; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 42","score":{"value":42,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6605; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 35","score":{"value":35,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6606; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 27","score":{"value":27,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6607; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 23","score":{"value":23,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6608; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22","score":{"value":22,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6609; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 17","score":{"value":17,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6610; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 15","score":{"value":15,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6611; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 10","score":{"value":10,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6612; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 7.5","score":{"value":7.5,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6613; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9","score":{"value":9,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6614; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 7","score":{"value":7,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6615; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 70.97","score":{"value":70.97,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6666; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 76.53","score":{"value":76.53,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6676; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 444","score":{"value":444,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 6679; Combustibility measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2005-1; sampling ND. Primary study Liodakis2005: Liodakis, S., Vorisis, D., & Agiovlasitis, I. (2005). A method for measuring the relative particle fire hazard properties of forest species. Thermochimica Acta, 437, 150-157.","plantPart":"leaf","original":"Liodakis2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 228","score":{"value":228,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 6685; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2005-1; sampling ND. Primary study Liodakis2005: Liodakis, S., Vorisis, D., & Agiovlasitis, I. (2005). A method for measuring the relative particle fire hazard properties of forest species. Thermochimica Acta, 437, 150-157.","plantPart":"leaf","original":"Liodakis2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 2352","score":{"value":2352,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 6691; Sustainability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2005-1; sampling ND. Primary study Liodakis2005: Liodakis, S., Vorisis, D., & Agiovlasitis, I. (2005). A method for measuring the relative particle fire hazard properties of forest species. Thermochimica Acta, 437, 150-157.","plantPart":"leaf","original":"Liodakis2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 24912","score":{"value":24912,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6697; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2005-1; sampling ND. Primary study Liodakis2005: Liodakis, S., Vorisis, D., & Agiovlasitis, I. (2005). A method for measuring the relative particle fire hazard properties of forest species. Thermochimica Acta, 437, 150-157.","plantPart":"leaf","original":"Liodakis2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5242.11","score":{"value":5242.11,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 6703; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2005-1; sampling ND. Primary study Liodakis2005: Liodakis, S., Vorisis, D., & Agiovlasitis, I. (2005). A method for measuring the relative particle fire hazard properties of forest species. Thermochimica Acta, 437, 150-157.","plantPart":"leaf","original":"Liodakis2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 37","score":{"value":37,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7729; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling may. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 60","score":{"value":60,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7730; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 29","score":{"value":29,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7731; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling august. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 27","score":{"value":27,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7732; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling september. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 27","score":{"value":27,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7733; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 30","score":{"value":30,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7734; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling november. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5459","score":{"value":5459,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 7903; Combustibility measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 2","score":{"value":2,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7951; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling ND. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 26","score":{"value":26,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8128; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling may. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 12","score":{"value":12,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8129; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling july. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 54","score":{"value":54,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8130; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling august. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 97","score":{"value":97,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8131; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling september. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 92","score":{"value":92,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8132; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling october. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 95","score":{"value":95,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 8133; Ignitability measurement; plant part twigs; fuel live; predrying yes; device epiradiator; site Martin1989-1; sampling november. Primary study Martin1989: Martín, E., & Miguel, L. (1989). Inflamabilidad y energía de las especies de sotobosque","plantPart":"shoot","original":"Martin1989","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 190","score":{"value":190,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 8964; Ignitability measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 396","score":{"value":396,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 8981; Combustibility measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smoke (s): 25","score":{"value":25,"scale":"FLAMITS — time to smoke (s)"},"claims":"FLAMITS record 8998; Ignitability measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 253","score":{"value":253,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 9015; Combustibility measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"smouldering duration (s): 150","score":{"value":150,"scale":"FLAMITS — smouldering duration (s)"},"claims":"FLAMITS record 9032; Sustainability measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 357","score":{"value":357,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 9048; Combustibility measurement; plant part leaves; fuel live; predrying yes; device epiradiator; site Massari1998-1; sampling ND. Primary study Massari1998: Massari, G., & Leopaldi, A. (1998). Leaf flammability in Mediterranean species. Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 132, 29-38.","plantPart":"leaf","original":"Massari1998","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 13.18","score":{"value":13.18,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9301; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 9.84","score":{"value":9.84,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 9319; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 4","score":{"value":4,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 9337; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2017-1; sampling summer. Primary study Molina2017: Molina, J. R., Martín, T., Rodríguez Y Silva, F., & Herrera, M. Á. (2017). The ignition index based on flammability of vegetation improves planning in the wildland-urban interface: A case study in Southern Spain. Landscape and Urban Planning, 158, 129-138.","plantPart":"leaf","original":"Molina2017","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 23.91","score":{"value":23.91,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9361; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 8.81","score":{"value":8.81,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 9375; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 8.29","score":{"value":8.29,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 9389; Combustibility measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1.02","score":{"value":1.02,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 9403; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Molina2019-1; sampling july and september. Primary study Molina2019: Molina, J., Lora, A., Prades, C., & Silva, F. R. (2019). Roadside vegetation planning and conservation: New approach to prevent and mitigate wildfires based on fire ignition potential. Forest ecology and management, 444, 163-173.","plantPart":"leaf","original":"Molina2019","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 12.16","score":{"value":12.16,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9703; Ignitability measurement; plant part leaves; fuel live; predrying no; device muffle furnace; site Murray2013-1; sampling march to april. Primary study Murray2013: Murray, B. R., Hardstaff, L. K., & Phillips, M. L. (2013). Differences in leaf flammability, leaf traits and flammability-trait relationships between native and exotic plant species of dry sclerophyll forest. PLoS One, 8, e79205.","plantPart":"leaf","original":"Murray2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 15.66","score":{"value":15.66,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 10497; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling may to june. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 12.66","score":{"value":12.66,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 10498; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling may to june. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 48","score":{"value":48,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 10499; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling may to june. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 4","score":{"value":4,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 10500; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling may to june. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 433.67","score":{"value":433.67,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 12135; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 231.4","score":{"value":231.4,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 12167; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smoke (s): 80","score":{"value":80,"scale":"FLAMITS — time to smoke (s)"},"claims":"FLAMITS record 12201; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smoke (°C): 127.1","score":{"value":127.1,"scale":"FLAMITS — temperature at smoke (°C)"},"claims":"FLAMITS record 12238; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smouldering (s): 194.6","score":{"value":194.6,"scale":"FLAMITS — time to smouldering (s)"},"claims":"FLAMITS record 12274; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smouldering (°C): 299.3","score":{"value":299.3,"scale":"FLAMITS — temperature at smouldering (°C)"},"claims":"FLAMITS record 12310; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 99","score":{"value":99,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 13750; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling august. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 91","score":{"value":91,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 13751; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling december. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 106","score":{"value":106,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 13752; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling march. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 103","score":{"value":103,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 13753; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling may. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 260","score":{"value":260,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13775; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling august. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 287","score":{"value":287,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13776; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling december. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 302","score":{"value":302,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13777; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling march. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 264","score":{"value":264,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13778; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling may. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4155.92","score":{"value":4155.92,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13813; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling august. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4108.15","score":{"value":4108.15,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13814; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling december. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4490.3","score":{"value":4490.3,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13815; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling march. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4347","score":{"value":4347,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13816; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Weise2005-1; sampling may. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 127","score":{"value":127,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13851; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling august. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 165","score":{"value":165,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13852; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling december. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 140","score":{"value":140,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13853; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling march. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 127","score":{"value":127,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 13854; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling may. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 1910.77","score":{"value":1910.77,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13889; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling august. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 2006.31","score":{"value":2006.31,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13890; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling december. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 1958.54","score":{"value":1958.54,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13891; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling march. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 1839.11","score":{"value":1839.11,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 13892; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Weise2005-1; sampling may. Primary study Weise2005: Weise, D. R., White, R. H., Beall, F. C., & Etlinger, M. (2005). Use of the cone calorimeter to detect seasonal differences in selected combustion characteristics of ornamental vegetation. International Journal of Wildland Fire, 14, 321-338.","plantPart":"leaf","original":"Weise2005","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 78","score":{"value":78,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 13981; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 161","score":{"value":161,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 13993; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 145","score":{"value":145,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 14002; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 127","score":{"value":127,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14006; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 258","score":{"value":258,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14007; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 196","score":{"value":196,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14008; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 2101.84","score":{"value":2101.84,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14009; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4561.95","score":{"value":4561.95,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14044; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 2890.03","score":{"value":2890.03,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14054; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White1996-1; sampling ND. Primary study White1996: White, R. H., Weise, D. R., & Frommer, S. (1996). Preliminary evaluation of the flammability of native and ornamental plants with the cone calorimeter.  21st International Conference on Fire Safety. Coimbra, Portugal.","plantPart":"leaf","original":"White1996","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5159.07","score":{"value":5159.07,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14176; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling august. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5111.3","score":{"value":5111.3,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14177; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling november. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4944.11","score":{"value":4944.11,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14178; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling march. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 4896.34","score":{"value":4896.34,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 14179; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling may. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 258","score":{"value":258,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14229; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling august. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 285","score":{"value":285,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14230; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling november. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 279","score":{"value":279,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14231; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling march. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 238","score":{"value":238,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14232; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site White2002-1; sampling may. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 127","score":{"value":127,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14267; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White2002-1; sampling august. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 165","score":{"value":165,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14268; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White2002-1; sampling november. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 126","score":{"value":126,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14269; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White2002-1; sampling march. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 115","score":{"value":115,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 14270; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site White2002-1; sampling may. Primary study White2002: White, R. H., Weise, D. R., Mackes, K., & Dibble, A. C. (2002). Cone calorimeter testing of vegetation--an update. Ninth International Conference on Electrical and Electronic Products. Columbus, Ohio, USA.","plantPart":"leaf","original":"White2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 100","score":{"value":100,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 14359; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Wyse2016-1; sampling ND. Primary study Wyse2016: Wyse, S. V., Perry, G. L. W., O'Connell, D. M., Holland, P. S., Wright, M. J., Hosted, C. L., ... Curran, T. J. (2016). A quantitative assessment of shoot flammability for 60 tree and shrub species supports rankings based on expert opinion. International Journal of Wildland Fire, 25, 466-477.","plantPart":"shoot","original":"Wyse2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 456.8","score":{"value":456.8,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 14419; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Wyse2016-1; sampling ND. Primary study Wyse2016: Wyse, S. V., Perry, G. L. W., O'Connell, D. M., Holland, P. S., Wright, M. J., Hosted, C. L., ... Curran, T. J. (2016). A quantitative assessment of shoot flammability for 60 tree and shrub species supports rankings based on expert opinion. International Journal of Wildland Fire, 25, 466-477.","plantPart":"shoot","original":"Wyse2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 12.6","score":{"value":12.6,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 14479; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Wyse2016-1; sampling ND. Primary study Wyse2016: Wyse, S. V., Perry, G. L. W., O'Connell, D. M., Holland, P. S., Wright, M. J., Hosted, C. L., ... Curran, T. J. (2016). A quantitative assessment of shoot flammability for 60 tree and shrub species supports rankings based on expert opinion. International Journal of Wildland Fire, 25, 466-477.","plantPart":"shoot","original":"Wyse2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 13.1","score":{"value":13.1,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 14539; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Wyse2016-1; sampling ND. Primary study Wyse2016: Wyse, S. V., Perry, G. L. W., O'Connell, D. M., Holland, P. S., Wright, M. J., Hosted, C. L., ... Curran, T. J. (2016). A quantitative assessment of shoot flammability for 60 tree and shrub species supports rankings based on expert opinion. International Journal of Wildland Fire, 25, 466-477.","plantPart":"shoot","original":"Wyse2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 483.18","score":{"value":483.18,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 16417; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Pacheco2022-1; sampling october to november 2022. Primary study Pacheco2022: Pacheco, A. S., Goodman, H. D., Hankenson, L., Fisk, J. J., Ortiz, A., Marinace, H. M., ...  Tng, D. Y. P. (2022). Fighting fire with food: Assessing the flammability of crop plant species for building fire resilient agroforestry systems. in review, preprint.","plantPart":"shoot","original":"Pacheco2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 8.6","score":{"value":8.6,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 16418; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Pacheco2022-1; sampling october to november 2022. Primary study Pacheco2022: Pacheco, A. S., Goodman, H. D., Hankenson, L., Fisk, J. J., Ortiz, A., Marinace, H. M., ...  Tng, D. Y. P. (2022). Fighting fire with food: Assessing the flammability of crop plant species for building fire resilient agroforestry systems. in review, preprint.","plantPart":"shoot","original":"Pacheco2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 6","score":{"value":6,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 16419; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Pacheco2022-1; sampling october to november 2022. Primary study Pacheco2022: Pacheco, A. S., Goodman, H. D., Hankenson, L., Fisk, J. J., Ortiz, A., Marinace, H. M., ...  Tng, D. Y. P. (2022). Fighting fire with food: Assessing the flammability of crop plant species for building fire resilient agroforestry systems. in review, preprint.","plantPart":"shoot","original":"Pacheco2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 2.42","score":{"value":2.42,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 19429; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 6.14","score":{"value":6.14,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 19430; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 255.14","score":{"value":255.14,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 19431; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 2","score":{"value":2,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 19432; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Murray2023-1; sampling ND. Primary study Murray2023: Murray, B. R., Hawthorne, T., Curran, T. J., Krix, D. W., Wallace, M. I., Young, K., ... & Webb, J. K. (2023). Shoot flammability patterns among plant species of the wildlandurban interface in the fire-prone Greater Blue Mountains World Heritage Area. International Journal of Wildland Fire, Online early.","plantPart":"shoot","original":"Murray2023","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"corbett-safer-gardens-2021","verdict":"mixed","verdictRaw":"Olive trees are sometimes included on ‘fire retardant’ lists. However they are very hard to put out once alight.","claims":"The author website preserves the favorable list placement and the adverse sustained-burning observation as a conflict.","plantPart":"whole-plant","original":"Zirogiannis 2009","edition":"2021 book / public sample","url":"https://www.firesafergardens.com/the-plants","documentDate":"2021-01-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"gencat-franges-perimetrals","verdict":"recommend","verdictRaw":"Cal mantenir prioritàriament les espècies menys inflamables. — Olivera, ullastre — Olea europaea","claims":"The guide says to maintain this printed taxon first among the less-flammable species when opening and maintaining perimeter protection strips.","plantPart":"whole-plant","sourcePlacement":{"value":"page 4 species-selection panel","scheme":"catalonia-perimeter-strip-maintain-remove"},"edition":"2025 web edition","url":"https://www.diba.cat/documents/d/incendis/diba_franges_web","documentDate":"2025-01-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"highly-flammable","ratingReason":"consensus","recommendation":"avoid","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-23T00:00:00.000Z","reviewNotes":"Photo auto-selected (top-voted iNat); human review pending."},"localAssessmentInputs":{"stateDistribution":["CA","DC","DE","HI","MD","NJ","OH","PA","WV"],"nativeStates":[],"rangeAssertions":[{"relation":"introduced","geography":{"grain":"state","stateCodes":["HI"],"regions":["TDWG level 1 6 — PACIFIC","TDWG level 2 63 — North-Central Pacific","TDWG level 3 HAW — Hawaii"]},"occurrenceStatus":"present","presenceStatus":"extant","source":"wcvp-v16","sourceVersion":"16","asOf":"2026-06-04T00:00:00.000Z","provenance":"cited"},{"relation":"documented-occurrence","geography":{"grain":"state","stateCodes":["CA","DC","DE","HI","MD","NJ","OH","PA","WV"]},"provenance":"legacy-field"}],"usdaZoneMin":"8a","usdaZoneMax":null,"hardinessAssertions":[{"minimum":"8","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"olea-europaea","sourceTaxon":"Olea europaea","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z","provenance":"cited"}],"hardinessSelection":{"status":"unresolved-applicability","assertions":[{"minimum":"8","interpretation":"ambiguous-single-value","precision":"whole-zone","zoneMapping":"source-stated","applicability":"uncertain","applicabilityNotes":"The recovered selector prints one Cold Hardiness Zone value but does not define it as a minimum threshold or a one-zone range.","source":"fps-eastern-us","sourceRecordId":"olea-europaea","sourceTaxon":"Olea europaea","taxonMatch":"exact","sourcePlacement":"Cold Hardiness Zone field in the recovered selector record","sourceVersion":"2016-wayback","asOf":"2026-08-26T00:00:00.000Z","provenance":"cited"}]},"invasiveIn":[{"state":"HI","status":"invasive-reported","source":"us-riis"},{"state":"L48","status":"invasive-reported","source":"us-riis"}],"statusAssertions":[{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["HI"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-HI-Plantae9475","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Olea europaea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dfg), https://plants.usda.gov/home/plantProfile?symbol=OLEU"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"},"provenance":"cited"},{"status":"invasive","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae9476","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Olea europaea","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"D2","label":"invasive (category D2)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021dfg), https://plants.usda.gov/home/plantProfile?symbol=OLEU"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"},"provenance":"cited"}],"fireEvidenceClass":"highly-flammable","recommendation":"avoid","fireSourceScopes":[{"source":"lubin-shelly-1997-ucfpl-compilation","sourceName":"Defensible Space Landscaping in the Urban/Wildland Interface: A Compilation of Fire Performance Ratings of Residential Landscape Plants","sourceUrl":"https://www.firesafemonterey.org/uploads/1/0/6/5/10653434/uc_forestproductslabdefensiblespaceplantlist_ocr.pdf","geography":{"grain":"state","stateCodes":["CA"]},"completeness":"partial","reviewStatus":"reviewed","scope":"The UC Forest Products Laboratory says the guide covers properties of common California landscaping plants and was prepared for California fire agencies. FireApproved publishes 130 exact owners at historical California publication scope. The report is a 1997 compilation, not a current endorsement, site rating, or independent test of every row.","sourceVersion":"UCFPL-Internal-Report-36.01.137-1997-07","asOf":"1997-07-01T00:00:00.000Z"}],"firePerformanceConditions":[{"condition":"green","evidence":[{"source":"molina-2017-ignition-index","verdict":"avoid","url":"https://helvia.uco.es/xmlui/bitstream/10396/27022/3/","claims":"Table 2 reports 100% foliar moisture, 13.18 s mean time to ignition, and 9.84 s mean flame duration across 200 live-leaf samples.","evidenceIndex":2},{"source":"henaoui-cistus-tlemcen","verdict":"avoid","url":"https://eujournal.org/index.php/esj/article/download/1917/1917/0","claims":"Table 1 classifies Olea europaea at flammability note 3; the paper prints its stratum as Tree.","evidenceIndex":3}]}],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[{"state":"HI","status":"invasive-reported","source":"us-riis-v2"},{"state":"L48","status":"invasive-reported","source":"us-riis-v2"}]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}