{"id":"dracophyllum-rosmarinifolium","license":"CC-BY-4.0","data":{"scientificName":"Dracophyllum rosmarinifolium","commonNames":["Common grass tree","Inaka"],"taxonRank":"species","acceptedName":"Dracophyllum rosmarinifolium","family":"Ericaceae","ids":{"gbifKey":4010419,"wikidataQid":"Q15376605","inatTaxonId":401529},"regions":["New Zealand"],"plantForm":"shrub","photo":{"file":"/images/plants/dracophyllum-rosmarinifolium.jpg","sourceUrl":"https://www.inaturalist.org/photos/350799867","observationUrl":"https://www.inaturalist.org/observations/198971309","license":"cc0","attribution":"no rights reserved","fetchedOn":"2026-08-23T00:00:00.000Z"},"evidence":[{"source":"fenz-low-flammability","verdict":"avoid","verdictRaw":"High flammability","claims":"High flammability classification.","plantPart":"shoot","edition":"2026","url":"https://www.checkitsalright.nz/reduce-your-risk/low-flammability-plants","accessedOn":"2026-08-23T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.8","score":{"value":1.8,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 2103; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020b-7; sampling summer and autumn. Primary study Cui2020b: Cui, X., Paterson, A. M., Alam, M. A., Wyse, S. V., Marshall, K., Perry, G. L. W., & Curran, T. J. (2020b). Shoot-level flammability across the Dracophyllum (Ericaceae) phylogeny: evidence for flammability being an emergent property in a land with little fire. New Phytologist, 228, 95-105","plantPart":"shoot","original":"Cui2020b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 619.8","score":{"value":619.8,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 2124; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020b-7; sampling summer and autumn. Primary study Cui2020b: Cui, X., Paterson, A. M., Alam, M. A., Wyse, S. V., Marshall, K., Perry, G. L. W., & Curran, T. J. (2020b). Shoot-level flammability across the Dracophyllum (Ericaceae) phylogeny: evidence for flammability being an emergent property in a land with little fire. New Phytologist, 228, 95-105","plantPart":"shoot","original":"Cui2020b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 70.9","score":{"value":70.9,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 2145; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020b-7; sampling summer and autumn. Primary study Cui2020b: Cui, X., Paterson, A. M., Alam, M. A., Wyse, S. V., Marshall, K., Perry, G. L. W., & Curran, T. J. (2020b). Shoot-level flammability across the Dracophyllum (Ericaceae) phylogeny: evidence for flammability being an emergent property in a land with little fire. New Phytologist, 228, 95-105","plantPart":"shoot","original":"Cui2020b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 70.2","score":{"value":70.2,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 2166; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2020b-7; sampling summer and autumn. Primary study Cui2020b: Cui, X., Paterson, A. M., Alam, M. A., Wyse, S. V., Marshall, K., Perry, G. L. W., & Curran, T. J. (2020b). Shoot-level flammability across the Dracophyllum (Ericaceae) phylogeny: evidence for flammability being an emergent property in a land with little fire. New Phytologist, 228, 95-105","plantPart":"shoot","original":"Cui2020b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.6","score":{"value":1.6,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15511; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-1; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 680.1","score":{"value":680.1,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15512; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-1; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 93.9","score":{"value":93.9,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15513; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-1; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 76.3","score":{"value":76.3,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15514; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-1; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 2.7","score":{"value":2.7,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15515; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-2; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 439.5","score":{"value":439.5,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15516; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-2; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 44.5","score":{"value":44.5,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15517; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-2; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 33.8","score":{"value":33.8,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15518; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-2; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 2.1","score":{"value":2.1,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15519; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-3; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 674.8","score":{"value":674.8,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15520; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-3; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 105","score":{"value":105,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15521; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-3; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 86.3","score":{"value":86.3,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15522; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-3; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 2.1","score":{"value":2.1,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15523; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-4; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 677.3","score":{"value":677.3,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15524; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-4; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 77","score":{"value":77,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15525; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-4; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 86.4","score":{"value":86.4,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15526; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-4; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.3","score":{"value":1.3,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15527; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-5; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 456","score":{"value":456,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15528; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-5; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 23.1","score":{"value":23.1,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15529; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-5; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 36.4","score":{"value":36.4,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15530; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-5; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.2","score":{"value":1.2,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15531; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-6; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 724.4","score":{"value":724.4,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15532; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-6; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 81.3","score":{"value":81.3,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15533; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-6; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 88.8","score":{"value":88.8,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15534; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-6; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.7","score":{"value":1.7,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15535; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-7; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 618.3","score":{"value":618.3,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15536; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-7; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 81.1","score":{"value":81.1,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15537; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-7; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 75.6","score":{"value":75.6,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15538; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-7; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1.7","score":{"value":1.7,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 15539; Ignitability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-8; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum flame temperature (°C): 674.5","score":{"value":674.5,"scale":"FLAMITS — maximum flame temperature (°C)"},"claims":"FLAMITS record 15540; Combustibility measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-8; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 55.8","score":{"value":55.8,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 15541; Sustainability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-8; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 75.6","score":{"value":75.6,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 15542; Consumability measurement; plant part branches; fuel all; predrying yes; device grill; site Cui2022-8; sampling ND. Primary study Cui2022: Cui, X., Paterson, A. M., Perry, G. L., Wyse, S. V., Alam, M. A., Huang, C., ... & Curran, T. J. (2022). Intraspecific variation in shoot flammability in Dracophyllum rosmarinifolium is not predicted by habitat environmental conditions. Forest Ecosystems, 9, 100017.","plantPart":"shoot","original":"Cui2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"highly-flammable","ratingReason":"limited-evidence","recommendation":"avoid","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-23T00:00:00.000Z","reviewNotes":"Photo auto-selected (top-voted iNat); human review pending."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"highly-flammable","recommendation":"avoid","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}