{"id":"manoao-colensoi","license":"CC-BY-4.0","data":{"scientificName":"Manoao colensoi","commonNames":["Manoao colensoi"],"taxonRank":"species","acceptedName":"Manoao colensoi","family":"Podocarpaceae","ids":{"gbifKey":2687870},"regions":["New Zealand"],"plantForm":"tree","evidence":[{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smoke (°C): 165.18","score":{"value":165.18,"scale":"FLAMITS — temperature at smoke (°C)"},"claims":"FLAMITS record 8428; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smoke (°C): 206","score":{"value":206,"scale":"FLAMITS — temperature at smoke (°C)"},"claims":"FLAMITS record 8429; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 286.78","score":{"value":286.78,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 8643; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 274.12","score":{"value":274.12,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 8644; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature increase rate (°C/s): 14.98","score":{"value":14.98,"scale":"FLAMITS — temperature increase rate (°C/s)"},"claims":"FLAMITS record 8858; Combustibility measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature increase rate (°C/s): 11.98","score":{"value":11.98,"scale":"FLAMITS — temperature increase rate (°C/s)"},"claims":"FLAMITS record 8859; Combustibility measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Mason2016-5; sampling summer. Primary study Mason2016: Mason, N. W. H., Frazao, C., Buxton, R. P., & Richardson, S. J. (2016). Fire form and function: evidence for exaptive flammability in the New Zealand flora. Plant Ecology, 217, 645-659.","plantPart":"leaf","original":"Mason2016","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"mixed-evidence","ratingReason":"limited-evidence","recommendation":"candidate","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z","reviewNotes":"FLAMITS measurements are retained as non-voting evidence; the database publishes no cross-variable directional threshold."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"mixed-evidence","recommendation":"candidate","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}