{"id":"arbutus-andrachne","license":"CC-BY-4.0","data":{"scientificName":"Arbutus andrachne","commonNames":["Arbutus andrachne"],"taxonRank":"species","acceptedName":"Arbutus andrachne","family":"Ericaceae","ids":{"gbifKey":4170901},"regions":["Greece","Turkey"],"plantForm":"shrub","evidence":[{"source":"flamits","verdict":"not-rated","verdictRaw":"calorific value (kcal/kg): 5302.34","score":{"value":5302.34,"scale":"FLAMITS — calorific value (kcal/kg)"},"claims":"FLAMITS record 6548; Combustibility measurement; plant part leaves; fuel live; predrying yes; device calorimeter; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 43","score":{"value":43,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6628; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 32","score":{"value":32,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6629; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 29","score":{"value":29,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6630; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 22","score":{"value":22,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6631; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 21","score":{"value":21,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6632; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 18","score":{"value":18,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6633; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 16","score":{"value":16,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6634; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 15","score":{"value":15,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6635; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 11","score":{"value":11,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6636; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9","score":{"value":9,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6637; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 9","score":{"value":9,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 6638; Ignitability measurement; plant part leaves; fuel live; predrying yes; device muffle furnace; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 73.98","score":{"value":73.98,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6664; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 69.64","score":{"value":69.64,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 6672; Consumability measurement; plant part leaves; fuel live; predrying yes; device thermal analyzer; site Liodakis2002-2; sampling january. Primary study Liodakis2002: Liodakis, S., Bakirtzis, D., & Lois, E. (2002). TG and autoignition studies on forest fuels. Journal of Thermal Analysis and Calorimetry, 69, 519-528.","plantPart":"leaf","original":"Liodakis2002","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 896","score":{"value":896,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 9186; Ignitability measurement; plant part leaves; fuel dead; predrying no; device muffle furnace; site Michelaki2020-1; sampling spring. Primary study Michelaki2020: Michelaki, C., Fyllas, N. M., Galanidis, A., Aloupi, M., Evangelou, E., Arianoutsou, M., & Dimitrakopoulos, P. G. (2020). Adaptive flammability syndromes in thermo-Mediterranean vegetation, captured by alternative resource-use strategies. Science of The Total Environment, 718, 137437.","plantPart":"leaf","original":"Michelaki2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 322","score":{"value":322,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 9187; Sustainability measurement; plant part leaves; fuel dead; predrying no; device muffle furnace; site Michelaki2020-1; sampling spring. Primary study Michelaki2020: Michelaki, C., Fyllas, N. M., Galanidis, A., Aloupi, M., Evangelou, E., Arianoutsou, M., & Dimitrakopoulos, P. G. (2020). Adaptive flammability syndromes in thermo-Mediterranean vegetation, captured by alternative resource-use strategies. Science of The Total Environment, 718, 137437.","plantPart":"leaf","original":"Michelaki2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"mass loss rate (g/s): 0","score":{"value":0,"scale":"FLAMITS — mass loss rate (g/s)"},"claims":"FLAMITS record 9188; Combustibility measurement; plant part leaves; fuel dead; predrying no; device muffle furnace; site Michelaki2020-1; sampling spring. Primary study Michelaki2020: Michelaki, C., Fyllas, N. M., Galanidis, A., Aloupi, M., Evangelou, E., Arianoutsou, M., & Dimitrakopoulos, P. G. (2020). Adaptive flammability syndromes in thermo-Mediterranean vegetation, captured by alternative resource-use strategies. Science of The Total Environment, 718, 137437.","plantPart":"leaf","original":"Michelaki2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"estimated burnt biomass (%): 93.6","score":{"value":93.6,"scale":"FLAMITS — estimated burnt biomass (%)"},"claims":"FLAMITS record 9189; Consumability measurement; plant part leaves; fuel dead; predrying no; device muffle furnace; site Michelaki2020-1; sampling spring. Primary study Michelaki2020: Michelaki, C., Fyllas, N. M., Galanidis, A., Aloupi, M., Evangelou, E., Arianoutsou, M., & Dimitrakopoulos, P. G. (2020). Adaptive flammability syndromes in thermo-Mediterranean vegetation, captured by alternative resource-use strategies. Science of The Total Environment, 718, 137437.","plantPart":"leaf","original":"Michelaki2020","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"temperature at flaming (°C): 335.7","score":{"value":335.7,"scale":"FLAMITS — temperature at flaming (°C)"},"claims":"FLAMITS record 16655; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"time to flaming (s): 16.1","score":{"value":16.1,"scale":"FLAMITS — time to flaming (s)"},"claims":"FLAMITS record 16656; Ignitability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"flame height (cm): 52.2","score":{"value":52.2,"scale":"FLAMITS — flame height (cm)"},"claims":"FLAMITS record 16657; Combustibility measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burning duration (s): 10.4","score":{"value":10.4,"scale":"FLAMITS — burning duration (s)"},"claims":"FLAMITS record 16658; Sustainability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"},{"source":"flamits","verdict":"not-rated","verdictRaw":"burnt biomass (%): 7","score":{"value":7,"scale":"FLAMITS — burnt biomass (%)"},"claims":"FLAMITS record 16659; Consumability measurement; plant part leaves; fuel live; predrying no; device calorimeter; site Guney2022-1; sampling may and september 2017. Primary study Guney2022: Güney, C. O., Sar?, A., Cekim, H. O., Küçüksille, E. U., ?entürk, Ö., Gülsoy, S., & Özkan, K. (2022). An advanced approach for leaf flammability index estimation. International journal of wildland fire, 31, 277-290.","plantPart":"leaf","original":"Guney2022","edition":"Dryad version 9","url":"https://doi.org/10.5061/dryad.h18931zr3","documentDate":"2023-12-22T00:00:00.000Z","accessedOn":"2026-08-25T00:00:00.000Z"}],"flammabilityClass":"mixed-evidence","ratingReason":"limited-evidence","recommendation":"candidate","author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-25T00:00:00.000Z","reviewNotes":"FLAMITS measurements are retained as non-voting evidence; the database publishes no cross-variable directional threshold."},"localAssessmentInputs":{"stateDistribution":[],"nativeStates":[],"rangeAssertions":[],"usdaZoneMin":null,"usdaZoneMax":null,"hardinessAssertions":[],"hardinessSelection":{"status":"none","assertions":[]},"invasiveIn":[],"statusAssertions":[],"fireEvidenceClass":"mixed-evidence","recommendation":"candidate","fireSourceScopes":[],"firePerformanceConditions":[],"maintenanceAssertions":[],"maintenanceConditions":null,"regulatoryReviews":{},"seedReviews":{}},"legacyCompatibilityProjection":{"nativeStates":[],"invasiveIn":[]},"localAssessmentContract":"Compare each dimension separately. State noxious-weed seed designations are material-scoped and never become non-seed plant restrictions, ecological-invasive findings, nursery restrictions, alternatives, product evidence, or fire votes. Introduced/established context is not an invasive warning. Minimum-only hardiness has no inferred maximum; canonical source-temperature conversion is validated and contradictory applicable rows project no primary zone. L48 context applies only to conterminous states and is never exact-state status. Fire-performance conditions are not maintenance advice. FEIS fire-ecology context does not vote in the plant classification. Absence of a status row is not regulatory clearance."}