{"id":"fagus-crenata","license":"CC-BY-4.0","data":{"scientificName":"Fagus crenata","commonNames":["Fagus crenata"],"taxonRank":"species","acceptedName":"Fagus crenata","family":"Fagaceae","ids":{"gbifKey":2882300},"regions":["Japan"],"plantForm":"tree","evidence":[{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 17","score":{"value":17,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18842; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 262","score":{"value":262,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18861; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 97","score":{"value":97,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18862; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 58","score":{"value":58,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18863; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 30","score":{"value":30,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18864; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22","score":{"value":22,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18865; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 89","score":{"value":89,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18866; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 45","score":{"value":45,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18867; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 31","score":{"value":31,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18868; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 96","score":{"value":96,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18869; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 56","score":{"value":56,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18870; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 32","score":{"value":32,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18871; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 20","score":{"value":20,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18872; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 131","score":{"value":131,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18873; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 86","score":{"value":86,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18874; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 51","score":{"value":51,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18875; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 34","score":{"value":34,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18876; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 155","score":{"value":155,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18877; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 59","score":{"value":59,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18878; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 31","score":{"value":31,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18879; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22","score":{"value":22,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18880; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 94","score":{"value":94,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18881; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 55","score":{"value":55,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18882; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 34","score":{"value":34,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 18883; Ignitability measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 12.5","score":{"value":12.5,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18976; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 10.9","score":{"value":10.9,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18977; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 11.6","score":{"value":11.6,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18978; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 13.2","score":{"value":13.2,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18979; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 14.9","score":{"value":14.9,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18980; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 11.3","score":{"value":11.3,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18981; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 12.4","score":{"value":12.4,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18982; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 14.7","score":{"value":14.7,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18983; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.9","score":{"value":8.9,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18984; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 9","score":{"value":9,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18985; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 11","score":{"value":11,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18986; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 13.1","score":{"value":13.1,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18987; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.5","score":{"value":8.5,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18988; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.9","score":{"value":8.9,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18989; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 10","score":{"value":10,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18990; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 10.8","score":{"value":10.8,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18991; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.4","score":{"value":8.4,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18992; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.1","score":{"value":8.1,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18993; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 10","score":{"value":10,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18994; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 11.3","score":{"value":11.3,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18995; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 8.2","score":{"value":8.2,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18996; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 9.4","score":{"value":9.4,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18997; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate per area (g/m² s): 10","score":{"value":10,"scale":"FLAMITS — mass loss rate per area (g/m² s)"},"claims":"FLAMITS record 18998; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 135","score":{"value":135,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19091; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 116","score":{"value":116,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19092; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 119","score":{"value":119,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19093; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 161","score":{"value":161,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19094; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 151","score":{"value":151,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19095; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 116","score":{"value":116,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19096; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 146","score":{"value":146,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19097; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 141","score":{"value":141,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19098; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 94","score":{"value":94,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19099; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 96","score":{"value":96,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19100; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 124","score":{"value":124,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19101; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 143","score":{"value":143,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19102; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 90","score":{"value":90,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19103; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 95","score":{"value":95,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19104; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 114","score":{"value":114,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19105; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 114","score":{"value":114,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19106; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 91","score":{"value":91,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19107; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 92","score":{"value":92,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19108; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 111","score":{"value":111,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19109; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 127","score":{"value":127,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19110; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 94","score":{"value":94,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19111; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 111","score":{"value":111,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19112; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"energy flux (kW/m²): 112","score":{"value":112,"scale":"FLAMITS — energy flux (kW/m²)"},"claims":"FLAMITS record 19113; Combustibility measurement; plant part wood; fuel dead; predrying yes; device calorimeter; site Harada2001-1; sampling ND. Primary study Harada2001: Harada, T. (2001). Time to ignition, heat release rate and fire endurance time of wood in cone calorimeter test. Fire Materials, 25, 1617.","original":"Harada2001","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"mixed-evidence","ratingReason":"limited-evidence","recommendation":"candidate","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z","reviewNotes":"FLAMITS measurements are retained as non-voting evidence; the database publishes no cross-variable directional threshold."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"mixed-evidence","recommendation":"candidate","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}