{"id":"us-wy-teton","name":"Teton County","kind":"county","parent":"us-wy","license":"CC-BY-4.0","placeNode":"/places/us-wy-teton.json","statePage":"/places/wyoming/","record":{"type":"local-code","topics":["construction","fire-access"],"sources":[{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"},{"title":"WUI Information for Contractors","url":"https://tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}],"lastVerified":"2026-08-26T00:00:00.000Z"},"applications":[{"id":"iwuic-2024-teton-county","title":"Unincorporated Teton County 2024 IWUIC application","instrumentId":"iwuic-2024","placeId":"us-wy-teton","status":"active","geographicScope":"unincorporated-county","scopeSummary":"Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","adoptedOn":"2025-01-07T00:00:00.000Z","effectiveOn":"2025-02-01T00:00:00.000Z","requirementIds":["iwuic-2024-class-1-2-20-minute-exterior-door","iwuic-2024-class-1-2-class-a-roof-assembly","iwuic-2024-class-1-2-multilayered-glazing","iwuic-2024-class-1-2-noncombustible-deck","iwuic-2024-class-1-2-noncombustible-exterior-door","iwuic-2024-class-1-2-noncombustible-exterior-wall","iwuic-2024-class-1-2-solid-core-exterior-door","iwuic-2024-class-1-noncombustible-eave","iwuic-2024-class-1-wall-base-protection","iwuic-2024-class-2-solid-eave-enclosure","iwuic-2024-class-3-class-b-roof-assembly","iwuic-2024-noncombustible-gutters","iwuic-2024-roof-profile-closure","iwuic-2024-roof-valley-flashing","iwuic-2024-vent-mesh"],"requirementCoverage":"complete","requirementCoverageSummary":"All 15 normalized model material rows were reviewed against the enacted local amendments; this is complete only for that model crosswalk, not full-code normalization or a finding that every class row applies to one project.","requirementScopes":[{"requirementId":"iwuic-2024-class-1-2-20-minute-exterior-door","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This exterior-door path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.9","505.9"]},{"requirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This Class A roof path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.2","505.2"]},{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This multilayered-glazing path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.8","505.8"]},{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This noncombustible appendage path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.7","505.7"]},{"requirementId":"iwuic-2024-class-1-2-noncombustible-exterior-door","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This noncombustible exterior-door path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.9","505.9"]},{"requirementId":"iwuic-2024-class-1-2-noncombustible-exterior-wall","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This noncombustible exterior-wall path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.5","505.5"]},{"requirementId":"iwuic-2024-class-1-2-solid-core-exterior-door","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2"],"scopeSummary":"This solid-core exterior-door path applies only when Fire/EMS assigns IR1 or IR2 construction.","sourceSections":["504.9","505.9"]},{"requirementId":"iwuic-2024-class-1-noncombustible-eave","scopeKeys":["ignition-resistant-class-1"],"scopeSummary":"This eave path applies only when Fire/EMS assigns IR1 construction.","sourceSections":["503.2.1","504.3"]},{"requirementId":"iwuic-2024-class-1-wall-base-protection","scopeKeys":["ignition-resistant-class-1"],"scopeSummary":"This wall-base path applies only when Fire/EMS assigns IR1 construction.","sourceSections":["504.5.1"]},{"requirementId":"iwuic-2024-class-2-solid-eave-enclosure","scopeKeys":["ignition-resistant-class-2"],"scopeSummary":"This solid eave-enclosure path applies only when Fire/EMS assigns IR2 construction.","sourceSections":["505.3"]},{"requirementId":"iwuic-2024-class-3-class-b-roof-assembly","scopeKeys":["ignition-resistant-class-3"],"scopeSummary":"This Class B roof path applies only when Fire/EMS assigns IR3 construction.","sourceSections":["506.2"]},{"requirementId":"iwuic-2024-noncombustible-gutters","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2","ignition-resistant-class-3"],"scopeSummary":"This gutter-and-downspout path applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","sourceSections":["504.4","505.4","506.4"]},{"requirementId":"iwuic-2024-roof-profile-closure","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2","ignition-resistant-class-3"],"scopeSummary":"This roof-profile closure applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","sourceSections":["504.2","505.2","506.2"]},{"requirementId":"iwuic-2024-roof-valley-flashing","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2","ignition-resistant-class-3"],"scopeSummary":"This valley-flashing path applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","sourceSections":["504.2.1","505.2.1","506.2.1"]},{"requirementId":"iwuic-2024-vent-mesh","scopeKeys":["ignition-resistant-class-1","ignition-resistant-class-2","ignition-resistant-class-3"],"scopeSummary":"This vent-mesh path applies after Fire/EMS assigns IR1, IR2, or IR3 construction.","sourceSections":["504.10.2","505.10.2","506.5"]}],"requirementCrosswalk":[{"modelRequirementId":"iwuic-2024-class-1-2-20-minute-exterior-door","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized 20-minute exterior-door atom.","sourceSections":["504.9","505.9"]},{"modelRequirementId":"iwuic-2024-class-1-2-class-a-roof-assembly","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized Class A roof atom.","sourceSections":["504.2","505.2"]},{"modelRequirementId":"iwuic-2024-class-1-2-multilayered-glazing","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized multilayered-glazing atom.","sourceSections":["504.8","505.8"]},{"modelRequirementId":"iwuic-2024-class-1-2-noncombustible-deck","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized noncombustible-appendage atom.","sourceSections":["504.7","505.7"]},{"modelRequirementId":"iwuic-2024-class-1-2-noncombustible-exterior-door","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized noncombustible-door atom.","sourceSections":["504.9","505.9"]},{"modelRequirementId":"iwuic-2024-class-1-2-noncombustible-exterior-wall","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized noncombustible-wall atom.","sourceSections":["504.5","505.5"]},{"modelRequirementId":"iwuic-2024-class-1-2-solid-core-exterior-door","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized solid-core-door atom.","sourceSections":["504.9","505.9"]},{"modelRequirementId":"iwuic-2024-class-1-noncombustible-eave","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized noncombustible-eave atom.","sourceSections":["503.2.1","504.3"]},{"modelRequirementId":"iwuic-2024-class-1-wall-base-protection","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized wall-base atom.","sourceSections":["504.5.1"]},{"modelRequirementId":"iwuic-2024-class-2-solid-eave-enclosure","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized solid-eave atom.","sourceSections":["505.3"]},{"modelRequirementId":"iwuic-2024-class-3-class-b-roof-assembly","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized Class B roof atom.","sourceSections":["506.2"]},{"modelRequirementId":"iwuic-2024-noncombustible-gutters","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized noncombustible-gutter atom.","sourceSections":["504.4","505.4","506.4"]},{"modelRequirementId":"iwuic-2024-roof-profile-closure","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized roof-profile atom.","sourceSections":["504.2","505.2","506.2"]},{"modelRequirementId":"iwuic-2024-roof-valley-flashing","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized valley-flashing atom.","sourceSections":["504.2.1","505.2.1","506.2.1"]},{"modelRequirementId":"iwuic-2024-vent-mesh","disposition":"adopted-unchanged","replacementRequirementIds":[],"scopeSummary":"The local Chapter 5 amendments do not change the normalized prescriptive vent-mesh atom.","sourceSections":["504.10.2","505.10.2","506.5"]}],"map":{"status":"linked-official-tool","summary":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","url":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167","source":{"title":"Teton County WUI map","url":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},"projectTriggers":[{"summary":"Except for the stated exemptions, the Building Departments require the Fire/EMS WUI review and permit number before accepting a permit submittal.","sourceSections":["Submitting for IWUIC review"],"source":{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"summary":"A one-story detached tool shed, storage shed, playhouse, or similar accessory structure is exempt only when floor area does not exceed 120 square feet and it is more than 50 feet from the nearest adjacent structure.","sourceSections":["WUI review exemptions"],"source":{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"summary":"A strictly interior project is exempt only when it does not affect exterior components, including windows, doors, or decking; Fire/EMS separately states interior-only projects do not require a WUI permit.","sourceSections":["WUI review exemptions"],"source":{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"summary":"Re-roofing does not require a WUI permit under the current Fire/EMS guidance; applicants are told to contact Fire/EMS before submittal when project status is unclear.","sourceSections":["WUI review exemptions"],"source":{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"summary":"The local Section 101.5 exception requires additions or alterations of no more than 500 square feet to conform as new construction except for Section 602, subject to its sprinkler condition.","sourceSections":["101.5"],"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}}],"localAmendments":[{"kind":"exception","section":"101.5","summary":"The resolution adds a local rule for additions or alterations of no more than 500 square feet, with a Section 602 sprinkler exception.","source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"kind":"addition","section":"503.2.1.1","summary":"The resolution prohibits wood shake shingles or siding inside the mapped WUI.","source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"kind":"deletion","section":"503.2.3","summary":"The resolution strikes the model wood-roof-covering section while adding its separate local wood prohibition.","source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"kind":"exception","section":"504.10.3","summary":"The resolution allows cold-roof ventilation when vents meet Section 504.10.1 for all ignition-resistant construction types.","source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}}],"supportingSources":[{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}],"unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"},"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-26T00:00:00.000Z"}],"requirements":[{"id":"iwuic-2024-class-1-noncombustible-eave","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1 noncombustible eave","url":"/requirements/iwuic-2024-class-1-noncombustible-eave/"},{"id":"iwuic-2024-class-1-wall-base-protection","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1 wall-base protection","url":"/requirements/iwuic-2024-class-1-wall-base-protection/"},{"id":"iwuic-2024-class-1-2-20-minute-exterior-door","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 20-minute door","url":"/requirements/iwuic-2024-class-1-2-20-minute-exterior-door/"},{"id":"iwuic-2024-class-1-2-class-a-roof-assembly","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 Class A roof","url":"/requirements/iwuic-2024-class-1-2-class-a-roof-assembly/"},{"id":"iwuic-2024-class-1-2-multilayered-glazing","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 multilayered glazing","url":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"id":"iwuic-2024-class-1-2-noncombustible-deck","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 noncombustible deck","url":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"id":"iwuic-2024-class-1-2-noncombustible-exterior-door","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 noncombustible door","url":"/requirements/iwuic-2024-class-1-2-noncombustible-exterior-door/"},{"id":"iwuic-2024-class-1-2-noncombustible-exterior-wall","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 noncombustible wall","url":"/requirements/iwuic-2024-class-1-2-noncombustible-exterior-wall/"},{"id":"iwuic-2024-class-1-2-solid-core-exterior-door","instrumentId":"iwuic-2024","shortName":"IWUIC Class 1–2 solid-core door","url":"/requirements/iwuic-2024-class-1-2-solid-core-exterior-door/"},{"id":"iwuic-2024-class-2-solid-eave-enclosure","instrumentId":"iwuic-2024","shortName":"IWUIC Class 2 solid eave enclosure","url":"/requirements/iwuic-2024-class-2-solid-eave-enclosure/"},{"id":"iwuic-2024-class-3-class-b-roof-assembly","instrumentId":"iwuic-2024","shortName":"IWUIC Class 3 Class B roof","url":"/requirements/iwuic-2024-class-3-class-b-roof-assembly/"},{"id":"iwuic-2024-noncombustible-gutters","instrumentId":"iwuic-2024","shortName":"IWUIC noncombustible gutters","url":"/requirements/iwuic-2024-noncombustible-gutters/"},{"id":"iwuic-2024-roof-profile-closure","instrumentId":"iwuic-2024","shortName":"IWUIC roof-profile eave closure","url":"/requirements/iwuic-2024-roof-profile-closure/"},{"id":"iwuic-2024-roof-valley-flashing","instrumentId":"iwuic-2024","shortName":"IWUIC valley flashing","url":"/requirements/iwuic-2024-roof-valley-flashing/"},{"id":"iwuic-2024-vent-mesh","instrumentId":"iwuic-2024","shortName":"IWUIC vent mesh","url":"/requirements/iwuic-2024-vent-mesh/"}],"claims":{"exact":[{"id":"guide:covering-vs-assembly:27","anchor":"local-us-wy-teton-covering-vs-assembly-27","place":"Teton County 2024 IWUIC (local overlay)","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"The County 2024 Fire Code Resolution adopts 2024 IWUIC Chapter 5 on unincorporated lands. Amendment 503.2.1.1 prohibits wood shake shingles or siding in the mapped WUI but does not amend §504.2. The reviewed crosswalk keeps a Class A roof assembly tested to ASTM E108 or UL 790 in IR1 and IR2, and Class B or better in IR3. Confirm the map, project, and assigned class with Jackson Hole Fire/EMS.","asOf":"2026-08-27T00:00:00.000Z","object":{"kind":"guide","id":"covering-vs-assembly","title":"Covering versus assembly","url":"/guides/covering-vs-assembly/"},"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-27T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"id":"guide:gutters-and-debris:17","anchor":"local-us-wy-teton-gutters-and-debris-17","place":"Unincorporated Teton County 2024 IWUIC gutters","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"The 2024 Teton County Fire Code Resolution adopts the 2024 IWUIC on unincorporated county lands, and its reviewed crosswalk keeps noncombustible gutters and downspouts under 504.4, 505.4, and 506.4 for IR1, IR2, and IR3. The normalized atom does not establish a debris-prevention device. Fire/EMS still returns Does Not Apply, IR3, IR2, or IR1 after project review; private-land map status, project, and official confirmation remain separate checks.","asOf":"2026-08-27T00:00:00.000Z","object":{"kind":"guide","id":"gutters-and-debris","title":"Gutters and debris as an ember bed","url":"/guides/gutters-and-debris/"},"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-27T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"id":"guide:how-wui-is-mapped:12","anchor":"local-us-wy-teton-how-wui-is-mapped-12","place":"Teton County 2024 IWUIC (local overlay)","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"Jackson Hole Fire/EMS says private land parcels in the Town and Teton County are within the mapped WUI and links the official GIS tool. For the County answer, the legal scope is unincorporated land. Fire/EMS separately reviews the project and returns Does Not Apply, IR3, IR2, or IR1. This site does not classify a parcel or assign that result.","asOf":"2026-08-27T00:00:00.000Z","object":{"kind":"guide","id":"how-wui-is-mapped","title":"How the WUI is mapped","url":"/guides/how-wui-is-mapped/"},"source":{"title":"WUI Information for Contractors","url":"https://www.tetoncountywy.gov/671/WUI-Information-for-Contractors","publisher":"Jackson Hole Fire/EMS","sourceType":"official","accessedOn":"2026-08-27T00:00:00.000Z"}},{"id":"standard:iwuic:27","anchor":"local-us-wy-teton-iwuic-27","place":"Unincorporated Teton County 2024 IWUIC","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"The County resolution adopts the 2024 IWUIC with Appendices A, C, D, E, and H only on unincorporated lands, effective 1 February 2025. Its Chapter 5 amendments do not change the 15 normalized material atoms. Confirm the official WUI map and project.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"standard","id":"iwuic","title":"International Wildland-Urban Interface Code","url":"/standards/iwuic/"},"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"id":"guide:mesh-vs-listed-vents:17","anchor":"local-us-wy-teton-mesh-vs-listed-vents-17","place":"Unincorporated Teton County 2024 IWUIC vent mesh","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"The 2024 Teton County Fire Code Resolution adopts the 2024 IWUIC on unincorporated county lands, and its reviewed crosswalk keeps the model prescriptive path of noncombustible corrosion-resistant mesh with openings no larger than 1/8 inch in IR1, IR2, and IR3. Fire/EMS still returns Does Not Apply, IR3, IR2, or IR1 after project review. Private-land map status, project, opening area, vent location, the local cold-roof exception, and official approval remain separate checks.","asOf":"2026-08-27T00:00:00.000Z","object":{"kind":"guide","id":"mesh-vs-listed-vents","title":"Mesh versus listed vents","url":"/guides/mesh-vs-listed-vents/"},"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-27T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}},{"id":"guide:wyoming-wui-code-status:2","anchor":"local-us-wy-teton-wyoming-wui-code-status-2","place":"Unincorporated Teton County 2024 IWUIC","placeId":"us-wy-teton","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"The County resolution adopts 2024 IWUIC with Appendices A, C, D, E, and H only on unincorporated lands. It was adopted 7 January 2025 and took effect 1 February 2025. The official WUI map and project facts remain checks.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"wyoming-wui-code-status","title":"Wyoming WUI code status","url":"/guides/wyoming-wui-code-status/"},"source":{"title":"2024 Teton County Fire Code Resolution","url":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","publisher":"Teton County, Wyoming","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2025-01-07T00:00:00.000Z"}}],"inherited":[{"id":"guide:covering-vs-assembly:26","anchor":"local-us-wy-covering-vs-assembly-26","place":"Wyoming statewide (IBC/IFC, no IWUIC)","placeId":"us-wy","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"Council on Fire Prevention Chapter 1 Section 2 does not incorporate IWUIC. There is no statewide IWUIC Class A roof. A county overlay may still exist.","asOf":"2026-08-24T00:00:00.000Z","object":{"kind":"guide","id":"covering-vs-assembly","title":"Covering versus assembly","url":"/guides/covering-vs-assembly/"},"source":{"title":"Wyoming Council on Fire Prevention Chapter 1 General Provisions","url":"https://rules.wyo.gov/DownloadFile.aspx?source_id=24233&source_type_id=81&doc_type_id=110&include_meta_data=Y&file_type=pdf&filename=24233.pdf&token=043077015103217169153143008234015069199230172011","publisher":"Wyoming Department of Fire Prevention and Electrical Safety","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2024-06-26T00:00:00.000Z"}},{"id":"guide:ibhs-does-not-replace-code:5","anchor":"local-us-ibhs-does-not-replace-code-5","place":"United States (IBHS program availability)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"IBHS’s About page, opened 26 August 2026, lists Wildfire Prepared Home as currently available in Arizona, California, Colorado, Florida, Idaho, Montana, Nevada, New Mexico, Oklahoma, Oregon, Texas, Utah, Washington, and Wyoming. The applicant must be the property owner. Application fee $125 nonrefundable. Designation valid three years with two annual photo reviews. The evaluator documents conditions and does not provide mitigation advice or determine qualification. Homes under active construction are not eligible. Share the certificate with the agent to get ready for that conversation; this page does not quote a premium percentage.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"ibhs-does-not-replace-code","title":"IBHS does not replace adopted code","url":"/guides/ibhs-does-not-replace-code/"},"source":{"title":"About Wildfire Prepared Home","url":"https://wildfireprepared.org/about/","publisher":"Insurance Institute for Business & Home Safety","sourceType":"standard-body","accessedOn":"2026-08-26T00:00:00.000Z"}},{"id":"standard:iwuic:26","anchor":"local-us-wy-iwuic-26","place":"Wyoming statewide (IBC/IFC, no IWUIC)","placeId":"us-wy","scopeKind":"place","scopeMode":"descendants","scopeRef":"iwuic","claim":"Council on Fire Prevention Chapter 1 Section 2 incorporates 2024 IBC, IEBC, IFC, IMC, and IFGC. IWUIC is not on that list. A county may still adopt IWUIC locally.","asOf":"2026-08-24T00:00:00.000Z","object":{"kind":"standard","id":"iwuic","title":"International Wildland-Urban Interface Code","url":"/standards/iwuic/"},"source":{"title":"Wyoming Council on Fire Prevention Chapter 1 General Provisions","url":"https://rules.wyo.gov/DownloadFile.aspx?source_id=24233&source_type_id=81&doc_type_id=110&include_meta_data=Y&file_type=pdf&filename=24233.pdf&token=043077015103217169153143008234015069199230172011","publisher":"Wyoming Department of Fire Prevention and Electrical Safety","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2024-06-26T00:00:00.000Z"}},{"id":"guide:no-national-wui-construction-code:1","anchor":"local-us-no-national-wui-construction-code-1","place":"United States (no federal WUI house code)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"Executive Order 13728 (18 May 2016) aims to mitigate wildfire risk to Federal buildings in the WUI. USFA’s implementation guidelines, opened 26 August 2026, say new Federal buildings and alterations greater than 5,000 square feet on Federal land in moderate or greater WUI risk should apply the current IWUIC or an equivalent nationally recognized code. The guidelines are advisory and create no homeowner permit. A private house is under the construction book the state or city adopted, if any.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"no-national-wui-construction-code","title":"No national WUI construction code","url":"/guides/no-national-wui-construction-code/"},"source":{"title":"Implementation Guidelines for Executive Order 13728 Wildland-Urban Interface Federal Risk Management","url":"https://www.usfa.fema.gov/downloads/pdf/eo13728_guidelines.pdf","publisher":"U.S. Fire Administration / Mitigation Framework Leadership Group","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2016-05-18T00:00:00.000Z"}},{"id":"guide:ready-gov-wildfire-and-the-house:1","anchor":"local-us-ready-gov-wildfire-and-the-house-1","place":"United States (Ready.gov household wildfire page)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"Ready.gov Wildfires, last updated 11 August 2026, tells households to use fire-resistant materials to build, renovate, or repair; find an outdoor water source with a hose that can reach any area of the property; and create a fire-resistant zone free of leaves, debris, or flammable materials for at least 30 feet from the home. Designate a room that can be closed off from outside air and set up a portable air cleaner when smoky conditions exist. Download the FEMA app for National Weather Service alerts. Evacuate when authorities say so. This is household guidance, not adopted WUI construction code.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"ready-gov-wildfire-and-the-house","title":"Ready.gov wildfire and the house","url":"/guides/ready-gov-wildfire-and-the-house/"},"source":{"title":"Wildfires","url":"https://www.ready.gov/wildfires","publisher":"Ready.gov / U.S. Department of Homeland Security","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"id":"guide:usfa-home-ignition-zones:1","anchor":"local-us-usfa-home-ignition-zones-1","place":"United States (USFA three home-ignition zones)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"USFA’s 16 December 2024 article says residents can change wildfire outcomes with simple, often low-cost work on the home and landscape. Immediate zone is the home and 0 to 5 feet: clean roofs and gutters, repair missing shingles or tiles, move mulch, flammable plants, leaves, needles, and firewood off exterior walls. Intermediate is 5 to 30 feet: mow lawns and native grasses to four inches, remove ladder fuels, prune trees 6 to 10 feet from the ground. Extended is 30 to 100 feet: clean ground litter, remove dead plants and trees, clear plants and trees from around sheds and out-buildings.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"usfa-home-ignition-zones","title":"USFA home ignition zones","url":"/guides/usfa-home-ignition-zones/"},"source":{"title":"Doing the Little Things Makes a Difference in Wildfire Safety","url":"https://www.usfa.fema.gov/blog/doing-the-little-things-makes-a-difference-in-wildfire-safety/","publisher":"U.S. Fire Administration","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z","documentDate":"2024-12-16T00:00:00.000Z"}},{"id":"guide:wind-sage-and-planting-where-nothing-stays-wet:2","anchor":"local-us-wy-wind-sage-and-planting-where-nothing-stays-wet-2","place":"UW Extension Barnyards and Backyards Spring 2005","placeId":"us-wy","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"All vegetation is potential fuel for fire. There are no truly fireproof plants. All will burn if the conditions are right. Fire-prone traits: needle-like or other fine leaves; resinous, oily, or waxy foliage or wood; loose or papery bark. Examples: most conifers, common juniper, Rocky Mountain juniper. Fire-resistant traits: little or no seasonal accumulation of dead leaves; non-resinous wood; high moisture content in leaves. Examples: cottonwood, aspens, roses, ashes, lilacs, chokecherry, littleleaf sumac, red-osier dogwood. Design with fire-resistant plants and noncombustible hardscape. For additional Firewise Wyoming information, reference Protect Your Home From Wildfire created for the Natrona County Project.","asOf":"2026-08-25T00:00:00.000Z","object":{"kind":"guide","id":"wind-sage-and-planting-where-nothing-stays-wet","title":"Wind, sage, and planting where nothing stays wet","url":"/guides/wind-sage-and-planting-where-nothing-stays-wet/"},"source":{"title":"Firewise Landscaping (Barnyards and Backyards, Spring 2005)","url":"https://www.uwyo.edu/barnbackyard/_files/documents/magazine/2005/spring/firewise-spring-barnyards-2005.pdf","publisher":"University of Wyoming Extension","sourceType":"official","accessedOn":"2026-08-25T00:00:00.000Z","documentDate":"2005-04-01T00:00:00.000Z"}},{"id":"guide:usfa-wui-is-not-only-the-west:2","anchor":"local-us-usfa-wui-is-not-only-the-west-2","place":"United States (NASF FY2021 Communities At Risk)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"NASF’s FY2021 Communities At Risk report counts 63,661 CAR nationwide. 19,268 (30.3%) were covered by a CWPP or equivalent. 3,267 (5.1%) met NASF’s reduced-risk test (Firewise-or-equivalent, a mitigation ordinance, or high-priority fuels work in a CWPP). By NASF region that year the CAR counts were Northeast-Midwest 10,826, South 43,771, and West 9,064.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"usfa-wui-is-not-only-the-west","title":"WUI is not only the West","url":"/guides/usfa-wui-is-not-only-the-west/"},"source":{"title":"Communities At Risk, Fiscal Year 2021","url":"https://www.stateforesters.org/wp-content/uploads/2022/06/NASF-2021-Communities-At-Risk-Report.pdf","publisher":"National Association of State Foresters","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"id":"guide:usfa-wui-is-not-only-the-west:1","anchor":"local-us-usfa-wui-is-not-only-the-west-1","place":"United States (USFA WUI community count)","placeId":"us","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"USFA’s WUI page, opened 26 August 2026, states that WUI fires are not only a western-state problem and that more than 60,000 communities in the United States are at risk, citing a National Association of State Foresters PDF. The page names brush, grass, forest, and other outdoor fires as the calls fire departments already run.","asOf":"2026-08-26T00:00:00.000Z","object":{"kind":"guide","id":"usfa-wui-is-not-only-the-west","title":"WUI is not only the West","url":"/guides/usfa-wui-is-not-only-the-west/"},"source":{"title":"Wildfire and the Wildland Urban Interface (WUI)","url":"https://www.usfa.fema.gov/wui/","publisher":"U.S. Fire Administration","sourceType":"official","accessedOn":"2026-08-26T00:00:00.000Z"}},{"id":"guide:wyoming-wui-code-status:1","anchor":"local-us-wy-wyoming-wui-code-status-1","place":"Wyoming statewide (IBC/IFC, no IWUIC)","placeId":"us-wy","scopeKind":"place","scopeMode":"descendants","scopeRef":null,"claim":"Council on Fire Prevention Chapter 1 Section 2 incorporates 2024 IBC, IEBC, IFC with named appendices, IMC, and IFGC. IWUIC is not on that list. A county overlay may still exist. Confirm with the building official.","asOf":"2026-08-24T00:00:00.000Z","object":{"kind":"guide","id":"wyoming-wui-code-status","title":"Wyoming WUI code status","url":"/guides/wyoming-wui-code-status/"},"source":{"title":"Wyoming Council on Fire Prevention Chapter 1 General Provisions","url":"https://rules.wyo.gov/DownloadFile.aspx?source_id=24233&source_type_id=81&doc_type_id=110&include_meta_data=Y&file_type=pdf&filename=24233.pdf&token=043077015103217169153143008234015069199230172011","publisher":"Wyoming Department of Fire Prevention and Electrical Safety","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2024-06-26T00:00:00.000Z"}}],"elsewhereInState":[{"id":"guide:how-to-read-a-state-page:4","anchor":"local-us-wy-how-to-read-a-state-page-4","place":"Wyoming statewide (no IWUIC on the state list)","placeId":"us-wy","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"Wyoming's `none` label means the current statewide incorporated-code list names 2024 IBC, IEBC, IFC with selected appendices, IMC, and IFGC, but not IWUIC. It does not erase separate local 2024 IWUIC applications in Jackson and unincorporated Teton County. Read the state label and the local scope together.","asOf":"2026-08-24T00:00:00.000Z","object":{"kind":"guide","id":"how-to-read-a-state-page","title":"How to read a state page","url":"/guides/how-to-read-a-state-page/"},"source":{"title":"Wyoming Council on Fire Prevention Chapter 1 General Provisions","url":"https://rules.wyo.gov/DownloadFile.aspx?source_id=24233&source_type_id=81&doc_type_id=110&include_meta_data=Y&file_type=pdf&filename=24233.pdf&token=043077015103217169153143008234015069199230172011","publisher":"Wyoming Department of Fire Prevention and Electrical Safety","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2024-06-26T00:00:00.000Z"}},{"id":"guide:no-national-wui-construction-code:3","anchor":"local-us-wy-no-national-wui-construction-code-3","place":"Wyoming (state list does not include IWUIC)","placeId":"us-wy","scopeKind":"place","scopeMode":"exact","scopeRef":null,"claim":"Wyoming Council on Fire Prevention Chapter 1 Section 2 incorporates the 2024 IBC, IEBC, IFC with named appendices, IMC, and IFGC. IWUIC is not on that statewide list. The national model is therefore not a Wyoming residential permit by itself; a separate local adoption such as Jackson's or Teton County's must supply the authority and scope.","asOf":"2026-08-24T00:00:00.000Z","object":{"kind":"guide","id":"no-national-wui-construction-code","title":"No national WUI construction code","url":"/guides/no-national-wui-construction-code/"},"source":{"title":"Wyoming Council on Fire Prevention Chapter 1 General Provisions","url":"https://rules.wyo.gov/DownloadFile.aspx?source_id=24233&source_type_id=81&doc_type_id=110&include_meta_data=Y&file_type=pdf&filename=24233.pdf&token=043077015103217169153143008234015069199230172011","publisher":"Wyoming Department of Fire Prevention and Electrical Safety","sourceType":"official","accessedOn":"2026-08-24T00:00:00.000Z","documentDate":"2024-06-26T00:00:00.000Z"}}]},"placeFocusedGuides":[{"id":"no-national-wui-construction-code","title":"No national WUI construction code","url":"/guides/no-national-wui-construction-code/"},{"id":"ready-gov-wildfire-and-the-house","title":"Ready.gov wildfire and the house","url":"/guides/ready-gov-wildfire-and-the-house/"},{"id":"usfa-home-ignition-zones","title":"USFA home ignition zones","url":"/guides/usfa-home-ignition-zones/"},{"id":"wind-sage-and-planting-where-nothing-stays-wet","title":"Wind, sage, and planting where nothing stays wet","url":"/guides/wind-sage-and-planting-where-nothing-stays-wet/"},{"id":"usfa-wui-is-not-only-the-west","title":"WUI is not only the West","url":"/guides/usfa-wui-is-not-only-the-west/"},{"id":"wyoming-wui-code-status","title":"Wyoming WUI code status","url":"/guides/wyoming-wui-code-status/"}],"plants":{"grain":"state-plus-optional-zip-zone","state":"WY","total":350,"nativeDocumented":0,"invasiveOrNoxiousFlagged":75,"page":"/grow/wyoming/"},"page":"/places/wyoming/teton-county/"}