{"id":"cistus-incanus","license":"CC-BY-4.0","data":{"scientificName":"Cistus incanus","commonNames":["Cistus incanus"],"taxonRank":"species","acceptedName":"Cistus incanus","family":"Cistaceae","ids":{"gbifKey":2874028},"regions":["Greece","Italy"],"statusAssertions":[{"status":"introduced-established","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae7169","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Cistus incanus","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"C3","label":"established (category C3)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021aij), https://plants.usda.gov/home/plantProfile?symbol=CIIN80"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"}}],"plantForm":"shrub","evidence":[{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5182.36","score":{"value":5182.36,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 6555; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 61","score":{"value":61,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6616; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 48","score":{"value":48,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6617; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 43","score":{"value":43,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6618; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 37","score":{"value":37,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6619; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 31","score":{"value":31,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6620; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 29","score":{"value":29,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6621; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 27","score":{"value":27,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6622; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 21","score":{"value":21,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6623; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 20","score":{"value":20,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6624; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 17","score":{"value":17,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6625; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 12","score":{"value":12,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6626; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 11","score":{"value":11,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6627; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 74.78","score":{"value":74.78,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6663; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 64.11","score":{"value":64.11,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6670; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-1; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 3683","score":{"value":3683,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 6745; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2006b-1; sampling ND. Primary study Liodakis2006b: Liodakis, S., & Kakardakis, T. (2006b). Measuring the Particle Flammability of Forest Species from Wildland/Urban Inter-face (WUI) near Athens by Thermal Analysis. First International Symposium on Environment Identities and Mediterranean Area. Corte-Ajaccio, France","plantPart":"leaf","original":"Liodakis2006b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 1596","score":{"value":1596,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6751; Ignitability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2006b-1; sampling ND. Primary study Liodakis2006b: Liodakis, S., & Kakardakis, T. (2006b). Measuring the Particle Flammability of Forest Species from Wildland/Urban Inter-face (WUI) near Athens by Thermal Analysis. First International Symposium on Environment Identities and Mediterranean Area. Corte-Ajaccio, France","plantPart":"leaf","original":"Liodakis2006b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"maximum sample temperature (°C): 300.9","score":{"value":300.9,"scale":"FLAMITS — maximum sample temperature (°C)"},"claims":"FLAMITS record 6758; Combustibility measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2006b-1; sampling ND. Primary study Liodakis2006b: Liodakis, S., & Kakardakis, T. (2006b). Measuring the Particle Flammability of Forest Species from Wildland/Urban Inter-face (WUI) near Athens by Thermal Analysis. First International Symposium on Environment Identities and Mediterranean Area. Corte-Ajaccio, France","plantPart":"leaf","original":"Liodakis2006b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 372","score":{"value":372,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 6765; Sustainability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2006b-1; sampling ND. Primary study Liodakis2006b: Liodakis, S., & Kakardakis, T. (2006b). Measuring the Particle Flammability of Forest Species from Wildland/Urban Inter-face (WUI) near Athens by Thermal Analysis. First International Symposium on Environment Identities and Mediterranean Area. Corte-Ajaccio, France","plantPart":"leaf","original":"Liodakis2006b","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9.15","score":{"value":9.15,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6889; Ignitability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame intensity (kW/m): 76.01","score":{"value":76.01,"scale":"FLAMITS — flame intensity (kW/m)"},"claims":"FLAMITS record 6895; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 273.01","score":{"value":273.01,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 6901; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 94.33","score":{"value":94.33,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6907; Consumability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 6.33","score":{"value":6.33,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 6913; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 2.14","score":{"value":2.14,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 6919; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 6.63","score":{"value":6.63,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6924; Ignitability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 0.11","score":{"value":0.11,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 6930; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 117.2","score":{"value":117.2,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 6936; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 2.5","score":{"value":2.5,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 6942; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame intensity (kW/m): 86.42","score":{"value":86.42,"scale":"FLAMITS — flame intensity (kW/m)"},"claims":"FLAMITS record 6948; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 83.37","score":{"value":83.37,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6954; Consumability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 5.8","score":{"value":5.8,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6960; Ignitability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"rate of burning spread (cm/s): 0.14","score":{"value":0.14,"scale":"FLAMITS — rate of burning spread (cm/s)"},"claims":"FLAMITS record 6966; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flaming duration (s): 98.67","score":{"value":98.67,"scale":"FLAMITS — flaming duration (s)"},"claims":"FLAMITS record 6972; Sustainability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 3","score":{"value":3,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 6978; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame intensity (kW/m): 144.58","score":{"value":144.58,"scale":"FLAMITS — flame intensity (kW/m)"},"claims":"FLAMITS record 6984; Combustibility measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 83.39","score":{"value":83.39,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6990; Consumability measurement; plant part leaves; fuel live; predrying yes; device burning bench; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1","score":{"value":1,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 6998; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling spring. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 2","score":{"value":2,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7005; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling summer. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 2","score":{"value":2,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7012; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling autumn. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 2","score":{"value":2,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7019; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 3","score":{"value":3,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7026; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 4","score":{"value":4,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 7033; Ignitability measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2011-1; sampling all seasons. Primary study Liodakis2011: Liodakis, S., Agiovlasitis, I.P., Kakardakis, T., Tzamtzis, N., Vorisis, D., & Lois, E. (2011). Determining hazard risk indices for Mediterranean forest species based on particle flammability properties. Fire Safety Journal, 46, 116-124.","plantPart":"leaf","original":"Liodakis2011","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22.88","score":{"value":22.88,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 10521; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling july to august. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 10","score":{"value":10,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 10522; Sustainability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling july to august. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"ignition frequency (%): 9","score":{"value":9,"scale":"FLAMITS — ignition frequency (%)"},"claims":"FLAMITS record 10523; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling july to august. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flammability value: 1","score":{"value":1,"scale":"FLAMITS — flammability value"},"claims":"FLAMITS record 10524; Ignitability measurement; plant part leaves; fuel live; predrying no; device epiradiator; site Petriccione2006-1; sampling july to august. Primary study Petriccione2006: Petriccione, M. (2006). Infiammabilità della lettiera di diverse specie vegetali di ambiente mediterráneo. Tesi Di Dottorato. Università Degli Studi Di Napoli Federico II.","plantPart":"leaf","original":"Petriccione2006","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"mixed-evidence","ratingReason":"limited-evidence","recommendation":"candidate","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z","reviewNotes":"FLAMITS measurements are retained as non-voting evidence; the database publishes no cross-variable directional threshold."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[{"status":"introduced-established","channel":"ecological","geography":{"grain":"aggregate-region","regions":["L48"]},"source":"us-riis-v2","sourceRecordId":"USRIIS-L48-Plantae7169","sourceVersion":"2.0 (November 2022)","asOf":"2022-10-23T00:00:00.000Z","sourceModified":"2017-11-21T00:00:00.000Z","sourceTaxon":{"name":"Cistus incanus","rank":"species","rawRank":"Species"},"sourceDesignation":{"code":"C3","label":"established (category C3)"},"associatedReferences":["USDA Natural Resources Conservation Service (NRCS) PLANTS Database (2021aij), https://plants.usda.gov/home/plantProfile?symbol=CIIN80"],"taxonProjection":{"basis":"exact-taxon","notes":"exact source identifier, rank, family, and scientific/accepted name"},"provenance":"cited"}],"fireEvidenceClass":"mixed-evidence","recommendation":"candidate","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}