{"id":"daphne-gnidium","license":"CC-BY-4.0","data":{"scientificName":"Daphne gnidium","commonNames":["Flax-leaved daphne"],"taxonRank":"species","acceptedName":"Daphne gnidium","family":"Thymelaeaceae","ids":{"gbifKey":7311306},"regions":["Algeria","Spain"],"plantForm":"shrub","evidence":[{"source":"madrigal-2013-bench-scale-live-fuels","verdict":"not-rated","verdictRaw":"Flammability variables for the species studied","claims":"Live-fuel comparison at 50 kW/m², 10 g fixed dry mass, 20 kg/m³ bulk density, piloted ignition, and FMC 104%. Table 1 mean (repeatability SD): TTI 33 (4) s; PHRR 105 (18) kW/m²; AEHC 4.41 (0.71) MJ/kg; MLR 0.18 (0.02) g/s; THR 2.46 (0.65) MJ/m². Kruskall–Wallis p values by species: TTI 0.0153; PHRR 0.0216; AEHC 0.0307; MLR 0.0300; THR 0.0156. The paper gives no overall species class or composite rank.","plantPart":"shoot","condition":"green","edition":"Journal of Fire Sciences 31(2)","url":"https://journals.sagepub.com/doi/10.1177/0734904112458244","documentDate":"2012-09-12T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"girona-pirojardineria-2020","verdict":"recommend","verdictRaw":"MUY RECOMENDADA","claims":"Daphne gnidium is rated “MUY RECOMENDADA” by the guide's qualitative IUF garden-suitability method. The method assumes species-specific care and integrates fire evidence with fuel structure, maintenance, origin, invasiveness, and expert fire-service experience.","sourcePlacement":{"value":"suitable inside or outside the 25-metre maximum-risk zone","scheme":"girona-2020-iuf-25m-suitability"},"edition":"2020 Spanish edition","url":"https://interior.gencat.cat/web/.content/home/030_arees_dactuacio/bombers/foc_forestal/publicacions_tecniques_i_normativa/guies_tecniques/prevencio_i_extincio/2020_Guia_de_pirojardineria_es.pdf","documentDate":"2020-01-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"henaoui-cistus-tlemcen","verdict":"mixed","verdictRaw":"Moderate flammability — note 2","score":{"value":2,"scale":"henaoui-2013-flammability-note-1-3"},"claims":"Table 1 classifies Daphne gnidium at flammability note 2; the paper prints its stratum as Shrub.","condition":"green","sourcePlacement":{"value":"Table 1","scheme":"henaoui-2013-fresh-material-flammability"},"edition":"European Scientific Journal 9(29)","url":"https://eujournal.org/index.php/esj/article/download/1917/1917/0","documentDate":"2013-10-30T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 21.86","score":{"value":21.86,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 4881; Combustibility measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 85.64","score":{"value":85.64,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 4919; Ignitability measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 127.93","score":{"value":127.93,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 4957; Sustainability measurement; plant part twigs; fuel live; predrying yes; device infrared burner; site Henaoui2013-1; sampling spring. Primary study Henaoui2013: Henaoui, S. E. -A., Bouazza, M., & Amara, M. (2013). The fire risk of the plant groupings with Cistus in the area of Tlemcen (Western Algeria). European Scientific Journal, 9, 84-103.","plantPart":"shoot","original":"Henaoui2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 82","score":{"value":82,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 7325; Sustainability measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 353","score":{"value":353,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 7345; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 3","score":{"value":3,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7365; Ignitability measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 0.06","score":{"value":0.06,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 7385; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"total heat release (MJ/m²): 25.87","score":{"value":25.87,"scale":"FLAMITS — total heat release (MJ/m²)"},"claims":"FLAMITS record 7405; Combustibility measurement; plant part twigs; fuel live; predrying no; device calorimeter; site Madrigal2011a-1; sampling ND. Primary study Madrigal2011a: Madrigal, J., Guijarro, M., Hernando, C., Díez, C., & Marino, E. (2011a). Effective Heat of Combustion for Flaming Combustion of Mediterranean Forest Fuels. Fire Technology, 47, 461-474.","plantPart":"shoot","original":"Madrigal2011a","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 33","score":{"value":33,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 7500; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Madrigal2013-1; sampling june to september. Primary study Madrigal2013: Madrigal, J., Hernando, C., & Guijarro, M. (2013). A new bench-scale methodology for evaluating the flammability of live forest fuels. Journal of Fire Sciences, 31, 131-142.","plantPart":"leaf","original":"Madrigal2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum energy flux (kW/m²): 105","score":{"value":105,"scale":"FLAMITS — maximum energy flux (kW/m²)"},"claims":"FLAMITS record 7504; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Madrigal2013-1; sampling june to september. Primary study Madrigal2013: Madrigal, J., Hernando, C., & Guijarro, M. (2013). A new bench-scale methodology for evaluating the flammability of live forest fuels. Journal of Fire Sciences, 31, 131-142.","plantPart":"leaf","original":"Madrigal2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 4.41","score":{"value":4.41,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 7508; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Madrigal2013-1; sampling june to september. Primary study Madrigal2013: Madrigal, J., Hernando, C., & Guijarro, M. (2013). A new bench-scale methodology for evaluating the flammability of live forest fuels. Journal of Fire Sciences, 31, 131-142.","plantPart":"leaf","original":"Madrigal2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"total heat release (MJ/m²): 2.46","score":{"value":2.46,"scale":"FLAMITS — total heat release (MJ/m²)"},"claims":"FLAMITS record 7512; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Madrigal2013-1; sampling june to september. Primary study Madrigal2013: Madrigal, J., Hernando, C., & Guijarro, M. (2013). A new bench-scale methodology for evaluating the flammability of live forest fuels. Journal of Fire Sciences, 31, 131-142.","plantPart":"leaf","original":"Madrigal2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 1053.31","score":{"value":1053.31,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 7516; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Madrigal2013-1; sampling june to september. Primary study Madrigal2013: Madrigal, J., Hernando, C., & Guijarro, M. (2013). A new bench-scale methodology for evaluating the flammability of live forest fuels. Journal of Fire Sciences, 31, 131-142.","plantPart":"leaf","original":"Madrigal2013","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 589.33","score":{"value":589.33,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 12132; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 578","score":{"value":578,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 12149; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 430.8","score":{"value":430.8,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 12162; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 375","score":{"value":375,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 12183; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smoke (s): 86.5","score":{"value":86.5,"scale":"FLAMITS — time to smoke (s)"},"claims":"FLAMITS record 12196; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smoke (s): 95.6","score":{"value":95.6,"scale":"FLAMITS — time to smoke (s)"},"claims":"FLAMITS record 12217; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smoke (°C): 146.27","score":{"value":146.27,"scale":"FLAMITS — temperature at smoke (°C)"},"claims":"FLAMITS record 12233; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smoke (°C): 156","score":{"value":156,"scale":"FLAMITS — temperature at smoke (°C)"},"claims":"FLAMITS record 12254; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smouldering (s): 283.4","score":{"value":283.4,"scale":"FLAMITS — time to smouldering (s)"},"claims":"FLAMITS record 12269; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to smouldering (s): 263.2","score":{"value":263.2,"scale":"FLAMITS — time to smouldering (s)"},"claims":"FLAMITS record 12290; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smouldering (°C): 429.6","score":{"value":429.6,"scale":"FLAMITS — temperature at smouldering (°C)"},"claims":"FLAMITS record 12305; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-1; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at smouldering (°C): 435.2","score":{"value":435.2,"scale":"FLAMITS — temperature at smouldering (°C)"},"claims":"FLAMITS record 12326; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Saura2010-2; sampling august. Primary study Saura2010: Saura-Mas, S., Paula, S., Pausas, J. G,. & Lloret, F. (2010). Fuel loading and flammability in the Mediterranean Basin woody species with different post-fire regenerative strategies. International Journal of Wildland Fire, 19, 783.","plantPart":"leaf","original":"Saura2010","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"gencat-franges-perimetrals","verdict":"recommend","verdictRaw":"Cal mantenir prioritàriament les espècies menys inflamables. — Matapoll — Daphne gnidium","claims":"The guide says to maintain this printed taxon first among the less-flammable species when opening and maintaining perimeter protection strips.","plantPart":"whole-plant","sourcePlacement":{"value":"page 4 species-selection panel","scheme":"catalonia-perimeter-strip-maintain-remove"},"edition":"2025 web edition","url":"https://www.diba.cat/documents/d/incendis/diba_franges_web","documentDate":"2025-01-01T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"fire-resistant","ratingReason":"limited-evidence","recommendation":"on-list","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z"},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"fire-resistant","recommendation":"on-list","fireSourceScopes":[],"firePerformanceConditions":[{"condition":"green","evidence":[{"source":"madrigal-2013-bench-scale-live-fuels","verdict":"not-rated","url":"https://journals.sagepub.com/doi/10.1177/0734904112458244","claims":"Live-fuel comparison at 50 kW/m², 10 g fixed dry mass, 20 kg/m³ bulk density, piloted ignition, and FMC 104%. Table 1 mean (repeatability SD): TTI 33 (4) s; PHRR 105 (18) kW/m²; AEHC 4.41 (0.71) MJ/kg; MLR 0.18 (0.02) g/s; THR 2.46 (0.65) MJ/m². Kruskall–Wallis p values by species: TTI 0.0153; PHRR 0.0216; AEHC 0.0307; MLR 0.0300; THR 0.0156. The paper gives no overall species class or composite rank.","evidenceIndex":0},{"source":"henaoui-cistus-tlemcen","verdict":"mixed","url":"https://eujournal.org/index.php/esj/article/download/1917/1917/0","claims":"Table 1 classifies Daphne gnidium at flammability note 2; the paper prints its stratum as Shrub.","evidenceIndex":2}]}],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}