{"id":"avm-industries-inc-forevercoat-100-walking-deck-system","license":"CC-BY-4.0","data":{"name":"Forevercoat 100 Walking Deck System","summary":"AVM Industries, Inc. listing 8110-2336:0501 in OSFM category 8110. Forevercoat 100 Walking Deck System. Product consists of a waterproofing system with a cementitious wear surface installed over polymer modified concrete covering 2.5 lbs./sq. yd. of galvanized metal lath installed over a minimum 5/8\" plywood substrate. Refer to manufacturer's installation instructions and product data sheets.","productKind":"listed-assembly","brand":"avm-industries-inc","categories":["decking"],"listings":[{"program":"CAL FIRE BML","listingId":"8110-2336:0501","status":"listed","url":"https://calfire.govmotus.org/BMLSearch/Index","dated":"2026-08-25T00:00:00.000Z","issued":"2026-05-31T00:00:00.000Z","expires":"2027-06-30T00:00:00.000Z","notes":"From 2025 OSFM WUI Listed Products Handbook (2025-09-02). Category 8110. SFM 12-7A-4A; Class A Flame Spread Live BML 2026-08-25: expires 2027-06-30."},{"program":"ICC-ES","listingId":"ESR-2125","status":"listed","url":"https://icc-es.org/report-listing/esr-2125/","dated":"2026-08-24T00:00:00.000Z","notes":"Report holder and product name matched the public ICC-ES California supplement directory on 2026-08-24. Open the report for scope and conditions."}],"complianceStatus":"listed","complianceReason":"consensus","complianceAsOf":"2026-08-25T00:00:00.000Z","attributes":{"assemblyRole":"deck-surface"},"attributeEvidence":[{"attribute":"assemblyRole","value":"deck-surface","source":{"title":"CAL FIRE OSFM Building Materials Listing — 8110-2336:0501","url":"https://calfire.govmotus.org/BMLSearch/Index","publisher":"CAL FIRE OSFM","accessedOn":"2026-08-26T00:00:00.000Z","sourceType":"official-listing"},"documentLocation":"Listing 8110-2336:0501, Description field","excerpt":"Forevercoat 100 Walking Deck System.","notes":"Reviewed normalization: deck-board-or-walking-deck-means-surface."}],"standards":["sfm-12-7a-4","cal-fire-bml","icc-es"],"warnings":["Listing is from the OSFM WUI handbook. Confirm the live GOVmotus record and the exact model before specification.","OSFM listing is not a permit. The authority having jurisdiction decides."],"sources":[{"title":"2025 OSFM WUI Listed Products Handbook (2 September 2025)","url":"https://osfm.fire.ca.gov/what-we-do/fire-engineering-and-investigations/building-materials-listing","publisher":"CAL FIRE OSFM","sourceType":"official","accessedOn":"2026-08-23T00:00:00.000Z","documentDate":"2025-09-02T00:00:00.000Z"},{"title":"OSFM Building Materials Listing search","url":"https://calfire.govmotus.org/BMLSearch/Index","publisher":"CAL FIRE OSFM","sourceType":"listing-body","accessedOn":"2026-08-23T00:00:00.000Z"},{"title":"ICC-ES ESR-2125 directory record","url":"https://icc-es.org/report-listing/esr-2125/","publisher":"ICC Evaluation Service","sourceType":"listing-body","accessedOn":"2026-08-24T00:00:00.000Z"}],"author":"grayson-graham","reviewStatus":"draft","lastVerified":"2026-08-26T00:00:00.000Z","featured":false,"sponsored":false},"resolveAt":{"us-ak":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-al":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ar":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-flagstaff":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-az-prescott":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-prescott","title":"Prescott 2024 IWUIC application","placeId":"us-az-prescott","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","sourceUrl":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-05-12","map":{"status":"official-map-required-not-located","summary":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Prescott 2024 IWUIC application: Prescott declares its entire incorporated city boundary a WUI, applies its amended 2024 IWUIC there, and uses City predictive modeling and GIS to assign extreme/IR1, high/IR2, or moderate/IR3 construction; boundary, project, risk-class, effective-date, and official checks remain open.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application"},{"kind":"info","text":"Local scope: This noncombustible appendage path applies only after the City assigns IR1 or IR2 construction.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"info","text":"Section 302.1 declares the entire city WUI, but Sections 302.2 and 502 require the City's public GIS and predictive model to assign the parcel's risk severity; the exact current public risk-layer URL was not located.","href":"https://www.codepublishing.com/AZ/Prescott/html/Prescott06/Prescott062.html"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","shortName":"IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/","applicationId":"iwuic-2024-prescott","applicationTitle":"Prescott 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-az-sedona":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ca":{"verdict":"conditional","application":{"applicationId":"cwuic-2025-california","title":"California 2025 CWUIC mapped-area application","placeId":"us-ca","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","sourceUrl":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","unresolvedPredicates":["official-hazard-map","project-type","official-confirmation"],"effectiveOn":"2026-01-01","map":{"status":"linked-official-tool","summary":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","url":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"}},"notes":[{"kind":"product-evidence","text":"Current CAL FIRE BML listing evidence is recorded. Match the model and orientation.","href":"/materials/avm-industries-inc-forevercoat-100-walking-deck-system/"},{"kind":"application","text":"California 2025 CWUIC mapped-area application: California applies 2025 CWUIC Chapter 5 to new buildings in mapped State Responsibility Area fire-hazard zones and in locally designated High and Very High zones; the official map, permit facts, any local amendment, and the enforcing agency still govern a project.","href":"https://osfm.fire.ca.gov/what-we-do/community-wildfire-preparedness-and-mitigation/building-in-the-wildland","applicationId":"cwuic-2025-california","applicationTitle":"California 2025 CWUIC mapped-area application"},{"kind":"info","text":"CAL FIRE's official statewide viewer accepts an address and displays State and Local Responsibility Area fire-hazard zones; the local jurisdiction remains the source for an adopted Local Responsibility Area designation and project decision.","href":"https://experience.arcgis.com/experience/5065c998b4b0462f9ec3c6c226c610a9"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[]},"us-co":{"verdict":"unknown","application":{"applicationId":"cwrc-2025-colorado","title":"Colorado 2025 CWRC local-adoption path","placeId":"us-co","geographicScope":"mapped-area","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","sourceUrl":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","unresolvedPredicates":["local-adoption","official-hazard-map","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for Colorado CWRC Class A deck surface: Assembly role = deck surface.","href":"/requirements/cwrc-2025-class-2-class-a-deck-surface/"},{"kind":"check","text":"Still undocumented for Colorado CWRC Class A deck surface: Fire rating = class a.","href":"/requirements/cwrc-2025-class-2-class-a-deck-surface/"},{"kind":"info","text":"Documented for Colorado CWRC noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/cwrc-2025-class-2-noncombustible-deck-surface/"},{"kind":"check","text":"Still undocumented for Colorado CWRC noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/cwrc-2025-class-2-noncombustible-deck-surface/"},{"kind":"application","text":"Colorado 2025 CWRC local-adoption path: Colorado has published the 2025 Wildfire Resiliency Code for adoption by named jurisdictions; the local ordinance, official hazard map, and project class determine whether a requirement reaches a project.","href":"https://dfpc.colorado.gov/colorado-wildfire-resiliency-code","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"cwrc-2025-class-2-class-a-deck-surface","shortName":"Colorado CWRC Class A deck surface","href":"/requirements/cwrc-2025-class-2-class-a-deck-surface/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"fireRating","op":"eq","value":"class-a","state":"undocumented"}]},{"requirementId":"cwrc-2025-class-2-noncombustible-deck-surface","shortName":"Colorado CWRC noncombustible deck surface","href":"/requirements/cwrc-2025-class-2-noncombustible-deck-surface/","applicationId":"cwrc-2025-colorado","applicationTitle":"Colorado 2025 CWRC local-adoption path","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-ct":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-dc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-de":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-fl":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ga":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-hi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ia":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-boise":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-id-eagle":{"verdict":"unknown","application":{"applicationId":"iwuic-2018-eagle","title":"Eagle 2018 IWUIC overlay application","placeId":"us-id-eagle","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","sourceUrl":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"linked-official-tool","summary":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","url":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for 2018 IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2018-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for 2018 IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2018-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Eagle 2018 IWUIC overlay application: Eagle applies its locally amended 2018 IWUIC inside the Ordinance 947 overlay to named project classes, subject to the official mapped boundary, the full Table 503.1 outcome, the City-approved Fire Protection Plan exemption, project exceptions, effective-date, and code-official determinations. The 15 joined rows are a conservative subset of product-field paths for IR1, IR2, and IR3; they do not project Table 503.1's IR1 + N.C., Not Required, or Not Permitted outcomes.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application"},{"kind":"info","text":"Local scope: The noncombustible appendage path applies only when the official Table 503.1 outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/eagleid/latest/eagle_id/0-0-0-16712"},{"kind":"info","text":"Eagle publishes the Ordinance 947 WUI Overlay District Map as the controlling mapped-area starting point; parcel inclusion and current boundary status remain official determinations.","href":"https://www.cityofeagle.org/DocumentCenter/View/13203/WUI-Overlay-District-Map---Ord-947-11-x-17"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2018-class-1-2-noncombustible-deck","shortName":"2018 IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2018-class-1-2-noncombustible-deck/","applicationId":"iwuic-2018-eagle","applicationTitle":"Eagle 2018 IWUIC overlay application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-il":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-in":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ks":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ky":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-la":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ma":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-md":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-me":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mo":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ms":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-mt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ne":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nj":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nm-santa-fe":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-nv-clark":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-clark-county","title":"Clark County 2024 IWUIC application","placeId":"us-nv-clark","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","sourceUrl":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-12-02","effectiveOn":"2026-01-01","map":{"status":"official-map-required-not-located","summary":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Clark County 2024 IWUIC application: Clark County applies its 2024 IWUIC through the County Fire Department's unincorporated service jurisdiction; official boundary, WUI map, assigned IR class, project, and code-official checks remain open.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This noncombustible appendage path applies only when the County assigns IR1 or IR2 construction.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"info","text":"Ordinance 5320 requires public or electronic WUI mapping unless the community risk assessment identifies no WUI; no current official map URL or project-specific IR-class answer was located.","href":"https://weddings.vegas/wp-content/uploads/2026/02/ORD-5320.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","shortName":"IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/","applicationId":"iwuic-2024-clark-county","applicationTitle":"Clark County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-nv-washoe":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-washoe-county","title":"Washoe County 2024 IWUIC Chapter 5 application","placeId":"us-nv-washoe","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","sourceUrl":"https://www.washoecounty.gov/building/getting_started/building_codes.php","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-06-10","effectiveOn":"2025-07-01","map":{"status":"linked-official-tool","summary":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","url":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Washoe County 2024 IWUIC Chapter 5 application: Washoe County's Building Program applies 2024 IWUIC Chapter 5 under Ordinance 1736, while the companion Chapter 60 fire-code adoption supplies the fire-authority inputs in Truckee Meadows Fire Protection District and other unincorporated areas where the County has fire responsibility; boundary, parcel hazard, water, defensible space, assigned IR class, project, transition date, and official checks remain open.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application"},{"kind":"info","text":"Local scope: This noncombustible appendage path applies only after the County and fire district inputs route the project to IR1 or IR2 construction.","href":"https://www.washoecounty.gov/building/getting_started/building_codes.php"},{"kind":"info","text":"Washoe's official EZ Fire-WUI map accepts an address or APN and returns the parcel hazard category; the applicable fire district must separately confirm water and defensible-space conformity before Table 503.1 yields an IR class.","href":"https://gis.washoecounty.us/wrms/quick/firehazard?auth=0"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","shortName":"IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/","applicationId":"iwuic-2024-washoe-county","applicationTitle":"Washoe County 2024 IWUIC Chapter 5 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-ny":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-oh":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ok":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-or":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-ashland":{"verdict":"unknown","application":{"applicationId":"orsc-r327-ashland","title":"Ashland ORSC R327 adoption","placeId":"us-or-ashland","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","sourceUrl":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","unresolvedPredicates":["project-type","official-confirmation"],"adoptedOn":"2021-06-01","effectiveOn":"2021-10-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Ashland ORSC R327 adoption: Ashland Ordinance 3198 adopts the current ORSC including R327.4 within the City of Ashland, effective 1 October 2021. The City states its Wildfire Hazard Zone covers all city parcels; the codified text retains a written substantial-compliance waiver by the Building Official. Confirm the project path with the City.","href":"https://records.ashland.or.us/weblink/0/edoc/129893/Ord%203198.pdf","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption"},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-ashland","applicationTitle":"Ashland ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-bend":{"verdict":"unknown","application":{"applicationId":"orsc-r327-bend","title":"Bend ORSC R327 application","placeId":"us-or-bend","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","sourceUrl":"https://bend.municipal.codes/BC/9.10.010","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2026-04-15"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Bend ORSC R327 application: Current Bend Code 9.10.010 establishes the entire area within Bend city limits as the WUI Hazard Zone and applies ORSC R327 throughout that area. Ordinance NS-2552 was adopted on 15 April 2026 and codified in May 2026, but the opened sources do not establish its exact effective date or decide the boundary and project trigger for a parcel. Confirm with Building Safety.","href":"https://bend.municipal.codes/BC/9.10.010","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-bend","applicationTitle":"Bend ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-deschutes":{"verdict":"unknown","application":{"applicationId":"orsc-r327-deschutes","title":"Deschutes County ORSC R327 application","placeId":"us-or-deschutes","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","sourceUrl":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2026-01-28","effectiveOn":"2026-04-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Deschutes County ORSC R327 application: Deschutes County states that ORSC R327 is mandatory throughout the unincorporated county for new ORSC dwellings and new accessory structures from 1 April 2026. The current County page excludes ordinary additions, repairs, remodels, manufactured dwellings, commercial-code buildings, and named small detached accessory structures. Confirm the parcel boundary, project classification, and permit determination.","href":"https://www.deschutescounty.gov/1255/Fire-Hardening-Requirements-R327","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-deschutes","applicationTitle":"Deschutes County ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-grants-pass":{"verdict":"unknown","application":{"applicationId":"orsc-r327-grants-pass","title":"Grants Pass ORSC R327 adoption","placeId":"us-or-grants-pass","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","sourceUrl":"https://www.grantspassoregon.gov/DocumentCenter/View/42","unresolvedPredicates":["official-boundary","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-06-02"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Grants Pass ORSC R327 adoption: Grants Pass Municipal Code 9.04.010 adopts the ORSC and Section R327 into the City Building Code, while 9.04.200 requires new construction to conform to that code. Oregon BCD describes locally adopted R327 as applying to new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones. Confirm the city boundary, hazard-zone and project trigger, effective date, and current permit path with Building Division.","href":"https://www.grantspassoregon.gov/DocumentCenter/View/42","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-grants-pass","applicationTitle":"Grants Pass ORSC R327 adoption","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-lincoln":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-marion":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-medford":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-portland":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-redmond":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-sisters":{"verdict":"unknown","application":{"applicationId":"orsc-r327-sisters","title":"Sisters ORSC R327 application","placeId":"us-or-sisters","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"partial","scopeSummary":"Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","sourceUrl":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","unresolvedPredicates":["official-boundary","project-type","official-confirmation"],"adoptedOn":"2025-11-19","effectiveOn":"2026-04-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Sisters ORSC R327 application: Sisters City Code 15.05.010 adopts ORSC R327 throughout the City and assigns administration to Deschutes County Building Safety. Current City and County permit pages state that it is mandatory for new ORSC dwellings and new accessory structures from 1 April 2026. Confirm the incorporated boundary, project classification, and permit determination.","href":"https://www.codepublishing.com/OR/Sisters/html/Sisters15/Sisters1505.html","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-sisters","applicationTitle":"Sisters ORSC R327 application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-or-yamhill":{"verdict":"unknown","application":{"applicationId":"orsc-r327-oregon-local-option","title":"Oregon R327 local-option framework","placeId":"us-or","geographicScope":"unknown","status":"available-for-local-adoption","requirementCoverage":"partial","scopeSummary":"Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","sourceUrl":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","unresolvedPredicates":["local-adoption","official-boundary","project-type","official-confirmation"]},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for ORSC R327 noncombustible deck surface: Assembly role = deck surface.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"check","text":"Still undocumented for ORSC R327 noncombustible deck surface: Noncombustible = Yes.","href":"/requirements/orsc-r327-noncombustible-walking-surface/"},{"kind":"application","text":"Oregon R327 local-option framework: Oregon makes ORSC Section R327 available for local adoption; this state record does not make the section a statewide WUI construction mandate.","href":"https://www.oregon.gov/bcd/codes-stand/pages/wildfire-hazard-mitigation.aspx","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework"},{"kind":"check","text":"Confirm local adoption."},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"orsc-r327-noncombustible-walking-surface","shortName":"ORSC R327 noncombustible deck surface","href":"/requirements/orsc-r327-noncombustible-walking-surface/","applicationId":"orsc-r327-oregon-local-option","applicationTitle":"Oregon R327 local-option framework","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"eq","value":"deck-surface","actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-pa":{"verdict":"unknown","application":{"applicationId":"iwuic-2021-pennsylvania","title":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","placeId":"us-pa","geographicScope":"statewide","status":"active","requirementCoverage":"partial","scopeSummary":"34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","sourceUrl":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","unresolvedPredicates":["official-hazard-map","official-hazard-class","project-type","official-confirmation"],"effectiveOn":"2026-01-01"},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for 2021 IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2021-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for 2021 IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2021-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021: 34 Pa. Code § 403.21(a)(11) adopts and incorporates by reference the International Wildland-Urban Interface Code of 2021 as part of the Uniform Construction Code. The November 7, 2025 amendment is effective January 1, 2026, and the State's final report says the 2021 IWUIC was adopted without modification. Whether a given lot is in a wildland-urban interface, which ignition-resistant class applies, and whether a given project type is in scope still depend on the official map and the building official.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021"},{"kind":"info","text":"Local scope: This appendage path applies only after official review assigns Class 1 or Class 2 construction.","href":"https://www.pacodeandbulletin.gov/secure/pacode/data/034/chapter403/s403.21.html"},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2021-class-1-2-noncombustible-deck","shortName":"2021 IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2021-class-1-2-noncombustible-deck/","applicationId":"iwuic-2021-pennsylvania","applicationTitle":"Pennsylvania Uniform Construction Code incorporates IWUIC 2021","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-ri":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sc":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-sd":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tn":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-tx-austin":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-austin","title":"Austin 2024 IWUIC proximity-zone application","placeId":"us-tx-austin","geographicScope":"authority-area","status":"active","requirementCoverage":"complete","scopeSummary":"Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","sourceUrl":"https://services.austintexas.gov/edims/document.cfm?id=451971","unresolvedPredicates":["official-boundary","official-hazard-map","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-04-10","effectiveOn":"2025-07-10","map":{"status":"linked-official-tool","summary":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","url":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for Austin Zone A noncombustible appendage: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-austin-zone-a-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for Austin Zone A noncombustible appendage: Noncombustible = Yes.","href":"/requirements/iwuic-2024-austin-zone-a-noncombustible-appendage/"},{"kind":"info","text":"Documented for Austin Zone B 30-foot appendage: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-austin-zone-b-30-foot-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for Austin Zone B 30-foot appendage: Noncombustible = Yes.","href":"/requirements/iwuic-2024-austin-zone-b-30-foot-noncombustible-appendage/"},{"kind":"info","text":"Documented for Austin Zone C 10-foot appendage: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-austin-zone-c-10-foot-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for Austin Zone C 10-foot appendage: Noncombustible = Yes.","href":"/requirements/iwuic-2024-austin-zone-c-10-foot-noncombustible-appendage/"},{"kind":"application","text":"Austin 2024 IWUIC proximity-zone application: Austin applies its amended 2024 IWUIC to submissions on or after July 10, 2025 in City full-purpose and limited-purpose areas, subject to transition, official WUI, proximity-zone, project, and mixed-jurisdiction determinations.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application"},{"kind":"info","text":"Local scope: Zone A covers attached appendages and detached unenclosed accessory structures without a distance predicate.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Local scope: Zone B reaches an unenclosed appendage or structure attached to or within 30 feet of habitable space.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Local scope: Zone C reaches an unenclosed appendage or structure attached to or within 10 feet of habitable space.","href":"https://services.austintexas.gov/edims/document.cfm?id=451971"},{"kind":"info","text":"Austin's official map is a starting point; onsite measurement and the code official determine WUI and proximity-zone results.","href":"https://austin.maps.arcgis.com/apps/instant/media/index.html?appid=0c0889a8bac34cf4a1ca6ce6777c3937"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-austin-zone-a-noncombustible-appendage","shortName":"Austin Zone A noncombustible appendage","href":"/requirements/iwuic-2024-austin-zone-a-noncombustible-appendage/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"iwuic-2024-austin-zone-b-30-foot-noncombustible-appendage","shortName":"Austin Zone B 30-foot appendage","href":"/requirements/iwuic-2024-austin-zone-b-30-foot-noncombustible-appendage/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"iwuic-2024-austin-zone-c-10-foot-noncombustible-appendage","shortName":"Austin Zone C 10-foot appendage","href":"/requirements/iwuic-2024-austin-zone-c-10-foot-noncombustible-appendage/","applicationId":"iwuic-2024-austin","applicationTitle":"Austin 2024 IWUIC proximity-zone application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-ut":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-ut-salt-lake-city":{"verdict":"unknown","application":{"applicationId":"utah-uwui-2006-salt-lake-city","title":"Salt Lake City 2006 Utah UWUI application","placeId":"us-ut-salt-lake-city","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","sourceUrl":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"map":{"status":"official-map-required-not-located","summary":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/"},{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 one-hour deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 one-hour deck: Fire resistance ≥ 60 min.","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/"},{"kind":"application","text":"Salt Lake City 2006 Utah UWUI application: Salt Lake City Code 18.44.010.B applies the Utah Wildland Urban Interface Code named by 15A-2-103 to property on the official City WUI map. The 22 joined rows are an edition-specific product-semantic subset; map inclusion, Table 503.1 outcome, project, effective date, and official confirmation remain required.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: The one-hour path applies to attached unenclosed accessory structures and projections such as decks when the official outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"Local scope: The noncombustible path applies to attached unenclosed accessory structures and projections such as decks when the official outcome includes IR1 or IR2 construction.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"info","text":"City Code requires the Salt Lake City Wildland Urban Interface Map to be kept by the City Recorder, but this review did not locate a current public official map URL. A ZIP does not establish inclusion.","href":"https://codelibrary.amlegal.com/codes/saltlakecityut/latest/saltlakecity_ut/0-0-0-60548"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-2-noncombustible-appendage","shortName":"2006 Utah UWUI Class 1–2 noncombustible deck","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-1-2-one-hour-appendage","shortName":"2006 Utah UWUI Class 1–2 one-hour deck","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/","applicationId":"utah-uwui-2006-salt-lake-city","applicationTitle":"Salt Lake City 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"fireResistanceMinutes","op":"gte","value":60,"state":"undocumented"}]}]},"us-ut-taylorsville":{"verdict":"unknown","application":{"applicationId":"utah-uwui-2006-taylorsville","title":"Taylorsville 2006 Utah UWUI application","placeId":"us-ut-taylorsville","geographicScope":"mapped-area","status":"active","requirementCoverage":"partial","scopeSummary":"Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","sourceUrl":"https://www.utah.gov/pmn/files/1368799.pdf","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","official-confirmation"],"adoptedOn":"2025-12-17","effectiveOn":"2025-12-18","map":{"status":"linked-official-tool","summary":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","url":"https://www.utah.gov/pmn/files/1368799.pdf"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/"},{"kind":"info","text":"Documented for 2006 Utah UWUI Class 1–2 one-hour deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/"},{"kind":"check","text":"Still undocumented for 2006 Utah UWUI Class 1–2 one-hour deck: Fire resistance ≥ 60 min.","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/"},{"kind":"application","text":"Taylorsville 2006 Utah UWUI application: Ordinance 25-15 adopts the Utah Wildland Urban Interface Code with FFSL-approved alternatives or amendments and its Exhibit A map. The 22 joined rows are an edition-specific product-semantic subset; mapped status, Table 503.1 outcome, project, and official confirmation remain required.","href":"https://www.utah.gov/pmn/files/1368799.pdf","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application"},{"kind":"info","text":"Local scope: The one-hour path applies to attached unenclosed accessory structures and projections such as decks when the official outcome includes IR1 or IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Local scope: The noncombustible path applies to attached unenclosed accessory structures and projections such as decks when the official outcome includes IR1 or IR2 construction.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"info","text":"Ordinance 25-15 adopts Exhibit A as the official map of high-risk WUI property and WUI property that is not high-risk. The linked official ordinance contains the exhibit; a ZIP does not establish mapped status or construction class.","href":"https://www.utah.gov/pmn/files/1368799.pdf"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"utah-uwui-2006-class-1-2-noncombustible-appendage","shortName":"2006 Utah UWUI Class 1–2 noncombustible deck","href":"/requirements/utah-uwui-2006-class-1-2-noncombustible-appendage/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"utah-uwui-2006-class-1-2-one-hour-appendage","shortName":"2006 Utah UWUI Class 1–2 one-hour deck","href":"/requirements/utah-uwui-2006-class-1-2-one-hour-appendage/","applicationId":"utah-uwui-2006-taylorsville","applicationTitle":"Taylorsville 2006 Utah UWUI application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"fireResistanceMinutes","op":"gte","value":60,"state":"undocumented"}]}]},"us-va":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-vt":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wa-kittitas":{"verdict":"unknown","application":{"applicationId":"kcc-wui-roof-kittitas-county","title":"Kittitas County WUI and locally printed construction application","placeId":"us-wa-kittitas","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"partial","scopeSummary":"Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","sourceUrl":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","unresolvedPredicates":["official-boundary","fire-department-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2021-03-02","map":{"status":"declared-authority-wide","summary":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for Kittitas IR1–IR2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/kcc-20-10-ir1-ir2-noncombustible-appendage/"},{"kind":"check","text":"Still undocumented for Kittitas IR1–IR2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/kcc-20-10-ir1-ir2-noncombustible-appendage/"},{"kind":"info","text":"Documented for Kittitas IR1–IR2 one-hour deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/kcc-20-10-ir1-ir2-one-hour-appendage/"},{"kind":"check","text":"Still undocumented for Kittitas IR1–IR2 one-hour deck: Fire resistance ≥ 60 min.","href":"/requirements/kcc-20-10-ir1-ir2-one-hour-appendage/"},{"kind":"application","text":"Kittitas County WUI and locally printed construction application: Kittitas County declares every unincorporated area WUI and applies its current local WUI amendments there; Chapter 14.12 separately sets Class C, B, or A roof-covering floors by hazard class, but its classification system limits the hazard-specific Class A and B paths to areas outside a fire department. Parcel jurisdiction, that fire-department boundary, the current hazard map and class, water and defensible-space inputs, project trigger, exact classified configuration, effective date, and official review remain open.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application"},{"kind":"info","text":"Local scope: Sections 504.7 and 505.7 apply this path to attached unenclosed accessory structures and projections such as decks after the official result is IR1 or IR2.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"info","text":"Local scope: Sections 504.7 and 505.7 apply this path to attached unenclosed accessory structures and projections such as decks after the official result is IR1 or IR2.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"info","text":"The current Fire Marshal page confirms that all unincorporated Kittitas County is WUI. Title 20 still requires the most-current County map and official water and defensible-space inputs before Table 503.1 yields the project result; this record does not attach the archived 2013 map as if it were current.","href":"https://www.co.kittitas.wa.us/boc/countycode/title20.aspx"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Confirm whether the site is outside a fire department boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"kcc-20-10-ir1-ir2-noncombustible-appendage","shortName":"Kittitas IR1–IR2 noncombustible deck","href":"/requirements/kcc-20-10-ir1-ir2-noncombustible-appendage/","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]},{"requirementId":"kcc-20-10-ir1-ir2-one-hour-appendage","shortName":"Kittitas IR1–IR2 one-hour deck","href":"/requirements/kcc-20-10-ir1-ir2-one-hour-appendage/","applicationId":"kcc-wui-roof-kittitas-county","applicationTitle":"Kittitas County WUI and locally printed construction application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"fireResistanceMinutes","op":"gte","value":60,"state":"undocumented"}]}]},"us-wi":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wv":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy":{"verdict":"unknown","application":null,"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."}],"requirementTraces":[]},"us-wy-jackson":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-town-of-jackson","title":"Town of Jackson 2024 IWUIC application","placeId":"us-wy-jackson","geographicScope":"incorporated-boundary","status":"active","requirementCoverage":"complete","scopeSummary":"The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","unresolvedPredicates":["official-boundary","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2024-12-16","effectiveOn":"2025-01-01","map":{"status":"declared-authority-wide","summary":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review."}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Town of Jackson 2024 IWUIC application: The Town of Jackson declares its entire corporate boundary, including later amendments, within the WUI; Fire/EMS still determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application"},{"kind":"info","text":"Local scope: This noncombustible appendage path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"info","text":"Ordinance 1416 declares the entire current Town boundary within the WUI, but Fire/EMS still assigns the project-specific IR3, IR2, IR1, or does-not-apply result after site-hazard review.","href":"https://www.tetoncountywy.gov/DocumentCenter/View/32222/TOJ-2024-Fire-Code-Current"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","shortName":"IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/","applicationId":"iwuic-2024-town-of-jackson","applicationTitle":"Town of Jackson 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]},"us-wy-teton":{"verdict":"unknown","application":{"applicationId":"iwuic-2024-teton-county","title":"Unincorporated Teton County 2024 IWUIC application","placeId":"us-wy-teton","geographicScope":"unincorporated-county","status":"active","requirementCoverage":"complete","scopeSummary":"Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","sourceUrl":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","unresolvedPredicates":["official-boundary","official-hazard-map","official-hazard-class","project-type","effective-date","official-confirmation"],"adoptedOn":"2025-01-07","effectiveOn":"2025-02-01","map":{"status":"linked-official-tool","summary":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","url":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"}},"notes":[{"kind":"unknown","text":"No sourced listing or documented attribute match joins this product to a code application here."},{"kind":"info","text":"Documented for IWUIC Class 1–2 noncombustible deck: Assembly role is one of deck structure, deck surface.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"check","text":"Still undocumented for IWUIC Class 1–2 noncombustible deck: Noncombustible = Yes.","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/"},{"kind":"application","text":"Unincorporated Teton County 2024 IWUIC application: Teton County applies its amended 2024 IWUIC only within unincorporated county lands; Fire/EMS separately determines whether IR construction applies and, if so, assigns IR3, IR2, or IR1 after its site-hazard review.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application"},{"kind":"info","text":"Local scope: This noncombustible appendage path applies only when Fire/EMS assigns IR1 or IR2 construction.","href":"https://tetoncountywy.gov/DocumentCenter/View/32669/2024-Teton-County-Fire-Code-Resolution-Signed-Current"},{"kind":"info","text":"Check the parcel/private-land status in the linked official WUI map; a ZIP does not establish inclusion, and Fire/EMS separately assigns the site-specific IR3, IR2, IR1, or does-not-apply result.","href":"https://gis.tetoncountywy.gov/portal/apps/experiencebuilder/experience/?id=0c66d130a6ee459fa3ea7f0a31d1e167"},{"kind":"check","text":"Confirm the parcel is inside the cited boundary."},{"kind":"check","text":"Check the parcel in the official hazard map."},{"kind":"check","text":"Obtain the official site hazard classification."},{"kind":"check","text":"Confirm that this project type triggers the provision."},{"kind":"check","text":"Confirm the effective date for this project."},{"kind":"check","text":"Confirm with the authority having jurisdiction."}],"requirementTraces":[{"requirementId":"iwuic-2024-class-1-2-noncombustible-deck","shortName":"IWUIC Class 1–2 noncombustible deck","href":"/requirements/iwuic-2024-class-1-2-noncombustible-deck/","applicationId":"iwuic-2024-teton-county","applicationTitle":"Unincorporated Teton County 2024 IWUIC application","state":"undocumented","constraints":[{"attribute":"assemblyRole","op":"in","value":["deck-structure","deck-surface"],"actual":"deck-surface","state":"matched"},{"attribute":"noncombustible","op":"eq","value":true,"state":"undocumented"}]}]}}}