{"id":"infinity-single-hung-round-top-california-fire-glass","license":"CC-BY-4.0","data":{"name":"Infinity Single Hung Round Top — California Fire Glass option","summary":"A single-hung round-top replacement window option documented with two panes, one annealed and one tempered.","productKind":"prescriptive-product","brand":"infinity-by-marvin","categories":["windows"],"applications":["replacement-window"],"complianceStatus":"attribute-match","complianceReason":"limited-evidence","complianceAsOf":"2026-08-25T00:00:00.000Z","attributes":{"assemblyRole":"exterior-window","paneCount":2,"temperedPaneCount":1},"attributeSources":[{"title":"Infinity Single Hung Round Top windows","url":"https://www.infinitywindows.com/windows/single-hung-round-top","publisher":"Infinity by Marvin","sourceType":"manufacturer","accessedOn":"2026-08-24T00:00:00.000Z","attributes":["assemblyRole","paneCount","temperedPaneCount"]}],"attributeEvidence":[{"attribute":"assemblyRole","value":"exterior-window","source":{"title":"Infinity Single Hung Round Top windows","url":"https://www.infinitywindows.com/windows/single-hung-round-top","publisher":"Infinity by Marvin","accessedOn":"2026-08-24T00:00:00.000Z","sourceType":"manufacturer"},"evidenceOrigin":"legacy-migration","notes":"Migrated from legacy attributeSources; exact document location was not recorded."},{"attribute":"paneCount","value":2,"source":{"title":"Infinity Single Hung Round Top windows","url":"https://www.infinitywindows.com/windows/single-hung-round-top","publisher":"Infinity by Marvin","accessedOn":"2026-08-24T00:00:00.000Z","sourceType":"manufacturer"},"evidenceOrigin":"legacy-migration","notes":"Migrated from legacy attributeSources; exact document location was not recorded."},{"attribute":"temperedPaneCount","value":1,"source":{"title":"Infinity Single Hung Round Top windows","url":"https://www.infinitywindows.com/windows/single-hung-round-top","publisher":"Infinity by Marvin","accessedOn":"2026-08-24T00:00:00.000Z","sourceType":"manufacturer"},"evidenceOrigin":"legacy-migration","notes":"Migrated from legacy attributeSources; exact document location was not recorded."}],"matchesRequirements":["cwrc-2025-class-2-multilayered-glazing","cwuic-2025-exterior-glazing-tempered","iwuic-2018-class-1-2-multilayered-glazing","iwuic-2021-class-1-2-multilayered-glazing","iwuic-2024-austin-zone-a-multilayered-glazing","iwuic-2024-class-1-2-multilayered-glazing","orsc-r327-multilayered-glazing","utah-uwui-2006-class-1-2-multilayered-glazing","utah-uwui-2006-class-1-2-tempered-glazing"],"manufacturerUrl":"https://www.infinitywindows.com/windows/single-hung-round-top","warnings":["Order and verify the named California Fire Glass option; other glazing configurations are different.","The manufacturer states that Infinity windows are not fire-rated; frame, opening, labeling, and installation remain separate checks."],"sources":[{"title":"Infinity Single Hung Round Top windows","url":"https://www.infinitywindows.com/windows/single-hung-round-top","publisher":"Infinity by Marvin","sourceType":"manufacturer","accessedOn":"2026-08-24T00:00:00.000Z"}],"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-24T00:00:00.000Z","featured":false,"sponsored":false},"resolveAt":{"us-ak":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-al":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ar":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-flagstaff":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-prescott":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-prescott","title":"Prescott 2024 IWUIC application","placeId":"us-az-prescott","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","sourceUrl":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-05-12","map":{"status":"official-map-required-not-located","summary":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located."}},"notes":[{"kind":"product-evidence","text":"Documented attributes match IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Prescott 2024 IWUIC application: Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application"},{"kind":"info","text":"Local scope: This multilayered-glazing path applies only after the City assigns IR1 or IR2 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","shortName":"IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-az-sedona":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ca":{"verdict":"conditional","application":{"applicationId":"cwuic-2025-california","title":"California 2025 CWUIC mapped-area application","placeId":"us-ca","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","sourceUrl":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","unresolvedPredicates":["official-hazard-map","project-type","official-confirmation"],"effectiveOn":"2026-01-01","map":{"status":"linked-official-tool","summary":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","url":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"}},"notes":[{"kind":"product-evidence","text":"Documented attributes match California multipane + tempered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2; Tempered panes ≥ 1.","href":"/requirements/cwuic-2025-exterior-glazing-tempered/"},{"kind":"application","text":"California 2025 CWUIC mapped-area application: California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application"},{"kind":"info","text":"Local scope: This tempered multilayered-glazing path applies only after the official map, permit facts, local amendments, and enforcing agency place the new building within Chapter 5.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland"},{"kind":"info","text":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","href":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"cwuic-2025-exterior-glazing-tempered","shortName":"California multipane + tempered glazing","href":"/requirements/cwuic-2025-exterior-glazing-tempered/","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"},{"attribute":"temperedPaneCount","op":"gte","value":1,"actual":1,"state":"matched"}]}]},"us-co":{"verdict":"conditional","application":{"applicationId":"cwrc-2025-colorado","title":"Colorado 2025 CWRC local-adoption path","placeId":"us-co","geographicScope":"mapped-area","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","sourceUrl":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","unresolvedPredicates":["local-adoption","official-hazard-map","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Colorado CWRC multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/cwrc-2025-class-2-multilayered-glazing/"},{"kind":"application","text":"Colorado 2025 CWRC local-adoption path: Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","href":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"cwrc-2025-class-2-multilayered-glazing","shortName":"Colorado CWRC multilayered glazing","href":"/requirements/cwrc-2025-class-2-multilayered-glazing/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-ct":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-dc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-de":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-fl":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ga":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-hi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ia":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-boise":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-eagle":{"verdict":"conditional","application":{"applicationId":"iwuic-2018-eagle","title":"Eagle 2018 IWUIC overlay application","placeId":"us-id-eagle","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","sourceUrl":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"linked-official-tool","summary":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","url":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"}},"notes":[{"kind":"product-evidence","text":"Documented attributes match 2018 IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2018-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Eagle 2018 IWUIC overlay application: Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application"},{"kind":"info","text":"Local scope: The multilayered-glazing path applies only when the official Table 503.1 outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","href":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2018-class-1-2-multilayered-glazing","shortName":"2018 IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2018-class-1-2-multilayered-glazing/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-il":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-in":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ks":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ky":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-la":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ma":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-md":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-me":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mo":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ms":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ne":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nj":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm-santa-fe":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv-clark":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-clark-county","title":"Clark County 2024 IWUIC application","placeId":"us-nv-clark","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","sourceUrl":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-12-02","effectiveOn":"2026-01-01","map":{"status":"official-map-required-not-located","summary":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located."}},"notes":[{"kind":"product-evidence","text":"Documented attributes match IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Clark County 2024 IWUIC application: Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This multilayered-glazing path applies only when the County assigns IR1 or IR2 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","shortName":"IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-nv-washoe":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-washoe-county","title":"Washoe County 2024 IWUIC Chapter 5 application","placeId":"us-nv-washoe","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","sourceUrl":"https://www.washoecounty.gov/building/getting_started/building_codes.php","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-06-10","effectiveOn":"2025-07-01","map":{"status":"linked-official-tool","summary":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","url":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"}},"notes":[{"kind":"product-evidence","text":"Documented attributes match IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Washoe County 2024 IWUIC Chapter 5 application: Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application"},{"kind":"info","text":"Local scope: This multilayered-glazing path applies only after the County and fire district inputs route the project to IR1 or IR2 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","href":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","shortName":"IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-ny":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-oh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ok":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-or":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-ashland":{"verdict":"conditional","application":{"applicationId":"orsc-r327-ashland","title":"Ashland ORSC R327 adoption","placeId":"us-or-ashland","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","sourceUrl":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","unresolvedPredicates":["project-type","official-confirmation"],"adoptedOn":"2021-06-01","effectiveOn":"2021-10-01"},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Ashland ORSC R327 adoption: Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","href":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption"},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-bend":{"verdict":"conditional","application":{"applicationId":"orsc-r327-bend","title":"Bend ORSC R327 application","placeId":"us-or-bend","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","sourceUrl":"https://bend.municipal.codes/BC/9.10.010","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-04-15"},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Bend ORSC R327 application: Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","href":"https://bend.municipal.codes/BC/9.10.010","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-deschutes":{"verdict":"conditional","application":{"applicationId":"orsc-r327-deschutes","title":"Deschutes County ORSC R327 application","placeId":"us-or-deschutes","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","sourceUrl":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2026-01-28","effectiveOn":"2026-04-01"},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Deschutes County ORSC R327 application: Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","href":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-grants-pass":{"verdict":"conditional","application":{"applicationId":"orsc-r327-grants-pass","title":"Grants Pass ORSC R327 adoption","placeId":"us-or-grants-pass","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","sourceUrl":"https://www.grantspassoregon.gov/DocumentCenter/View/42","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-06-02"},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Grants Pass ORSC R327 adoption: Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","href":"https://www.grantspassoregon.gov/DocumentCenter/View/42","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-lincoln":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-marion":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-medford":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-portland":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-redmond":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-sisters":{"verdict":"conditional","application":{"applicationId":"orsc-r327-sisters","title":"Sisters ORSC R327 application","placeId":"us-or-sisters","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","sourceUrl":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2025-11-19","effectiveOn":"2026-04-01"},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Sisters ORSC R327 application: Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","href":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-or-yamhill":{"verdict":"conditional","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"product-evidence","text":"Documented attributes match Oregon R327 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/orsc-r327-multilayered-glazing/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-multilayered-glazing","shortName":"Oregon R327 multilayered glazing","href":"/requirements/orsc-r327-multilayered-glazing/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-pa":{"verdict":"conditional","application":{"applicationId":"iwuic-2021-pennsylvania","title":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","placeId":"us-pa","geographicScope":"statewide","status":"active","requirementCoverage":"partial","scopeSummary":"34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","sourceUrl":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","unresolvedPredicates":["official-hazard-map","official-hazard-class","project-type","official-confirmation"],"effectiveOn":"2026-01-01"},"notes":[{"kind":"product-evidence","text":"Documented attributes match 2021 IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2021-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021: 34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021"},{"kind":"info","text":"Local scope: This glazing path applies only after official review assigns Class 1 or Class 2 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2021-class-1-2-multilayered-glazing","shortName":"2021 IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2021-class-1-2-multilayered-glazing/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-ri":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx-austin":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-austin","title":"Austin 2024 IWUIC proximity-zone application","placeId":"us-tx-austin","geographicScope":"authority-area","status":"active","requirementCoverage":"complete","scopeSummary":"Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","sourceUrl":"https://services.austintexas.gov/edims/document.cfm?id=451971","unresolvedPredicates":["official-boundary","official-hazard-map","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-04-10","effectiveOn":"2025-07-10","map":{"status":"linked-official-tool","summary":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","url":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"}},"notes":[{"kind":"product-evidence","text":"Documented attributes match Austin Zone A multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-austin-zone-a-multilayered-glazing/"},{"kind":"application","text":"Austin 2024 IWUIC proximity-zone application: Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application"},{"kind":"info","text":"Local scope: Zone A retains the broad exterior-opening multilayered-glazing path in Section 504.8.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","href":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-austin-zone-a-multilayered-glazing","shortName":"Austin Zone A multilayered glazing","href":"/requirements/iwuic-2024-austin-zone-a-multilayered-glazing/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-ut":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ut-salt-lake-city":{"verdict":"conditional","application":{"applicationId":"utah-uwui-2006-salt-lake-city","title":"Salt Lake City 2006 Utah UWUI application","placeId":"us-ut-salt-lake-city","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","sourceUrl":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"official-map-required-not-located","summary":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion."}},"notes":[{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 20-minute glazing: Assembly role is one of exterior window, glazed door, skylight.","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 20-minute glazing: Fire resistance ≥ 20 min.","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/"},{"kind":"product-evidence","text":"Documented attributes match 2006 Utah UWUI Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/utah-uwui-2006-class-1-2-multilayered-glazing/"},{"kind":"product-evidence","text":"Documented attributes match 2006 Utah UWUI Class 1–2 tempered glazing: Assembly role is one of exterior window, glazed door, skylight; Tempered panes ≥ 1.","href":"/requirements/utah-uwui-2006-class-1-2-tempered-glazing/"},{"kind":"application","text":"Salt Lake City 2006 Utah UWUI application: Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: Tempered glass is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: Multilayered glazing is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: A 20-minute fire-protection rating is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-2-20-minute-exterior-glazing","shortName":"2006 Utah UWUI Class 1–2 20-minute glazing","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"fireResistanceMinutes","op":"gte","value":20,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-1-2-multilayered-glazing","shortName":"2006 Utah UWUI Class 1–2 multilayered glazing","href":"/requirements/utah-uwui-2006-class-1-2-multilayered-glazing/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]},{"requirementId":"utah-uwui-2006-class-1-2-tempered-glazing","shortName":"2006 Utah UWUI Class 1–2 tempered glazing","href":"/requirements/utah-uwui-2006-class-1-2-tempered-glazing/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"temperedPaneCount","op":"gte","value":1,"actual":1,"state":"matched"}]}]},"us-ut-taylorsville":{"verdict":"conditional","application":{"applicationId":"utah-uwui-2006-taylorsville","title":"Taylorsville 2006 Utah UWUI application","placeId":"us-ut-taylorsville","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","sourceUrl":"https://www.utah.gov/pmn/files/1368799.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","official-confirmation"],"adoptedOn":"2025-12-17","effectiveOn":"2025-12-18","map":{"status":"linked-official-tool","summary":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","url":"https://www.utah.gov/pmn/files/1368799.pdf"}},"notes":[{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 20-minute glazing: Assembly role is one of exterior window, glazed door, skylight.","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 20-minute glazing: Fire resistance ≥ 20 min.","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/"},{"kind":"product-evidence","text":"Documented attributes match 2006 Utah UWUI Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/utah-uwui-2006-class-1-2-multilayered-glazing/"},{"kind":"product-evidence","text":"Documented attributes match 2006 Utah UWUI Class 1–2 tempered glazing: Assembly role is one of exterior window, glazed door, skylight; Tempered panes ≥ 1.","href":"/requirements/utah-uwui-2006-class-1-2-tempered-glazing/"},{"kind":"application","text":"Taylorsville 2006 Utah UWUI application: Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","href":"https://www.utah.gov/pmn/files/1368799.pdf","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: Tempered glass is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: Multilayered glazing is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: A 20-minute fire-protection rating is one exterior-glazing alternative when the official outcome includes IR1 or IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-2-20-minute-exterior-glazing","shortName":"2006 Utah UWUI Class 1–2 20-minute glazing","href":"/requirements/utah-uwui-2006-class-1-2-20-minute-exterior-glazing/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"fireResistanceMinutes","op":"gte","value":20,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-1-2-multilayered-glazing","shortName":"2006 Utah UWUI Class 1–2 multilayered glazing","href":"/requirements/utah-uwui-2006-class-1-2-multilayered-glazing/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]},{"requirementId":"utah-uwui-2006-class-1-2-tempered-glazing","shortName":"2006 Utah UWUI Class 1–2 tempered glazing","href":"/requirements/utah-uwui-2006-class-1-2-tempered-glazing/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"temperedPaneCount","op":"gte","value":1,"actual":1,"state":"matched"}]}]},"us-va":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-vt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa-kittitas":{"verdict":"unknown","application":{"applicationId":"kcc-wui-roof-kittitas-county","title":"Kittitas County WUI and locally printed construction application","placeId":"us-wa-kittitas","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","sourceUrl":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","unresolvedPredicates":["official-boundary","fire-department-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-03-02","map":{"status":"declared-authority-wide","summary":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"application","text":"Kittitas County WUI and locally printed construction application: Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application"},{"kind":"info","text":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm whether the site is outside a fire department boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[]},"us-wi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy-jackson":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-town-of-jackson","title":"Town of Jackson 2024 IWUIC application","placeId":"us-wy-jackson","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","unresolvedPredicates":["official-boundary","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2024-12-16","effectiveOn":"2025-01-01","map":{"status":"declared-authority-wide","summary":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review."}},"notes":[{"kind":"product-evidence","text":"Documented attributes match IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Town of Jackson 2024 IWUIC application: The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application"},{"kind":"info","text":"Local scope: This multilayered-glazing path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","shortName":"IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]},"us-wy-teton":{"verdict":"conditional","application":{"applicationId":"iwuic-2024-teton-county","title":"Unincorporated Teton County 2024 IWUIC application","placeId":"us-wy-teton","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-01-07","effectiveOn":"2025-02-01","map":{"status":"linked-official-tool","summary":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","url":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"}},"notes":[{"kind":"product-evidence","text":"Documented attributes match IWUIC Class 1–2 multilayered glazing: Assembly role is one of exterior window, glazed door, skylight; Glazing panes ≥ 2.","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/"},{"kind":"application","text":"Unincorporated Teton County 2024 IWUIC application: Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This multilayered-glazing path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","href":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-multilayered-glazing","shortName":"IWUIC Class 1–2 multilayered glazing","href":"/requirements/iwuic-2024-class-1-2-multilayered-glazing/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"matched","constraints":[{"attribute":"assemblyRole","op":"in","value":["exterior-window","glazed-door","skylight"],"actual":"exterior-window","state":"matched"},{"attribute":"paneCount","op":"gte","value":2,"actual":2,"state":"matched"}]}]}}}